HP ProLiant 2500 Compaq ProLiant 2500 Family of Servers Maintenance and Servic - Page 69
Reports Valid Data, Found in Array
![]() |
View all HP ProLiant 2500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
3-17 POST Error Messages Continued Error Code Beeps Probable Source of Problem 1789-Drive Not None Cable or hard drive Responding, failure. Physical Drive Check cables or replace physical drive X. Select "F1" to continue - drive array will remain disabled. Select "F2" to fail drive(s) that are not responding - Interim Recovery Mode will be enabled if configured for fault tolerance. 1790-Disk 0 Error None Hard drive error or wrong drive type. 1791-Disk 1 Error None Hard drive error or wrong drive type. 1792-Drive Array Reports Valid Data Found in Array Accelerator. Data will automatically be written to drive array. None This indicates that while the system was in use, power was interrupted while data was in the Array Accelerator memory. Power was then restored within eight to ten days, and the data in the Array Accelerator was flushed to the drive array. Action 1. Check the cable connections. 2. If cables are connected, replace the drive. 3. If you do not want to replace the drives now, press F2. Run the System Configuration Utility and Diagnostics and correct. Run the System Configuration Utility and Diagnostics and correct. No action necessary; no data has been lost. Perform orderly system shutdowns to avoid data remaining in the Array Accelerator. Compaq ProLiant 2500 Family of Servers Maintenance and Service Guide
![](/manual_guide/products/hewlettpackard-proliant-2500-compaq-proliant-2500-family-servers-maintenance-service-guide-43cbf23/69.png)