HP StorageWorks 1606 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 415
FW-1426, Severity, Message, Probable Cause, switchStatusPolicySet, Recommended, Action
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 415 highlights
42 FW-1426 Severity INFO FW-1426 Message , [FW-1426], ,, WARNING, , Switch status change contributing factor Power supply: bad, absent. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty or missing power supplies is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Replace the faulty or missing power supply. Action Severity WARNING FW-1427 Message , [FW-1427], ,, WARNING, , Switch status change contributing factor Power supply: bad. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty power supplies is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Replace the faulty power supply. Action Severity WARNING FW-1428 Message , [FW-1428], ,, WARNING, , Switch status change contributing factor Power supply: absent. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of missing power supplies is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Replace the missing power supply. Action Severity WARNING FW-1429 Message , [FW-1429], ,, WARNING, , Switch status change contributing factor: Power supplies are not redundant. Fabric OS Message Reference 345 53-1001338-01