- HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 1
53-1000436-01 15 Jun 2007 Fabric OS Command Reference Manual Supporting Fabric OS v5.3.0 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 2
or service names are or may be trademarks or service marks of, and are used to identify, products or services of code, please visit http:// www.brocade.com/support/oscd. Export of technical data contained in this Communications Systems, Inc. 1745 Technology Drive San Jose, CA 95110 Tel: 1-408-333 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 3
53-0000519-09 Manual September 1999 May 2000 December 2000 July 2001 December 2001 March 2002 September 2002 April 2003 April 2003 May 2003 July 2003 August 2003 October 2003 Excluding edits and commands updated to support the SilkWorm 3250, 3850, and 24000 switches, added 3 commands - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 4
Manual Fabric OS Command Reference Manual Fabric OS Command Reference Manual 53-0000519-12 53-1000240-01 Fabric OS Command Reference 53-1000436-01 Manual Chapter 2, "Fabric OS Commands," content to Structured FrameMaker format to support XML delivery of command content (due to this process and a - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 5
Contents About This Document How This Document Is Organized xv Supported Hardware and Software xvi What's New in This Document xvii Document Conventions xxi Additional Information 39 authUtil 40 backplaneTest 42 backport 44 bannerSet 46 Fabric OS Command Reference Manual i 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 6
chipRegShow 83 cmemRetentionTest 84 cmiTest 86 configDefault 88 configDownload 90 configShow 94 configUpload 97 configure 100 crossPortTest 107 dataTypeShow 110 ii Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 7
141 dnsConfig 142 enclosureShow 143 errClear 145 errDelimiterSet 146 errDump 147 errFilterSet 148 errModuleShow 149 errShow 150 exit 151 fabPortShow 152 Fabric OS Command Reference Manual iii 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 8
fcpProbeShow 191 fcpRlsShow 192 fcrbcastconfig 193 fcrChipTest 194 fcrConfigure 196 fcrDisable 197 fcrEnable 198 fcrFabricShow 199 fcrLsanCount 200 fcrLsanMatrix 201 iv Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 9
253 fwAlarmsFilterShow 254 fwClassInit 255 fwConfigReload 256 fwConfigure 257 fwFruCfg 261 fwHelp 262 fwMailCfg 263 fwPortDetailShow 265 fwSamShow 268 fwSet 269 Fabric OS Command Reference Manual v 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 10
iscsiCfg 311 iscsiChipTest 319 iscsiHelp 320 iscsiPathTest 322 iscsiPortCfg 323 iscsiSessionCfg 326 iscsiswcfg 328 iscsiTargetName 330 islShow 331 isnscCfg 332 vi Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 11
372 myId 373 nbrStateShow 374 nbrStatsClear 375 nodeFind 377 nsAliasShow 379 nsAllShow 382 nscamShow 383 nsShow 385 nsZoneMember 388 passwd 391 Fabric OS Command Reference Manual vii 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 12
pkiRemove 439 pkiShow 440 policy 441 portAlpaShow 444 portBufferShow 445 portCamShow 447 portCfg 449 portCfgDefault 455 portCfgEPort 456 portCfgEXPort 457 viii Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 13
499 portLogPdisc 500 portLogReset 501 portLogResize 502 portLogShow 503 portLogShowPort 508 portLogTypeDisable 509 portLogTypeEnable 510 portLoopbackTest 511 portMirror 514 portName 517 Fabric OS Command Reference Manual ix 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 14
563 secHelp 565 secModeDisable 566 secModeEnable 567 secModeShow 572 secNonFCSPasswd 573 secPolicyAbort 574 secPolicyActivate 575 secPolicyAdd 576 secPolicyCreate 579 secPolicyDelete 582 x Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 15
620 slotShow 621 slTest 623 snmpConfig 625 snmpMibCapSet 631 snmpMibCapShow 633 spinFab 635 spinJitter 638 spinSilk 641 sramRetentionTest 645 statsClear 647 Fabric OS Command Reference Manual xi 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 16
syslogdIpRemove 691 syslogdIpShow 692 sysShutdown 693 systemVerification 695 tempShow 697 timeout 698 topologyShow 699 traceDump 701 trackChangesHelp 702 trackChangesSet 703 xii Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 17
Advanced Performance Monitoring Commands 746 Secure Fabric OS Commands 747 Exclusive Primary FCS Commands Commands Exclusive to the Primary FCS 749 Fabric OS Command Reference Manual xiii 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 18
Control Processor Commands Commands Supported on the Standby CP 753 Chapter 6 supportShow Reference supportShow Control Commands 755 supportShow Command Groups 756 Proc Entry Information Displayed 758 Appendix A RBAC Command Availability xiv Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 19
Document This document is a command reference manual written to help system administrators and technicians operate, maintain, and troubleshoot SAN products. "About This Document" contains the following sections: • "How This Document Is Organized," next • "Supported Hardware and Software" on page xvi - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 20
includes information specific to the new and changed functionality or support in the software from Brocade Fabric OS v5.0.1 to 5.3.0 supporting the following platforms: • Brocade 200E switch • Brocade 3250 switch • Brocade 3850 switch • Brocade 3900 switch • Brocade 4100 switch • Brocade 4900 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 21
