HP LH4r hp netserver lc 2000 netraid-4m config guide — for Micros
HP LH4r - NetServer - 256 MB RAM Manual
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
HP LH4r manual content summary:
- HP LH4r | hp netserver lc 2000 netraid-4m config guide — for Micros - Page 1
Advanced Server Cluster Configuration Guide Introduction This document defines the server cluster configurations supported by Hewlett-Packard for interconnection of two HP Netserver LC 2000 servers and up to eight HP Rack Storage/12 disk drive enclosure(s), with Microsoft® Cluster Server software - HP LH4r | hp netserver lc 2000 netraid-4m config guide — for Micros - Page 2
2.66, or later For NetRAID-1M/2M, mraid2k.sys, version 5.20, or later (all drivers obtained from Navigator CD-ROM, version L.20.00, or later) Server internal drive bays, or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications, and any SCSI bus - HP LH4r | hp netserver lc 2000 netraid-4m config guide — for Micros - Page 3
slot Network interfaces Boot device Specification PCI slot 1, NetRAID-1Si local storage controller PCI slot 5, NetRAID-4M shared storage controller PCI slot 3, Client LAN, model D5013B NIC NetRAID-1Si Microsoft® and HP Certified Server Configuration with NetRAID-1M Parameter I/O card slot Network - HP LH4r | hp netserver lc 2000 netraid-4m config guide — for Micros - Page 4
CD-ROM L.20.00, or later) Client LAN Configuration Parameter Network Connection NIC Quantity Model Driver Specification Any LAN One, minimum Any model that is on both the HP Tested Products List and the Microsoft® Hardware Compatibility List Vendor-supported driver If the NIC used is the same as - HP LH4r | hp netserver lc 2000 netraid-4m config guide — for Micros - Page 5
shared storage NetRAID-4M controllers. Each server can use up to two NetRAID-4M controllers for shared storage, yielding eight channels total. 5. Another NetRAID-1Si, -3Si, -1M, or -2M controller may be installed in each server for local storage. HP Netserver LC 2000 Cluster using HP Rack Storage - HP LH4r | hp netserver lc 2000 netraid-4m config guide — for Micros - Page 6
lc20002k4m Power Cabling to Separate Power Circuits 1/28/02 6 - HP LH4r | hp netserver lc 2000 netraid-4m config guide — for Micros - Page 7
2002 30 October 2001 15 August 2001 27 March 2001 14 March 2001 Changed heartbeat LAN requirement. Converted to new format. Added Ultra 3 certification with NetRAID-1M. Corrected NetRAID-1M/2M driver name and version. Initial draft. lc20002k4m © Copyright 2001, Hewlett-Packard Company 1/28/02
1/28/02
1
HP Netserver LC 2000
with
NetRAID-4M (HP Rack Storage/12)
Windows
°
2000 Advanced Server
Cluster Configuration Guide
Introduction
This document defines the server cluster configurations supported by Hewlett-Packard for interconnection of
two HP Netserver LC 2000 servers and up to eight HP Rack Storage/12 disk drive enclosure(s), with
Microsoft
Cluster Server software.
These configurations provide high server cluster availability and
minimize single points of failure (SPOFs).
A configuration certified and supported by both Hewlett-Packard
and Microsoft
is included, but any cluster configuration that conforms to the guidelines of this document
will be supported by Hewlett-Packard.
Deviations from the supported configurations can result in an
inoperative cluster, an operating cluster with degraded performance, or hidden SPOFs.
Therefore, deviations
are not supported.
For revision/update information on this document, refer to
Versions
on page
7
.
Cluster Configuration Elements
This section identifies the hardware components, system software, network interfaces, and power distribution
arrangement required to build an operational server cluster supported by Hewlett-Packard.
The various
server cluster elements are listed below and their associated configuration data is detailed in separate tables
and illustrations that follow.
•
Server configuration
•
Shared storage configuration
•
Microsoft
and HP certified server configuration
•
Intra-cluster (heartbeat) LAN configuration
•
Client LAN configuration
•
SCSI cabling and power distribution configuration
Server Configuration
Parameter
Specification
Server
Type
HP Netserver LC 2000, Ultra2 embedded SCSI models
Number of nodes
Two
Do not mix ultra2 and ultra3 models within a cluster.
Each node must be the
same server type, but may have different clock speeds, and main memory and
cache sizes.
Clock speed
1 GHz
This certification covers any CPU rate within 500 MHz of the certified speed.
Number of CPUs
Two
BIOS
Version range 4.06.29 PV to 4.06.30 PV
CPU cache
Any size
RAM
256 MB, minimum.
Must be HP.