HP ProLiant BL25p HP ProLiant BL25p Generation 2 Server Blade Maintenance and
HP ProLiant BL25p - G2 Server Manual
View all HP ProLiant BL25p manuals
Add to My Manuals
Save this manual to your list of manuals |
HP ProLiant BL25p manual content summary:
- HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 1
HP ProLiant BL25p Generation 2 Server Blade Maintenance and Service Guide Part Number 415852-003 September 2007 (Third Edition) - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 2
is a trademark of Advanced Micro Devices, Inc. Audience assumptions This guide is for an experienced service technician. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels and are familiar with weight and - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 3
self repair ...5 Parts only warranty service ...5 Illustrated parts catalog ...16 Server blade components ...16 Removal and replacement procedures 21 Required tools...21 Safety considerations ...21 Preventing electrostatic discharge ...21 Server blade warnings and cautions 21 Rack warnings - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 4
cable...62 Local administration using iLO 2 ...62 Connecting locally to a server blade with video and USB devices 63 Accessing a server blade with local KVM 63 Accessing local media devices ...64 Specifications ...66 Environmental specifications ...66 Server blade specifications ...66 Acronyms and - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 5
are also designed for customer self repair. If, however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product. NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 6
pièce défectueuse, HP se réserve le droit de vous facturer les coûts de remplacement. Dans le cas d'une pièce CSR, HP supporte l'ensemble des frais le site Web HP (http://www.hp.com/go/selfrepair). Service de garantie "pièces seules" Votre garantie limitée HP peut inclure un service de garantie "pi - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 7
Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten . Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center Customer self repair 7 - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 8
CSR-Verfahren zwingend vorgegeben. Wenn Sie den Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen Service berechnet. Reparaciones del propio cliente Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 9
worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan worden gebracht, afhankelijk van het type garantieservice voor het product. OPMERKING: Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 10
Partner voor meer informatie over het Customer Self Repair programma van HP. Informatie over Service Partners vindt u op de HP website (http://www.hp.nl/services/servicepartners). Garantieservice "Parts Only" Het is mogelijk dat de HP garantie alleen de garantieservice "Parts Only" omvat. Volgens de - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 11
entre em contato com o fornecedor de serviços local. Para o programa norte-americano, visite o site da HP (http://www.hp.com/go/selfrepair). Serviço de garantia apenas para peças A garantia limitada da HP pode incluir um serviço de garantia apenas para peças. Segundo os termos do serviço de garantia - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 12
Customer self repair 12 - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 13
Customer self repair 13 - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 14
Customer self repair 14 - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 15
Customer self repair 15 - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 16
3 Hardware and plastics kit a) Heatsink blank b) Processor air baffle c) Power converter module retainer d) Front bezel, HP ProLiant BL25p Generation 2 Server Blade Spare part number 419531-001 392613-001 419530-001 - - - - Customer self repair (on page 5) Mandatory1 Mandatory1 Mandatory1 - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 17
e) Front bezel, HP ProLiant BL45p Generation 2 Server Blade, primary* f) Front bezel, HP ProLiant BL45p Generation 2 Server Blade, secondary* g) Screws grease and alcohol pad Battery-backed write cache components a) Smart Array E200i Controller cache module, 64-MB* Spare part number - - - - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 18
are also designed for customer self repair. If, however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product. 3No-Some HP parts are not designed for customer self repair. In order to satisfy the - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 19
Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen gebracht, afhankelijk van het type garantieservice voor het product. 3No: Nee-Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 20
Illustrated parts catalog 20 - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 21
and replacement procedures Required tools You need the following items for some procedures: • T-15 Torx screwdriver (provided inside the server blade) • T-5 Torx screwdriver • HP Insight Diagnostics software ("HP Insight Diagnostics" on page 51) Safety considerations Before performing service - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 22
local occupational health and safety requirements and guidelines for manual material handling. • Get help to lift and stabilize the product during installation or removal, especially when the product is not fastened to the rails. When the server blade enclosure weighs more than 22.5 kg (50 lb), at - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 23
