HP Scitex FB10000 Geffen TS Error 50049 - Page 7
With the Jig attached, set the gauge to 0., The testing points are A, B, C
![]() |
View all HP Scitex FB10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
Error ID: 50049 - Motion - Dual Z-Axes are not synchronized 7. Use the relevant jig for the Z calibration. FB10000 Error Messages Troubleshooting 8. The testing points are A, B, C, D - A point is the reference and starting point. Top 9. With the Jig attached, set the gauge to 0. 7 Flowchart
![](/manual_guide/products/hewlettpackard-scitex-fb10000-geffen-ts-error-50049-d4fe977/7.png)
Error ID: 50049 - Motion - Dual Z-Axes are not synchronized
FB10000 Error Messages Troubleshooting
7
7.
Use the relevant jig for the Z calibration.
8.
The testing points are A, B, C, D – A point is the reference and starting point.
9.
With the Jig attached, set the gauge to 0.
Top
Flowchart