What's New in This Document • New commands that were added since this document was last released: - ipfilter - iscsiswcfg - fastwritecfg - fcrLsanCount - fcrLsanMatrix Fabric OS Command Reference Manual xvii 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 22
- firmwareDownloadStatus - firmwareRestore - firmwareShow - fwPortDetailShow - ipAddrSet - ipAddrShow - isnscCfg - licensePort - lsanZoneShow - iscsiCfg - iscsiswcfg - myId - passwd - passwdCfg - perfAddIPMonitor - perfAddRWMonitor xviii Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 23
- syslogdIpRemove - syslogdIpShow - traceDump - tsClockServer - userConfig NOTE: FOS v5.3.0. supports the TCP/IP netstat command. Use this command to show network status, print of all netstat options, refer to the Linux man pages. Fabric OS Command Reference Manual xix 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 24
• Information that was deleted or deprecated since this document was last released: - savecore - traceftp - iscsitargetname - fcrdisable - fcrenable - crossporttest xx Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 25
For readability, command names in the narrative portions of this guide are presented in mixed lettercase: for example, switchShow. In actual examples, command lettercase is all lowercase. If there are exceptions, this manual specifically notes those cases in which a command is case sensitive. NOTES - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 26
This section lists additional Brocade and industry-specific documentation that you might find helpful. BROCADE for a user ID and password. Fabric OS • Fabric OS Administrator's Guide • Fabric OS Command Reference Manual • Fabric OS MIB Reference • Fabric OS Message Reference Fabric OS Optional - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 27
• Mid-Mount Rack Kit Installation Procedure Brocade 7600 • Brocade 7600 Hardware Reference Manual • Brocade 7600 QuickStart Guide Brocade 7500 • Brocade 7500 Hardware Reference Manual • Brocade 7500 QuickStart Guide • Brocade 7500 Fan Assembly Replacement Procedure • Brocade Mid Sized Power Supply - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 28
) • Brocade 3250/3850 QuickStart Guide (for v4.x software) Brocade 200E • Brocade 200E Hardware Reference Manual (for v5.x software) For practical discussions about SAN design, implementation, and maintenance, you can obtain Building SANs with Brocade Fabric Switches through: http://www.amazon.com - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 29
Service enables Fibre Channel frames to "tunnel" through IP networks by dividing frames, encapsulating the result in IP packets on entering the tunnel, and then reconstructing them as they leave the tunnel. Fabric OS supports eight FCIP interswitch links between two Brocade switches (Brocade - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 30
Information - Technical Support contract number, if applicable - Switch model - Switch operating system version - Error numbers and messages received - supportSave command output - Detailed description of the problem and specific questions - Description of any troubleshooting steps already performed - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 31
and as much detail as possible about your issue, including the topic heading and page number and your suggestions for improvement. Fabric OS Command Reference Manual xxvii 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 32
xxviii Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 33
This chapter explains how to manage a Brocade SAN and Brocade switches and directors using the Fabric OS command line Fabric OS operations. Seven roles are supported, as defined in Table 1. Role definitions are guided by perceived common operational situations and the Manual 1 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 34
session, as indicated in the command description in this manual. Access is controlled by a switch-level password for each access level. The commands available and management of SAN events across every switch in the fabric • Management switch licenses The remainder of this guide describes each command - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 35
. It is effective for the next AAA request. The configuration applies to all switch instances in a platform supporting multiple switch domains. Customers can use centralized RADIUS servers to manage AAA services for a switch, as defined in RFC 2865. When server is a required operand, it must be - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 36
the specified RADIUS server is used. --localonly Enables the switch-local database for AAA services. Use this to select the switch-local database as the primary AAA service. --radiusonly Enables the current RADIUS configuration for AAA services. Use this to select the RADIUS configuration as the - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 37
aaaConfig 2 Primary AAA Service: Switch database Secondary AAA Service: None To change the configuration for server 192.168.233.48: switch:admin> aaaconfig --change 192.168.233.48 -p 3002 -s newsecret -t 1 See Also none Fabric OS Command Reference Manual 5 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 38