The area contains no user or field serviceable parts. Do not safety requirements and guidelines for manual material handling. These symbols, Server blade preparation To service any internal server blade component, power down the server blade and remove it from the enclosure. Removal and replacement - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 24
firmware, refer to the HP website (http://www.hp.com/go/support). Remove the server blade 1. Identify the proper server blade in the server blade enclosure. 2. Back up all server blade data. 3. Power down the server blade (on page 24). 4. Remove the server blade from the server blade enclosure - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 25
down the server blade (on page 24). 4. Remove the server blade (on page 24). 5. Loosen the thumbscrew on the rear of the access panel. 6. Press down on the thumb indentations, slide the access panel toward the rear of the unit about 1.25 cm (0.5 in), and lift to remove the panel. To replace the - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 26
2. Back up all server data on the hard drive. 3. Remove the hard drive. To replace the component: 1. Open the release latch and prepare the hard drive for installation. Removal and replacement procedures 26 - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 27
/LED board cable To remove the component: 1. Power down the server blade (on page 24). 2. Remove the server blade (on page 24). 3. Remove the access panel ("Access panel" on page 25). 4. Open the flip-top compartment. 5. Remove the power button/LED board cable. Removal and replacement procedures 27 - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 28
28). 5. Remove the two T-5 screws and the power button/LED board. To replace the component, reverse the removal procedure. Front bezel To remove the component: 1. Power down the server blade (on page 24). 2. Remove the server blade (on page 24). 3. Remove the access panel ("Access panel" on page 25 - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 29
air baffle To remove the component: 1. Power down the server blade (on page 24). 2. Remove the server blade (on page 24). 3. Remove the access panel ("Access panel" on page 25). 4. Remove the processor air baffle. To replace the component, reverse the removal procedure. IMPORTANT: To ensure - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 30
down the server blade (on page 24). 2. Remove the server blade (on page 24). 3. Remove the access panel ("Access panel" on page 25). 4. Remove the processor air baffle ("Processor air baffle" on page 29). 5. Disconnect the fan cables. 6. Remove the fan assembly. To replace the component, reverse - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 31
30). 6. Disconnect the hard drive backplane power and data cable. To replace the component, reverse the removal procedure. Hard drive backplane To remove the component: 1. Power down the server blade (on page 24). 2. Remove the server blade (on page 24). 3. Remove all hard drive blanks ("Hard drive - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 32
, reverse the removal procedure. DIMMs To remove the component: 1. Power down the server blade (on page 24). 2. Remove the server blade (on page 24). 3. Remove the access panel ("Access panel" on page 25). 4. Remove the DIMM. To replace the component, reverse the removal procedure. Removal and - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 33
panel ("Access panel" on page 25). 4. Remove the FC mezzanine. To replace the component, reverse the removal procedure. NIC mezzanine To remove the component: 1. Power down the server blade (on page 24). 2. Remove the server blade (on page 24). 3. Remove the access panel ("Access panel" on page - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 34
procedure. HP Smart Array E200i Controller battery To remove the component: 1. Power down the server blade (on page 24). 2. Remove the server blade (on page 24). 3. Remove the access panel ("Access panel" on page 25). 4. Remove the battery housing from the server. Removal and replacement procedures - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 35
server blade (on page 24). 2. Remove the server blade (on page 24). 3. Remove the access panel ("Access panel" on page 25). 4. Remove the HP Smart Array E200i Controller battery ("HP Smart Array E200i Controller battery" on page 34). 5. Disconnect the battery cable from the cache module. To replace - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 36
the component: 1. Power down the server blade (on page 24). 2. Remove the server blade (on page 24). 3. Remove the access panel ("Access panel" on page 25). 4. Disconnect the battery cable from the cache module. 5. Remove the cache module. To replace the component, reverse the removal procedure - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 37
the component: 1. Power down the server blade (on page 24). 2. Remove the server blade (on page 24). 3. Remove the access panel ("Access panel" on page 25). 4. Remove the processor air baffle ("Processor air baffle" on page 29). 5. Remove the heatsink. To replace the heatsink: 1. Use the alcohol - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 38
panel. 5. Install the server blade. Processor To remove the component: 1. Power down the server blade (on page 24). 2. Remove the server blade (on page 24). 3. Remove the access panel ("Access panel" on page 25). 4. Remove the heatsink ("Heatsink" on page 37). Removal and replacement procedures 38 - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 39
