EM-1063, Message, Probable Cause, Recommended, Action, Severity, firmwareDownload
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 228 highlights
22 EM-1063 EM-1063 Message , [EM-1063], ,, CRITICAL, , Blade in slot faulted because it exceeds the maximum support limit of blades with Blade IDs in the chassis. Probable Cause Indicates too many blades of a set of particular types are in the system. Recommended Remove the faulted blade. Action Severity CRITICAL EM-1064 Message , [EM-1064], ,, CRITICAL, , Blade: is being powered off (based on user configuration) upon receiving a HW ASIC ERROR, reason:. Probable Cause Indicates the blade is being powered off because a hardware (HW) application specific integrated circuit (ASIC) ERROR was detected, and you have selected to power off the problem blade when such a condition occurred. Recommended Contact the switch provider for support. Action Severity CRITICAL EM-1065 Message , [EM-1065], ,, WARNING, , SSAS Virtualization Services are not available due to incompatibility between the FOS and SAS versions. Probable Cause Indicates the version of either the control processor firmware (CFOS) or the blade processor firmware (BFOS) is not compatible with the Storage Application Services (SAS) or other application firmware versions. Recommended Upgrade the FOS firmware or the SAS firmware with the firmwareDownload command. Refer to the Action release notes for a compatible version of firmware. Severity WARNING EM-1066 Message , [EM-1066], ,, INFO, , SAS Virtualization Services are now available . 158 Fabric OS Message Reference 53-1001338-01