Port 61 I/O test failed, Port 61 bit 1 not at one
View all HP Portable 486 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
103 - 03 DMA word controller test failed 104 - 01 Interrupt controller master test failed 104 - 02 Interrupt controller slave test failed 104 - 03 Interrupt controller software RTC is inoperative 105 - 01 Port 61 bit 6 not at zero 105 - 02 Port 61 bit 5 not at zero 105 - 03 Port 61 bit 3 not at zero 105 - 04 Port 61 bit 1 not at zero 105 - 05 Port 61 bit 0 not at zero 105 - 06 Port 61 bit 5 not at one 105 - 07 Port 61 bit 3 not at one 105 - 08 Port 61 bit 1 not at one Error Recommended Code Description Action 105 - 09 Port 61 bit 0 not at one Replace the processor board and retest for error codes 105 - 10 Port 61 I/O test failed 103 - xx through 114 - xx. 105 - 11 Port 61 bit 7 not at zero 105 - 12 Port 61 bit 2 not at zero 105 - 13 No interrupt generated by failsafe timer 105 - 14 NMI not triggered by failsafe timer 107 - 01 CMOS RAM test failed 107 - 02 NOVRAM failed 107 - 03 Unable to restore extended non volatile memory contents 108 - 02 CMOS interrupt test failed 108 - 03 CMOS interrupt test, CMOS not properly initialized 109 - 01 CMOS clock load data test failed