save, the changes in the transaction buffer are sent to all other switches and saved to the Defined configuration (in persistent storage). For -- "No Access": switch:admin> ad --select AD0 switch:admin> defzone --noaccess switch:admin> cfgsave 6 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 39
existing zone D,PI member types. Benefits include: • Grants port control and zoning on the switch port and the devices attached to that port. • PI can be specified as a range; zone WWN member types. Benefits include: Supports node or port WWNs. Fabric OS Command Reference Manual 7 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 40
similar to a zoneCreate operation). Provides rights to zone the devices. Provides administrative view rights to the switch port the device is connected to: for example, portShow, nsShow, and so forth; does not you issue ad --apply or ad --save. Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 41
--create ad_id -d "dev_list"-s "switch_list" Creates a new administrative domain with the specified device and switch list. Newly created Admin Domains are in an activated state. On initial creation, the ADs contain ad --apply or ad --save. Fabric OS Command Reference Manual 9 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 42
A mode flag can be used to display information from a specific configuration alone: • -m 0 to display Admin Domains in Domain aware switches and members that are not online are marked with a B or an asterisk B at the end, respectively. 10 Fabric OS Command Reference Manual 53-1000436 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 43
switch WWNs specified in AD's switch support Exchange Service Support (ESS), and therefore the Name Server cannot get the correct port range of such switches . Examples To enable AD5: switch:admin> ad --activate 5 You AD_13: switch:admin> ad --activate AD_13 To add new device members: switch:admin> - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 44
: switch:admin> ad --save You are about to save the outstanding AD membership. This action will only save the changes to Defined configuration. Any changes made will be enforced only on ad --apply. Do you want to save admin domains (yes, y, no, n): [no] y 12 Fabric OS Command Reference Manual 53 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 45
> ad --show 10 -m 1 Current AD: 255 : AD255 Defined configuration AD: 1 : AD1 Active Device WWN members: Switch port members: 21:00:00:80:e5:12:8b:37; 21:00:00:80:e5:12:8b:55; 1,0; 1,1; 1,2; 1,3; 1,4; 1,5; 1,6; 1,7; 1,8; 1,9; 1,10; 1,11; Fabric OS Command Reference Manual 13 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 46
1,3; 1,4; 1,5; 2,0**; 2,1**; 2,2**; 2,3**; 2,4**; 2,5**; Switch port members: Member is AD Unaware ** - Member does not exist 5,0*; 5,1*; 5,2*; 5,3*; 5,4*; 5,5*; 1,6; 1,7; 1,8; 1,9; 1,10; To abort the Admin Domain management transaction buffer: Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 47
AD transaction (yes, y, no, n): [no] y See Also To display the current Admin Domain transaction: switch:admin> ad --transshow Current transaction token is 26816 It is abortable switch:admin> ad --transshow There is no outstanding zoning transaction cfgSave, cfgTransShow, defZone, logout Fabric OS - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 48
mode to perform AG specific operations. Synopsis ag switch will come online with default zone access set to "No Access". In order to merge the switch to a fabric you must set the default zone to "All Access" and disable/enable the E_Port". --mapshow [N_Port] 16 Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 49
were mapped to the recovered N_Port experience failback. The remaining F_Ports are not redistributed among the online N_Ports during the failback. Fabric OS Command Reference Manual 17 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 50
Displays agmode setting for the switch Enables AG mode on the switch Disables AG mode on the switch Shows N-port Mapping Sets switch:admin> ag --show Name : switch NodeName : 10:00:00:05:1e:04:06:bb Number of Ports : 24 IP Address(es) : 10.32.173.66, fec0:60:69bc:66:205:1eff:fe36:1199 Firmware - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 51
disabled (0). switch:admin> switch:admin> ag --mapset 2 "3;4" Used to map F_Ports 3 and 4 to N_Port 17 overwriting previous mappings. switch switch:admin> ag --failoverdisable 17 Failover policy is disabled for port 17 switch:admin> ag --failovershow 17 Failover on N_Port 17 is not supported switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 52
2 ag See Also admin> ag --failbackshow 17 Failback on N_Port 17 is not supported switch:admin> ag --failbackenable 17 Failback policy is enabled for port 17 portCfgNPort, portCfgNPIVPort 20 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 53
on the specific port. Operands the fabric. switch:admin> agshow --name switch Name : Firmware Version : v1.0.0 N-Ports : 1 F-Ports : 2 Attached F-Port information: PortID Port WWN 0x010208 10:00:00:00:c9:3f:7c:86 0x01020a 10:00:00:00:c9:3f:7c:b9 Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 54
the fabric: switch:admin> agshow See Also Worldwide Name Ports Enet IP Addr Firmware Local/Remote 10:00:00:00:c9:3f:7c:86 16 10.202.90.231 v1.0.0 local 10:00:00:00:c8:3f:7c:b9 17 10.202.90.232 v1.0.0 remote portCfgNPIVPort 22 Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 55
