HP LH4r hp lp 2000r and ds2100 config guide — for Microsoft Windo - Page 6

HP Netserver LP 2000r Cluster using one HP Surestore DS2100 Disk System

Page 6 highlights

LP2KR2K2M21 NOTES: 1. To connect server to DS2100 -- C7541A - 2 Meter ILT cable 2. This diagram shows using a single DS2100. You can use from one to two storage cabinets per cluster. See the next cabling diagram for a configuration using two DS2100s. connect to NetRAID-2M channel 0 only! 3. Only connect channel 0 of the NetRAID-2M to the DS2100. Using channel 1 is not supported. 4. There are no 'left'or 'right'port requirements for cabling to the DS2100. Cables can be attached to either port. 5. Connect LAN ports A for the heartbeat cluster interconnect. Use ports B for the client LAN connection. 6. Here, the DS2100 SCSI ID switch is set to B. The following addresses will be assigned to installed disks: 8, 10, 12, and 14. Setting B or C is supported. × LAN A LAN B Heartbeat - Client LAN Connection -crossover cable or equivalent SCSI Switch A B C × LAN A LAN B Heartbeat - Client LAN Connection -crossover cable or equivalent HP Netserver LP 2000r Cluster using one HP Surestore DS2100 Disk System 11/15/01 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

LP2KR2K2M21
11/15/01
6
NOTES:
1.
To connect server to DS2100 --
2.
3.
Only connect channel 0 of
the NetRAID-2M to the DS2100.
Using channel 1 is not supported.
4.
There are no ‘
left’
or ‘
right’
port
requirements for cabling to the DS2100.
Cables can be attached to either port.
This diagram shows using a
single DS2100.
You can use from
one to two storage cabinets
per
cluster.
See the next cabling
diagram for a configuration using
two DS2100s.
C7541A - 2 Meter
ILT cable
connect to
NetRAID-2M
channel 0 only!
LAN B
- Client LAN
Heartbeat
Connection
-crossover cable
or equivalent
LAN A
LAN B
- Client LAN
Heartbeat
Connection
-crossover cable
or equivalent
LAN A
5.
Connect LAN ports A for the heartbeat
cluster interconnect. Use ports B for the client
LAN connection.
6.
Here, the DS2100 SCSI ID switch is
set to
. The following addresses will be
assigned to installed disks: 8, 10, 12, and 14.
Setting B or C is supported.
B
SCSI Switch
A
B
C
×
×
HP Netserver LP 2000r Cluster using one HP Surestore DS2100 Disk System