HP LH4r hp netserver lc 2000 netraid-4m config guide — for Micros - Page 5
Another NetRAID-1Si, -3Si, -1M, or -2M
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
lc20002k4m NetRAID- 4M 01 2 NOTES: 1. Diagram shows that each RS/12 must be cabled to the same NetRAID-4M channel on both servers, and the NetRAID-4M controller cards must be in the same PCI slot in both servers. All cables are the same type. 2. Cabling between the servers and RS/12s can be any HP LVD SCSI (offset) cable up to 10 meters. Refer to the Cables entry of the Shared Storage table for a list of cables that can be used. 3. This diagram shows three RS/12s in use. One to four RS/12s can be used per NetRAID-4M controller (one per channel). 4. This diagram shows server PCI slot 5 used for shared storage NetRAID-4M controllers. Each server can use up to two NetRAID-4M controllers for shared storage, yielding eight channels total. 5. Another NetRAID-1Si, -3Si, -1M, or -2M controller may be installed in each server for local storage. HP Netserver LC 2000 Cluster using HP Rack Storage/12 Cabling Diagram 1/28/02 5