HP Scitex FB10000 Geffen TS Error 67005 - Page 4

Flowchart

Page 4 highlights

Error ID: 67005: Safety - Emergency stop pressed - Unloader (bridge side) FB10000 Error Messages Troubleshooting A B 6. If both checks show continuity, this means that the cable and the button are ok. 7. If one of the checks shows no continuity, then we should check separately the E.S. button and the cable. 8. To check the E.S. button, disassemble it in a way its contacts are visible and set it to its Released position. 9. Use a DVM to check continuity between each couple of E.S. button poles [A1-A2 & B1-B2]. Top 10. If there is continuity (normally closed) and the error persists, then the problem is not in the E.S. but in the cable. 11. To check the cable between the E.S. button and the B&R Module, check end-to-end continuity of the four wires of the cable. Flowchart 12. If the error persists, this might indicate that the B&R module itself is faulty. 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Error ID: 67005: Safety - Emergency stop pressed - Unloader (bridge side)
FB10000 Error Messages Troubleshooting
4
6.
If both checks show continuity, this means that the cable and the button are ok.
7.
If one of the checks shows no continuity, then we should check separately the E.S. button and the cable.
8.
To check the E.S. button, disassemble it in a way its contacts are visible and set it to its Released position.
9.
Use a DVM to check continuity between each couple of E.S. button poles [A1-A2 & B1-B2].
10.
If there is continuity (normally closed) and the error persists, then the problem is not in the E.S. but in the cable.
11.
To check the cable between the E.S. button and the B&R Module, check end-to-end continuity of the four wires of the cable.
12.
If the error persists, this might indicate that the B&R module itself is faulty.