HP LH4r hp lp 2000r and ds2100 config guide — for Microsoft Windo - Page 2

Local Storage, System software, Power distribution, Controller

Page 2 highlights

LP2KR2K2M21 Server Configuration Parameter Number of power supplies I/O slots Default boot order Local Storage Controller Driver Physical drive location Disk drives SCSI bus SCSI IDs System software Navigator CD-ROM Operating system Service pack Power distribution Layout Specification One standard, two required for redundancy Note that in configurations with more than one NetRAID controller, the second power supply is required, and not redundant. Added cards may be installed in any appropriate slot, considering the server default boot order provided below. IDE CD-ROM, FDD, PCI slot 1, PCI slot 2, PCI slot 3, embedded SCSI Embedded SCSI, or NetRAID-1M For embedded SCSI, sym_u3.sys, version 5.07.00, or later For NetRAID-1M, mraid2k.sys, version 5.20, or later (all drivers obtained from Navigator CD-ROM, version L.20.00, or later) Server internal drive bays, or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications, and any SCSI bus speed Any Version M.04.00, or later Microsoft Windows® 2000 Advanced Server Latest service pack version Redundant power distribution units (PDUs) are recommended. See power cabling diagram on page 8. Shared Storage Configuration Parameter Controller Model Number of controllers BIOS Firmware Driver NetRAID Assistant SCSI ID Channels RAID levels Logical disks Specification HP NetRAID-2M Controller, Model P3411A, or P3475A One Disabled Version H.01.08 (firmware obtained from Navigator CD-ROM, version M.04.00) Mraid2k.sys, version 5.20 (driver obtained from Navigator CD-ROM, version M.04.00) Version B.01.04 (software obtained from Navigator CD-ROM, version version M.04.00) 6, 7 Only a channel 0 connection is supported. Use of channel 1 can cause cluster failure. 1, 5, 10, 50 One per RAID array Eight, maximum, per cluster 11/15/01 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

LP2KR2K2M21
11/15/01
2
Server Configuration
Parameter
Specification
Number of power
supplies
One standard, two required for redundancy
Note that in configurations with more than one NetRAID controller, the second
power supply is required, and not redundant.
I/O slots
Added cards may be installed in any appropriate slot, considering the server
default boot order provided below.
Default boot order
IDE CD-ROM, FDD, PCI slot 1, PCI slot 2, PCI slot 3, embedded SCSI
Local Storage
Controller
Embedded SCSI, or NetRAID-1M
Driver
For embedded SCSI, sym_u3.sys, version 5.07.00, or later
For NetRAID-1M, mraid2k.sys, version 5.20, or later
(all drivers obtained from Navigator CD-ROM, version L.20.00, or later)
Physical drive location
Server internal drive bays, or HP external drive cabinet
(e.g., HP Rack Storage/12)
Disk drives
Must be HP
SCSI bus
Any HP cables that meet SCSI specifications, and any SCSI bus speed
SCSI IDs
Any
System software
Navigator CD-ROM
Version M.04.00, or later
Operating system
Service pack
Microsoft Windows
2000 Advanced Server
Latest service pack version
Power distribution
Layout
Redundant power distribution units (PDUs) are recommended.
See
power cabling
diagram
on page 8.
Shared Storage Configuration
Parameter
Specification
Controller
Model
HP NetRAID-2M Controller, Model P3411A, or P3475A
Number of controllers
One
BIOS
Disabled
Firmware
Version H.01.08
(firmware obtained from Navigator CD-ROM, version M.04.00)
Driver
Mraid2k.sys, version 5.20
(driver obtained from Navigator CD-ROM, version M.04.00)
NetRAID Assistant
Version B.01.04
(software obtained from Navigator CD-ROM, version version M.04.00)
SCSI ID
6, 7
Channels
Only a channel 0 connection is supported.
Use of channel 1 can cause cluster failure.
RAID levels
1, 5, 10, 50
Logical disks
One per RAID array
Eight, maximum, per cluster