HP Nr3600 White Paper: HP Drives Industry Standards for Rugged Computing - Page 6

IEC 801-2, Contact, Test name, Standard, Test description, Removable hard drive

Page 6 highlights

Test name Bench handling Standard HP internal Electrostatic discharge (ESD) IEC 801-2, Contact discharge; 4kV and 8kV; air discharge: 15kV Removable hard drive Handling while outside unit Bench handling specification Test description Unit is dropped on each of the 4 edges of the base of the product on a typically used bench surface. Operating mode: Each edge is dropped 25 times at 10-second intervals, from a height of 7 cm. Nonoperating mode: Each edge is dropped 50 times at 10-second intervals, from a height of 10 cm. Unit external contacts, connectors, and screws are subjected to 5 discharges per polarity per kV, first with no external power and second with external power, and then with peripherals. At ± 4kV: No noticeable effects At ± 8kV: No data or program loss; unit reboots, resets At ± 15kV: No component failure (hard error) Unit is operating, accessing disk. Removable hard drive is checked after the drive is dropped onto a typical bench surface from a height of 5 cm, 25 times, with a time interval of 5 seconds between drops. Drive is tested while removed from unit and therefore is nonoperating.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Test name
Standard
Test description
Bench handling
HP internal
Unit is dropped on each of the 4 edges of the base of the product on a
typically used bench surface.
Operating mode: Each edge is dropped 25 times at 10-second intervals,
from a height of 7 cm.
Nonoperating mode: Each edge is dropped 50 times at 10-second intervals,
from a height of 10 cm.
Electrostatic
discharge (ESD)
IEC 801-2, Contact
discharge; 4kV and
8kV; air discharge:
15kV
Unit external contacts, connectors, and screws are subjected to 5 discharges
per polarity per kV, first with no external power and second with external
power, and then with peripherals.
At ± 4kV: No noticeable effects
At ± 8kV: No data or program loss; unit reboots, resets
At ± 15kV: No component failure (hard error)
Unit is operating, accessing disk.
Removable hard drive
Handling while
outside unit
Bench handling
specification
Removable hard drive is checked after the drive is dropped onto a typical
bench surface from a height of 5 cm, 25 times, with a time interval of
5 seconds between drops.
Drive is tested while removed from unit and therefore is nonoperating.