the component: CAUTION: The pins on the processor socket are very fragile. Any damage to them may require replacing the system board. CAUTION: Failure to completely open the processor locking lever prevents the processor from seating during installation, leading to hardware damage. IMPORTANT: Be - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 40
processor installation tool with the socket and install the processor. CAUTION: The processor is designed to fit one way into the socket. Use the alignment guides on the processor and socket to properly align the processor with the socket. Removal and - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 41
of the processor in one of the following patterns to ensure even distribution: CAUTION: The heatsink thermal interface media is not reusable and must be replaced if the heatsink is removed from the processor after it has been installed. Removal and - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 42
fire or water. • Replace only with the spare designated for this product. To remove the component: 1. Power down the server blade (on page 24). 2. Remove the server blade (on page 24). 3. Remove the access panel ("Access panel" on page 25). 4. Identify the battery location ("System board components - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 43
to its default configuration. After replacing the battery, reconfigure the system through RBSU. To replace the component, reverse the removal procedure. Power converter module To remove the component: 1. Power down the server blade (on page 24). 2. Remove the server blade (on page 24). 3. Remove the - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 44
4. Remove the power converter module. To replace the component, reverse the removal procedure. Power converter module retainer To remove the component: 1. Power down the server blade (on page 24). 2. Remove the server blade (on page 24). 3. Remove the access panel ("Access panel" on page 25). - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 45
the server blade (on page 24). 2. Remove the server blade (on HP Smart Array E200i Controller battery ("HP Smart Array E200i Controller battery" on page 34). 14. Remove the HP Smart Array E200i Controller battery cable ("HP Smart Array E200i Controller battery cable" on page 35). 15. Remove the HP - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 46
20. Using your fingers, remove the processor from the failed system board. 21. Disengage the power connector from the chassis. Retain the thumbscrews for future use. Removal and replacement procedures 46 - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 47
22. Remove the system board. To replace the system board: 1. Install the spare system board in the server blade before installing the processor. 2. Install the power connector onto the chassis. 3. Prepare the processor socket on the spare system board: Removal and replacement procedures 47 - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 48
Use the alignment guides on the processor and socket to properly align the processor with the socket. Refer to the server blade hood label for specific instructions. CAUTION: Always install the processor parallel to the system board to avoid damage to the pins. Removal and replacement procedures 48 - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 49
of the processor in one of the following patterns to ensure even distribution: CAUTION: The heatsink thermal interface media is not reusable and must be replaced if the heatsink is removed from the processor after it has been installed. Removal and - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 50
the failed system board. 11. Install the access panel. 12. Install the server blade. 13. Power up the server blade. After you replace the system board, you must re-enter the server serial number and the product ID. 1. During the server startup sequence, press the F9 key to access RBSU. 2. Select the - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 51
select the HP ProLiant Servers Troubleshooting Guide: • The server-specific Documentation CD • The Business Support Center on the HP website (http://www.hp.com/support). Navigate to the server technical support page. Under self-help resources, select ProLiant Troubleshooting Guide. • The Technical - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 52
NOTE: The current version of SmartStart provides the memory spare part numbers for the server blade. To download the latest version, see the HP website (http://www.hp.com/support). Integrated Management Log The IML records hundreds of events and stores them in an easy-to-view form. The IML - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 53
not available. Specifically, HP provides legacy USB functionality for: • POST • RBSU • Diagnostics • DOS • Operating environments which do not provide native USB support For more information on ProLiant USB support, refer to the HP website (http://h18004.www1.hp.com/products/servers/platforms/usb - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 54
the front of the rack and physical access to secure data. For additional security, external USB functionality can be disabled through RBSU. Disabling external USB support in RBSU disables the USB connectors on the local I/O cable. Internal USB functionality is unaffected. Diagnostic tools 54 - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 55
