HP LH4r hp netserver lc 2000 netraid-4m config guide — for Micros - Page 3

Enclosure, Cables, Power distribution

Page 3 highlights

lc20002k4m Shared Storage Configuration Parameter Containers Configuration options Enclosure Disk drives Number of cabinets Model Status SCSI ID Disk SCSI IDs Cables SCSI Power distribution Layout Single-level or multi-level Must be fault-tolerant Eight, maximum, per cluster Write cache disabled Clustering enabled Domain validation enabled Specification Any HP drive supported by storage enclosure. Any combination of HP disk models is allowed in a diskset, on a SCSI channel, or in a cluster. Up to eight Rack Storage/12 D5989B, containing two D6025B SCSI controller cards, or Rack Storage/12 D5989C, containing two D6025C SCSI controller cards 5 (fixed) 0-3, 8-15 (fixed) Any two HP LVD SCSI offset cables per RS/12 from the following list: 1 meter D7131A 2.5 meter D6020A 5 meter D6982A 10 meter D6983A See SCSI cabling diagram on page 5. Redundant power distribution units (PDUs) are recommended. See power cabling diagram on page 5. Microsoft® and HP Certified Server Configuration with NetRAID-1Si Parameter I/O card slot Network interfaces Boot device Specification PCI slot 1, NetRAID-1Si local storage controller PCI slot 5, NetRAID-4M shared storage controller PCI slot 3, Client LAN, model D5013B NIC NetRAID-1Si Microsoft® and HP Certified Server Configuration with NetRAID-1M Parameter I/O card slot Network interfaces Boot device Specification PCI slot 6, NetRAID-1M local storage controller PCI slot 5, NetRAID-4M shared storage controller PCI slot 3, Client LAN, model D5013B NIC NetRAID-1M 1/28/02 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

lc20002k4m
1/28/02
3
Shared Storage Configuration
Parameter
Specification
Containers
Single-level or multi-level
Must be fault-tolerant
Eight, maximum, per cluster
Configuration options
Write cache disabled
Clustering enabled
Domain validation enabled
Enclosure
Disk drives
Any HP drive supported by storage enclosure.
Any combination of HP disk
models is allowed in a diskset, on a SCSI channel, or in a cluster.
Number of cabinets
Up to eight
Model
Rack Storage/12 D5989B, containing two D6025B SCSI controller cards, or
Rack Storage/12 D5989C, containing two D6025C SCSI controller cards
Status SCSI ID
5 (fixed)
Disk SCSI IDs
0–3, 8–15 (fixed)
Cables
SCSI
Any two HP LVD SCSI offset cables per RS/12 from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
See
SCSI cabling diagram
on page
5
.
Power distribution
Layout
Redundant power distribution units (PDUs) are recommended.
See
power cabling
diagram
on page
5
.
Microsoft
°
and HP Certified Server Configuration with NetRAID-1Si
Parameter
Specification
I/O card slot
PCI slot 1, NetRAID-1Si local storage controller
PCI slot 5, NetRAID-4M shared storage controller
Network interfaces
PCI slot 3, Client LAN, model D5013B NIC
Boot device
NetRAID-1Si
Microsoft
°
and HP Certified Server Configuration with NetRAID-1M
Parameter
Specification
I/O card slot
PCI slot 6, NetRAID-1M local storage controller
PCI slot 5, NetRAID-4M shared storage controller
Network interfaces
PCI slot 3, Client LAN, model D5013B NIC
Boot device