stats alarm <alarm-id> rate-limit
View all HP Mellanox SX1018 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 261 highlights
Rev 1.6.2 stats alarm rate-limit stats alarm rate-limit {count | reset | window } Syntax Description Default Modes/Context History Role Example Related Commands Note Configures alarms rate limit. alarm ID Alarms supported by the system, for example: • cpu_util_indiv - Average CPU utilization too high: per- cent utilization • disk_io - Operating System Disk I/O per second too high: kilobytes per second • fs_mnt - Free filesystem space too low: percent of disk space free • intf_util - Network utilization too high: bytes per second • memory_pct_used - Too much memory in use: percent of physical memory used • paging - Paging activity too high: page faults • temperature - Temperature is too high: degrees count-type Long medium, or short count (number of alarms). reset Set the count and window durations to default values for this alarm. window-type Long medium, or short count, in seconds. Short window: 5 alarms in 1 hour Medium window: 20 alarms in 1 day Long window: 50 alarms in 7 days Config 3.1.0000 monitor/admin switch (config) # stats alarm paging rate-limit window long 2000 switch (config) # show stats alarm Mellanox Technologies 261