Error ID: 50049 - Motion - Dual Z-Axes are not synchronized Calibrate the Limit Sensor. 1. Move the Z to 112mm from the Table. 2. On the Control tools set 112000 and choose Absolute. 3. Calibrate the sensor bracket till the Flags (NOT, HP) turn on. 4. Do it on both sides Rear and Front. FB10000 Error Messages Troubleshooting 112000 Top Flowchart 12