HP ProLiant 1200 SMART-2DH Array Controller Reference Guide - Page 184
indicate a defective SCSI cable. Contact your Authorized Compaq Service Provider.
View all HP ProLiant 1200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 184 highlights
H-9 POST Error Messages continued 1788 Slot x Drive Array Reports Incorrect Drive Replacement. The following SCSI drive(s) should have been replaced: SCSI Port (y): SCSI ID (x). The following SCSI drive(s) were incorrectly replaced: SCSI Port (y): SCSI ID (z). Select F1 to continue - drive array will remain disabled. Select F2 to reset configuration - all data will be lost. The drives indicated were installed in the wrong place, so they have been disabled. Reinstall the drives correctly. Press F1 to restart the computer with the drive array disabled. Run DAAD for more information. -OrPress F2 to use the drives as configured and lose all the data on them. 1789 Slot x Drive Array Physical Drive(s) Not This message indicates that previously Responding. Check cables or replace the operating drives are missing or inoperative following drives: SCSI Port (y): following a cold or warm reset. Turn off system SCSI ID (x) and check cable connections. If cables are Select F1 to continue - drive array will connected, replace the drive. Press F1 to remain disabled. restart the computer with the drive array Select F2 to failed drives that are not disabled. responding - Interim Recovery Mode will be -Or- enabled if configured for fault tolerance. If you do not want to replace the drives now, press F2. 1792 Slot x Valid Data Found in Array Accelerator. Data automatically written to drive array. While the system was in use, power was interrupted or the system was restarted while data was in the Array Accelerator memory. Power was then restored within four days, and data in the Array Accelerator was flushed to the drive array. continued NOTE: Message 1788 might also be displayed inadvertently due to a bad power cable connection to the drive or a defective SCSI cable. If this message was due to a bad power cable connection, repair the connection and press F2. If this message is not eliminated by pressing F2, run the Drive Array Advanced Diagnostics Utility. -ORIf this message was not due to a bad power cable connection, and the drive was not replaced, this could indicate a defective SCSI cable. Contact your Authorized Compaq Service Provider. SMART-2DH Array Controller Reference Guide Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002 File Name: O-APPH.DOC Last Saved On: 2/27/98 12:10 PM COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED