HP Scitex FB10000 Geffen TS Error 67005 - Page 3

E.S. button is faulty or cable CX161-03420 connecting E.S. button to B&R module is disconnected

Page 3 highlights

Error ID: 67005: Safety - Emergency stop pressed - Unloader (bridge side) FB10000 Error Messages Troubleshooting The Unloader (bridge side) emergency stop button was pressed 1. Release the Unloader (bridge side) emergency stop button. 2. Press the Reset (blue) button on the operator console. During the Reset process, the blue LED will blink. 3. Tap Get Ready to continue 4. If the error message persists, check wiring between the E.S. button and the 2SDI1 B&R module. WARNING! High Voltage System! Do not touch any wiring while system is UP! From this stage and on, only an HP certified electrician may perform the tests. E.S. button is faulty or cable CX161-03420 connecting E.S. button to B&R module is disconnected Top 1. Go to the REC cabinet and check LEDs SI 11 and SI 12 in the 2SDI1 B&R Safety Module. Flowchart • • In normal operation, both LEDs should be turned on (light green). • In case of error in one of the channels, one of the LEDs turns off. • In case of error in both channels, both LEDs turn off. • If all of LEDs are turned off, this might indicate a connection problem between the B&R PLC and the Safety B&R module [X20SI9100]. 2. If this is the case, check the connections and strengthen them as required. 3. Check the E.S. button and the cable connecting it to the Safety B&R module (in the REC). 4. To check the E.S. button with its wire, disconnect 2SDI-SI 11(16) and 2TBM5(2) wires and check continuity between their ends. Note: When the E.S. button is in the released position, you should get continuity between the two wires (normally closed). 5. Repeat steps 3 to 4 with the second couple of wires - 2SDI1-SI 12(26) and 2TBM7(2). 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Error ID: 67005: Safety - Emergency stop pressed - Unloader (bridge side)
FB10000 Error Messages Troubleshooting
3
The Unloader (bridge side) emergency stop button was pressed
1.
Release the Unloader (bridge side) emergency stop button.
2.
Press the Reset (blue) button on the operator console. During the Reset process, the blue LED will blink.
3.
Tap Get Ready
to continue
4.
If the error message persists, check wiring between the E.S. button and the 2SDI1 B&R module.
WARNING!
High Voltage System! Do not touch any wiring while system is UP!
From this stage and on, only an HP certified electrician may perform the tests.
E.S. button is faulty or cable CX161-03420 connecting E.S. button to B&R module is disconnected
1.
Go to the REC cabinet and check LEDs SI 11 and SI 12 in the 2SDI1 B&R Safety Module.
In normal operation, both LEDs should be turned on (light green).
In case of error in one of the channels, one of the LEDs turns off.
In case of error in both channels, both LEDs turn off.
If all of LEDs are turned off, this might indicate a connection problem between the B&R PLC and the Safety B&R module
[X20SI9100].
2.
If this is the case, check the connections and strengthen them as required.
3.
Check the E.S. button and the cable connecting it to the Safety B&R module (in the REC).
4.
To check the E.S. button with its wire, disconnect 2SDI-SI 11(16) and 2TBM5(2) wires and check continuity between their ends.
Note:
When the E.S. button is in the released position, you should get continuity between the two wires (normally closed).
5.
Repeat steps 3 to 4 with the second couple of wires - 2SDI1-SI 12(26) and 2TBM7(2).
Top
Flowchart