HP LH4r hp lp 2000r and ds2100 config guide — for Microsoft Windo - Page 4
Network, Disk Drive LEDs, Disconnected SCSI cables, NetRAID-2M channels
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
Intra-Cluster (Heartbeat) LAN Configuration Parameter NIC Quantity Model Driver Specification One Embedded NIC - LAN A Hptxnt5.sys, version 4.02.27, or later (driver obtained from Navigator CD-ROM L.20.00, or later) LP2KR2K2M21 Client LAN Configuration Parameter Network Connection NIC Quantity Model Driver Specification Any LAN One Embedded NIC - LAN B or any model that is on both the HP Tested Products List and the Microsoft® Hardware Compatibility List. If the NIC used is the same type as that of the intra-cluster LAN, then the client LAN driver must be the same as that of the intra-cluster LAN. For other NICs, any vendor-supported driver. Special Notes and Warnings Disk Drive LEDs There is no hardware support in the DS2100 for disk drive failure detection or indication by disk drive LEDs (Light Emitting Diodes). A failed drive cannot be identified by an LED signal. Only disk spin-up and data access activity is indicated by a green flashing light on a disk drive LED. Disconnected SCSI cables SCSI cables must not be disconnected while both server nodes are up. Cluster failover may not occur upon a SCSI cable being disconnected at a live node. Only disconnect a SCSI cable from a server that is powered off. Also, do not disconnect a SCSI cable interconnecting two DS2100 enclosures on a live cluster because cluster failures may result from the SCSI bus not being terminated. NetRAID-2M channels When connecting the NetRAID-2M SCSI cables to the DS2100, only use NetRAID-2M channel 0. Cluster failure could result and there is a potential for data loss from connections to channel 1 and so channel 1 connections are not supported. 11/15/01 4