HP Latex 110 Site preparation guide - Page 11

Single phase power, Circuit breakers, Table 2-4

Page 11 highlights

Single phase power Table 2-4 Single phase line specifications Number of power cords Input voltage Input frequency Maximum load current (per power cord) Power consumption per power cord in printing mode Power consumption in ready mode Printer Curing 2 ~200-240 V +-10% (two wires and protective earth) 50 / 60 Hz 3 A 13 A 200 W 2.0 kW 70 W Circuit breakers NOTE: The circuit breakers must meet the requirements of the printer and shall be in accordance with the Electrical Code requirements of the local jurisdiction of the country where the equipment is installed. The printer requires two Power Cords that meet the following requirements. Table 2-5 Dedicated lines per SKU Dedicated line Branch circuit breaker Residual current circuit breaker 1 1 Also known as Ground Fault Circuit Interrupter (GFCI) Printer Curing Not required. Do not overload lines. Not required. Do not overload lines. Refer to Table 2-4 Refer to Table 2-4 2 poles, 16 A/20 A according to Local Laws and printer maximum load current Recommended 2 poles, 30 mA residual, at least 20 A capacity ENWW Electrical configuration 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

Single phase power
Table 2-4
Single phase line specifications
Printer
Curing
Number of power cords
2
Input voltage
~200-240 V +-10% (two wires and protective earth)
Input frequency
50 / 60 Hz
Maximum load current (per power cord)
3 A
13 A
Power consumption per power cord in
printing mode
200 W
2.0 kW
Power consumption in ready mode
70 W
Circuit breakers
NOTE:
The circuit breakers must meet the requirements of the printer and shall be in accordance with the
Electrical Code requirements of the local jurisdiction of the country where the equipment is installed.
The printer requires two Power Cords that meet the following requirements.
Table 2-5
Dedicated lines per SKU
Printer
Curing
Dedicated line
Not required. Do not overload lines.
Refer to Table 2-4
Not required. Do not overload lines.
Refer to Table 2-4
Branch circuit breaker
2 poles, 16 A/20 A according to Local Laws and printer maximum load
current
Residual current circuit breaker
1
Recommended
2 poles, 30 mA residual, at least 20 A capacity
1
Also known as Ground Fault Circuit Interrupter (GFCI)
ENWW
Electrical configuration