HP LH4r HP Netserver LXr Pro NetRAID Installation Guide - Page 20

Part 3 - Configuring the HP NetRAID Adapter

Page 20 highlights

Part 3 - Configuring the HP NetRAID Adapter In Parts 1 and 2 you installed additional hardware in your HP NetServers, setup both the HP NetServers and the Rack Storage/8 units for use in the cluster, and rack mounted the cluster hardware. In this part, you will configure the HP NetRAID Adapters you installed in Systems A and B. Configuring Your Systems NetRAID Adapter NOTE This procedure must be performed on both Systems A and B. Start with System A and then repeat the procedure on System B. 1. Ensure that no SCSI cables are connected between Systems A and B (LXr Pros) and the Rack Storage 8 cabinets. If these units are cabled now, before you are directed to cable them, the cluster configuration steps will not be performed correctly. NOTE In steps 2 and 3 you are required to take action during the bootup of System A. Review steps 2 and 3 before starting bootup so that you are prepared to take the necessary actions. 2. Turn on power to System A. During bootup (after initialization and channel scanning) check that the displayed HP NetRAID firmware version is: HP NetRAID Adapter BIOS VER S.01.00 or later. If not, perform step 3 and then see Appendix B, Updating the HP NetRAID Firmware. 3. Press Ctrl+M when the following prompt appears: Option: Experienced users may press for HP NetRAID Express Tools now. NOTE When system scanning is completed the HP NetRAID Express Tools Management menu is displayed. Express tools are management and diagnostic utilities that contain functions not available in HP NetRAID Assistant. 4. From the Management Menu, choose Disable BIOS, then Yes. HP NetRAID Express Tools displays the message, BIOS Is Currently Disabled. 5. Choose Objects|SCSI Channel. 6. Check the status of the Ultra SCSI option for each NetRAID channel. If enabled, disable the option. 7. Check that the Terminate option for each channel is set to Terminate Wide Channel. If not, change the setting accordingly. 8. Choose Objects|Adapter|. 9. Choose Cluster Mode, then Enable. 10. Choose Initiator ID. For: • System A Initiator ID to 7 • System B Initiator ID to 6 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

9
Part 3 - Configuring the HP NetRAID Adapter
In Parts 1 and 2 you installed additional hardware in your HP NetServers, setup both the HP NetServers and the
Rack Storage/8 units for use in the cluster, and rack mounted the cluster hardware. In this part, you will
configure the HP NetRAID Adapters you installed in Systems A and B.
Configuring Your Systems NetRAID Adapter
NOTE
This procedure must be performed on both Systems A and B.
Start with
System A and then repeat the procedure on System B.
1.
Ensure that
no
SCSI cables are connected between Systems A and B (LXr Pros) and the Rack Storage 8
cabinets.
If these units are cabled now, before you are directed to cable them, the cluster configuration steps will
not be performed correctly.
NOTE
In steps 2 and 3 you are required to take action during the bootup of System A.
Review
steps 2 and 3 before starting bootup so that you are prepared to take the necessary
actions.
2.
Turn on power to System A.
During bootup (after initialization and channel scanning) check that the
displayed HP NetRAID firmware version is:
HP NetRAID Adapter
BIOS VER S.01.00
or later.
If not, perform step 3 and then see
Appendix B, Updating the HP NetRAID Firmware
.
3.
Press Ctrl+M when the following prompt appears:
Option: Experienced users may press <Ctrl> <M>
for HP NetRAID Express Tools now.
NOTE
When system scanning is completed the HP NetRAID Express Tools Management menu
is displayed.
Express tools are management and diagnostic utilities that contain
functions not available in HP NetRAID Assistant.
4.
From the Management Menu, choose
Disable BIOS
, then
Yes
.
HP NetRAID Express Tools displays the message,
BIOS Is Currently Disabled.
5.
Choose
Objects|SCSI Channel.
6.
Check the status of the Ultra SCSI option for each NetRAID channel.
If enabled, disable the option.
7.
Check that the Terminate option for each channel is set to
Terminate Wide Channel.
If not,
change the setting accordingly.
8.
Choose
Objects|Adapter|
.
9.
Choose
Cluster Mode
, then
Enable
.
10.
Choose Initiator ID.
For:
System A Initiator ID to 7
System B Initiator ID to 6