HP MSA2324sa HP StorageWorks 2000 G2 Modular Smart Array reference guide (5009 - Page 89
Event code reference, An event may result from one or more errors, each of which has an
View all HP MSA2324sa manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 89 highlights
B Event code reference Information in this appendix is for reference by storage administrators and technical support personnel to aid troubleshooting. An event code identifies a type of event that has occurred in the storage system, and corresponds to an event message that is recorded in the system's event log, which you can view using SMU or the CLI. You may also receive notifications, depending on your SMU event notification settings. An event may result from one or more errors, each of which has an error code. Error codes provide more information to technical support personnel about the problem that occurred on the system. (Error codes are not described in this guide.) The following table describes the events that can occur during operation. Events are listed in order by numeric event code. Recommended actions available at this time are also listed. Table 14 Event code descriptions and recommended actions Event Event type Description code Recommended action 1 Warning A disk in the specified vdisk failed. The vdisk • See Table 15. is online but not fault tolerant. If a spare is present the controller automatically uses the spare to reconstruct the vdisk. • If dynamic spares is enabled, replace the failed disk. The system automatically reconstructs the vdisk. • If dynamic spares is disabled and no spare is available, replace the failed disk and add it as a vdisk spare to the critical vdisk. 3 Critical The specified vdisk is now offline. If a spare is present the controller automatically uses the spare to reconstruct the vdisk. If no spare is available, replace the failed disk and add it as a vdisk spare to the critical vdisk. 4 Informational A disk had an uncorrectable error and the controller reassigned the block. 6 Informational Vdisk creation status. This event is logged as or warning informational if creation immediately failed, was canceled by the user, or succeeded. This event is logged as a warning if creation failed during initialization. 8 Warning A disk in a vdisk failed and the vdisk • See Table 15. changed to a critical or offline state. If a spare is present the controller automatically uses the spare to reconstruct the vdisk. • If dynamic spares is enabled, replace the failed disk. The system automatically reconstructs the vdisk. • If dynamic spares is disabled and no spare is available, replace the failed disk and add it as a vdisk spare to the critical vdisk. 9 Informational A spare disk has been used in a critical vdisk to bring the vdisk back to a fault-tolerant state. Vdisk reconstruction starts automatically. 16 Informational A global spare has been added. 18 Informational Vdisk reconstruction status. This event is or warning logged as informational if reconstruction succeeded, or as a warning if reconstruction failed. HP StorageWorks 2000 G2 Modular Smart Array Reference Guide 89