HP LH4r HP Netserver LXr Pro NetRAID Installation Guide - Page 4

Storage

Page 4 highlights

System software: Navigator version Operating System Service pack G.01.00 or later Microsoft Windows NT Server 4.0, Enterprise Edition or later SP3 and hotfix "clusfixi", or later SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots: Storage HP NetServer LXr Pro Model 1 200 MHz. 2 - 4 (at least 2 are required) 1.00.09CD0L or later Any size 128 MB minimum. Must be HP. 3 Internal or external, using any controller. Must use HP disks. See Local Storage below. P4 - P6 Shared storage controller P3 or P4 - NetRAID local storage P2 - Intra-cluster (Heartbeat) LAN P1 - Client LAN All others - Any other plug-in cards. Local Physical drive location Disk drives Controller SCSI bus Shared Controller Model No. of controllers Firmware Driver NetRAID Assistant SPU I/O slot SCSI ID Channels RAID level Logical disks SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/8) Must be HP SPU embedded controller or any controller (any number, manufacturer or driver) in any available I/O slot. Use P3 or P4 for NetRAID local storage. See SPU I/O slots above. Any HP cables that meet SCSI specifications and any SCSI bus speed HP NetRAID Adapter D4943A Use with HP Rack Storage/8 (D4902A) and HP Cluster Adapter only. 1 - 2 S.01.00 2.03 A.01.09 P4 - P6 6, 7 0 and 1 only Do not use channel 2 for any purpose. 1, 5, 10, and 50 only 1 per RAID array 6 maximum per NetRAID adapter 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

2
System software:
Navigator version
G.01.00 or later
Operating System
Microsoft Windows NT Server 4.0, Enterprise Edition or later
Service pack
SP3 and hotfix "clusfixi", or later
SPU
Model
HP NetServer LXr Pro Model 1
Clock speed
200 MHz.
No. of CPUs
2 – 4 (at least 2 are required)
BIOS version
1.00.09CD0L or later
CPU cache
Any size
RAM
128 MB minimum.
Must be HP.
No. of power supplies
3
Local storage
Internal or external, using any controller. Must use HP disks.
See
Local
Storage
below.
I/O slots:
P4 – P6 Shared storage controller
P3 or P4 - NetRAID local storage
P2 – Intra-cluster (Heartbeat) LAN
P1 – Client LAN
All others - Any other plug-in cards.
Storage
Local
Physical drive location
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/8)
Disk drives
Must be HP
Controller
SPU embedded controller or any controller (any number, manufacturer or
driver) in any available I/O slot.
Use P3 or P4 for NetRAID local storage.
See
SPU I/O slots
above.
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed
Shared
Controller
Model
HP NetRAID Adapter D4943A
Use with HP Rack Storage/8 (D4902A) and HP Cluster Adapter only.
No. of controllers
1 - 2
Firmware
S.01.00
Driver
2.03
NetRAID Assistant
A.01.09
SPU I/O slot
P4 - P6
SCSI ID
6, 7
Channels
0 and 1 only
Do not use channel 2 for any purpose.
RAID level
1, 5, 10, and 50 only
Logical disks
1 per RAID array
6 maximum per NetRAID adapter