HP MSA2324sa HP StorageWorks 2000 G2 Modular Smart Array reference guide (5009 - Page 97
Advanced Network Interface Structure was, The cache data for a missing volume was
View all HP MSA2324sa manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
Table 14 Event code descriptions and recommended actions (continued) Event Event type Description code Recommended action 169 Informational The specified SES alert condition has been cleared in the enclosure indicated. This event is generated when the problem that caused event 168 is cleared. 170 Informational The last rescan indicates that the specified enclosure was added to the system. 171 Informational The last rescan indicates that the specified enclosure was removed from the system. 172 Warning The specified vdisk has been quarantined because not all of its disks are available. There are not enough disks to be fault tolerant. The partial vdisk will be held in quarantine until it becomes fault tolerant. • Ensure that all disks are latched into their slots and have power. • During quarantine, the vdisk is not visible to the host. If after latching disks into their slot and powering up the vdisk, the vdisk is still quarantined, you can manually remove the vdisk from quarantine so that the host can see the vdisk. The vdisk is still critical. When the vdisk has been removed from quarantine, event 173 is logged. 173 Informational The specified vdisk has been removed from quarantine. 174 Informational A device firmware update has completed. 175 Informational An Ethernet link has changed status (up/down). 176 Informational The error statistics for the specified disk have been reset. 177 Informational The cache data for a missing volume was purged. 181 Informational Advanced Network Interface Structure was set. The MC configuration has been changed. 182 Informational All busses have been paused. I/O will not be performed on the disks until all busses are unpaused. 183 Informational All busses have been unpaused, meaning that I/O can resume. An unpause initiates a rescan, which is also logged. 185 Informational An EMP write command has completed. 186 Informational Enclosure parameters have been set. 187 Informational The write-back cache has been enabled due to a battery state change. 188 Informational Write-back cache has been disabled due to a battery state change. 189 Informational A disk channel that was previously degraded or failed is now healthy. HP StorageWorks 2000 G2 Modular Smart Array Reference Guide 97