Component identification Front panel LEDs Item LED description 1 UID 2 Health 3 NIC 1* 4 NIC 2* 5 NIC 3* Status Blue = Identified Blue flashing = Active remote management Off = No active remote management Green = Normal Green flashing = Booting Amber flashing = Degraded condition Red - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 56
(auxiliary power available) Off = Off * Actual NIC numeration depends on several factors, including the operating system installed on the server blade. Front panel components Item Description 1 Power On/Standby button 2 I/O port* 3 Hard drive bay 1 4 Hard drive bay 2 * The I/O port is - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 57
application. The drive is operating normally, and it has been selected by a management application. A predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is online, but it is not active currently. Do not remove the drive. Removing a drive may - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 58
is active, but a predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is active, and it is operating mezzanine connector System maintenance switch (SW4) Processor 2 memory bank D Processor 2 memory bank C DIMM slots 5-8 Processor socket 2 Fan - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 59
18 19 Description DIMM slots 1-4 Processor 1 memory bank A Processor 1 memory bank B Hard drive backplane data cable connector Hard drive backplane power cable connector System battery Smart Array E200i Controller cache module DIMM slot numbering Item 1 2 3 4 5 6 7 8 Description DIMM slot 5 DIMM - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 60
Position Function Default 4 Reserved Off 5* Password disabled Off 6* Reset configuration Off 7 Reserved Off 8 Reserved Off *To access redundant ROM, set S1, S5, and S6 to ON. Internal USB connector For more information, see "Internal USB functionality (on page 54)." Local I/O - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 61
port on the server blade front panel For connecting a video monitor For connecting a USB device For connecting a USB device For trained personnel to connect a null-modem serial cable and perform advanced diagnostic procedures For connecting an Ethernet to the server blade iLO interface from a client - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 62
enables the user to perform server blade administration, configuration, and diagnostic procedures in two ways: • Connecting locally to the server blade iLO 2 interface • Connecting video and USB devices directly to the server blade Local administration using iLO 2 To connect locally to iLO 2 with - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 63
guidelines: • Completely log out of the current iLO 2 session before disconnecting from the iLO 2 port. Do not remove the local I/O cable when the UID LED is flashing. • Always squeeze the locking buttons on the side of the server blade connector before disconnecting from the I/O port. Failure - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 64
this configuration, a USB hub is not necessary. To connect additional devices, use a USB hub. 1. Connect the local I/O cable to the server blade ("Local administration using iLO 2" on page 62). 2. Connect the video connector to a monitor. 3. Connect a USB mouse to one USB connector. 4. Connect a USB - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 65
NOTE: Use a USB hub when connecting a USB diskette drive and/or USB CD-ROM drive to the server blade. The USB hub provides additional connections. Item 1 2 3 4 5 6 Description Local I/O cable Monitor USB hub USB CD-ROM drive or USB diskette drive USB keyboard USB mouse Cabling 65 - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 66
maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa. Server blade specifications Specification Height Depth Width Weight (maximum) Value 4.29 cm (1.69 in) 71.1 cm (28.00 in) 26.14 cm (10.29 in) 6.79 kg - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 67
BBWC battery-backed write cache CSR Customer Self Repair DIMM dual inline memory module ESD electrostatic discharge FC Fibre Channel HBA host bus adapter HTTP hypertext transfer protocol I/O input/output iLO 2 Integrated Lights-Out 2 IML Integrated Management Log ISEE Instant Support Enterprise - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 68
LED light-emitting diode NIC network interface controller OSEM Open Services Event Manager PSP ProLiant Support Pack RBSU ROM-Based Setup Utility ROM read-only memory SAS serial attached SCSI SATA serial ATA SIM Systems Insight Manager SMTP Simple Mail Transfer Protocol UID unit identification UPS - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 69
HP Instant Support Enterprise Edition 52 HP ProLiant Essentials Foundation Pack 52 HP Systems Insight Manager, overview 52 16, 31 I I/O port 56, 60, 62, 63 illustrated parts catalog 16 iLO 2 (Integrated Lights-Out 2) 24, 62 IML (Integrated Management Log) 52 Insight Diagnostics 51 Instant Support - HP ProLiant BL25p | HP ProLiant BL25p Generation 2 Server Blade Maintenance and - Page 70
LEDs 57 serial connector 60 server blade removal 24 server blade specifications 66 signal connector 57 Smart Array E200i Controller components 16 specifications 66 specifications, environmental 66 standard NIC mezzanine 16, 51 static electricity 21 symbols on equipment 23 system battery 16, 42, 58
Part Number 415852-003
September 2007 (Third Edition)
Maintenance and Service Guide
HP ProLiant BL25p Generation 2 Server Blade