HP Scitex FB10000 Geffen TS Error 50049 - Page 9

Check test points B, C, D with the Jig

Page 9 highlights

Error ID: 50049 - Motion - Dual Z-Axes are not synchronized FB10000 Error Messages Troubleshooting Flowchart Top 12. Check test points B, C, D with the Jig 13. The tolerance is 0.00±0.05 from the measurement in test point A. 14. If the Z axis is not parallel - calibrate it. (See procedure PN XXX -TBD- being translated). 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

Error ID: 50049 - Motion - Dual Z-Axes are not synchronized
FB10000 Error Messages Troubleshooting
9
12.
Check test points B, C, D with the Jig
13.
The tolerance is 0.00±0.05 from the measurement in test point A.
14.
If the Z axis is not parallel - calibrate it. (See procedure PN XXX –TBD- being translated).