HP Scitex FB10000 Geffen TS Error 67005 - Page 5

Safety B&R Module is faulty – Replace module, Upon turning on the machine

Page 5 highlights

Error ID: 67005: Safety - Emergency stop pressed - Unloader (bridge side) FB10000 Error Messages Troubleshooting Safety B&R Module is faulty - Replace module 1. Turn the machine on. 13. Measure the voltage on the four wires via 24V_gnd (24V_0) as shown below, you should get 24V in all 4 wires. Flowchart Top 14. If the error persists, this means that the B&R module is faulty and should be replaced. Note: Each B&R Safety module is comprised of three components: Base, BSU (Bus Supply Unit) module, and two (12 pins) Terminal blocks as shown below. Replacing a B&R module, means replacing the BSU which is the "heart" of the module. 15. Before replacing a B&R module, turn the machine power OFF. 16. Release the two TBs from the faulty BSU module together with their wires, as shown in the figure below. 17. Pull the BSU out of the module base and replace it by a new BSU module. 18. Plug the two TBs back into the BSU module until you hear a click. Upon turning on the machine, the R/E led will blink green once, signaling that it has detected the new module. Step 1: Press the two latches (1) on top of the two TBs (2) and unplug them from the faulty BSU module. Step 2: Press the two latches (5) on top of the BSU module (3) and unplug it from its base (4). Step 3: Plug the new BSU module (3) into its base (4). Step 4: Plug the two TBs (2) back into the BSU module (3) until you hear a click. 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Error ID: 67005: Safety - Emergency stop pressed - Unloader (bridge side)
FB10000 Error Messages Troubleshooting
5
Safety B&R Module is faulty – Replace module
1.
Turn the machine on.
13.
Measure the voltage on the four wires via 24V_gnd (24V_0) as shown below, you should get 24V in all 4 wires.
14.
If the error persists, this means that the B&R module is faulty and should be replaced.
Note: Each B&R Safety module is comprised of three components: Base, BSU (Bus Supply Unit) module, and two (12 pins)
Terminal blocks as shown below. Replacing a B&R module, means replacing the BSU which is the “heart” of the module.
15.
Before replacing a B&R module, turn the machine power OFF.
16.
Release the two TBs from the faulty BSU module together with their wires, as shown in the figure below.
17.
Pull the BSU out of the module base and replace it by a new BSU module.
18.
Plug the two TBs back into the BSU module until you hear a click.
Upon turning on the machine, the R/E led will blink green once, signaling that it has detected the new module.
Step 1: Press the two latches (1) on top of the two TBs (2)
and unplug them from the faulty BSU module.
Step 2: Press the two latches (5) on top of the BSU module
(3) and unplug it from its base (4).
Step 3: Plug the new BSU module (3) into its base (4).
Step 4: Plug the two TBs (2) back into the BSU module
(3) until you hear a click.