HP Scitex FB10000 Geffen TS Error 67014 - Page 2

Troubleshooting Flowchart, Error ID: 67014: Safety - Unloader door is open

Page 2 highlights

Error ID: 67014: Safety - Unloader door is open Troubleshooting Flowchart FB10000 Error Messages Troubleshooting Troubleshooting Flowchart for error messages 67014 Valid for 67013 - 67022 Safety interlocks Check the X20SI9100 pulses ouput Yes Is there More than 1 interlock OFF in this module? No Is the door open? No Check interlock Yes alignment Close the door and press the Reset button to continue Is the interlock properly aligned? Check Yes interlock and wiring No Adjust the interlock orientation and distance Are interlock and wiring OK? No Yes Replace interlock or interlock wiring Replace the X20SI9100 module 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Error ID: 67014: Safety – Unloader door is open
FB10000 Error Messages Troubleshooting
Troubleshooting Flowchart
Troubleshooting Flowchart
for error messages 67014
Valid for 67013 – 67022
Safety interlocks
Is there More
than 1 interlock OFF in
this module?
No
Yes
Check
the X20SI9100
pulses ouput
Is the door open?
Close the door and press the
Reset button to continue
Yes
Check interlock
alignment
No
No
Replace interlock or
interlock wiring
Replace the
X20SI9100
module
Is the interlock
properly aligned?
Adjust the interlock
orientation and
distance
No
Check
interlock and
wiring
Yes
Are interlock and
wiring OK?
Yes
2