HP Scitex FB10000 Geffen TS Error 50049 - Page 12
Calibrate the Limit Sensor., Do it on both sides Rear and Front.
![]() |
View all HP Scitex FB10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Error ID: 50049 - Motion - Dual Z-Axes are not synchronized Calibrate the Limit Sensor. 1. Move the Z to 112mm from the Table. 2. On the Control tools set 112000 and choose Absolute. 3. Calibrate the sensor bracket till the Flags (NOT, HP) turn on. 4. Do it on both sides Rear and Front. FB10000 Error Messages Troubleshooting 112000 Top Flowchart 12
![](/manual_guide/products/hewlettpackard-scitex-fb10000-geffen-ts-error-50049-d4fe977/12.png)
Error ID: 50049 - Motion - Dual Z-Axes are not synchronized
FB10000 Error Messages Troubleshooting
12
Calibrate the Limit Sensor.
1.
Move the Z to 112mm from the Table.
2.
On the Control tools set 112000 and choose Absolute.
3.
Calibrate the sensor bracket till the Flags (NOT, HP) turn on.
4.
Do it on both sides Rear and Front.
112000
Top
Flowchart