(switch) description. The default value is "Fibre Channel Switch" on most platforms; however, the default system description value is platform specific. the system. The default value is "Field Support". Refer to the Fabric OS MIB Reference Manual for detailed sysDescr, sysLocation, and sysContact - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 56
across the fabric. Operands none Examples To reset the SNMP agent to default values: switch:admin> agtcfgdefault ***** This command will reset the agent's configuration back to factory default 5: common (ro) No trap recipient configured yet 24 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 57
Configuration Customizable MIB-II system variables: sysDescr = Fibre Channel Switch. sysLocation = End User Premise sysContact = Field Support. authTraps = 0 (OFF) SNMPv1 community and trap yet See Also agtCfgSet, agtCfgShow, snmpConfig Fabric OS Command Reference Manual 25 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 58
system (switch) description. The default value is "Fibre Channel Switch" on most platforms; however, the default system description value is platform specific. system. The default value is "Field Support". Refer to the Fabric OS MIB Reference Manual for detailed sysDescr, sysLocation, and sysContact - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 59
erases the whole line, sysDescr: [Fibre Channel Switch.] sysLocation: [End User Premise.] sysContact: [Field Support.] authTrapsEnabled (true, t, false, f): [false] SNMP community size must be between 2 and 16 - please re-enter Fabric OS Command Reference Manual 27 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 60
subnet area: [0.0.0.0] Read/Write? (true, t, false, f): [true] See Also agtCfgDefault, agtCfgShow snmpConfig, SW_v5_x.mib, "Switch Management Information & Switch Enterprise Specific Trap", RFC1157, "A Simple Network Management Protocol (SNMPv1)", RFC1213, "Management information Base for Network - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 61
default value is "Fibre Channel Switch". sysLocation The location of the system. The default value is "End User Premise". sysContact The contact information for the system. The default value is "Field Support". Refer to the Fabric OS MIB Reference Manual for detailed sysDescr, sysLocation, and - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 62
To display SNMP agent configuration information: switch:admin> agtcfgshow sysDescr = Fibre Channel Switch. sysLocation = End User Premise. sysContact = Field Support. authTraps = 0 (OFF) SNMPv1 Access host subnet area 10.32.147.255 (rw) 30 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 63
No access host configured yet No access host configured yet agtCfgDefault, agtCfgShow snmpConfig, SW_v5_x.mib, "Switch Management Information & Switch Enterprise Specific Trap", RFC1157, "A Simple Network Management Protocol (SNMPv1)", RFC1213, "Management information Base for Network Management of - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 64
to be preserved across switch reboots, it must be issued only from the primary FCS switch. Operands The following operands are of the following methods: • A switch domain and port area number pair. switch:admin> aliadd "array1", "1,2" switch:admin> aliadd "array2", "21:00:00:20:37:0c:72:51" switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 65
to represent a specific port and slot combination. Area numbers are automatically assigned to a port by the Fabric OS. You can view the Area numbers using the switchShow command. This command changes the defined configuration (see cfgShow). For the change to be preserved across switch reboots, it - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 66
. For the change to be preserved across switch reboots, it must be saved to nonvolatile this command can be issued only from the primary FCS switch. Operands This command has the following operand: "aliName" zone alias array2: switch:admin> alidelete "array2" See Also aliAdd, aliCreate, - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 67
. Examples Remove a World Wide Name from "array1": switch:admin> aliremove "array1", "3,5" switch:admin> aliremove "array1", "21:00:00:20:37:0c:76:8c" switch:admin> aliremove "array1", "0xEF" See Also aliAdd, aliCreate, aliDelete, aliShow Fabric OS Command Reference Manual 35 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 68
enabled, this command can be issued only from the primary FCS switch. Operands This command has the following optional operands: "pattern" description of this display. Examples To display all zone aliases beginning with "arr": switch:admin> alishow "arr*" alias: array1 21:00:00:20:37:0c:76:8c - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 69
discussion is beyond the scope of this manual. The default parameters are optimal for most SAN applications; typical customers do not need to use this command. When used with no arguments, this command displays a list of APT policies supported on this switch, as well as the current policy. This - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 70
switch:admin> aptpolicy 1 Policy updated successfully. switch:admin> switchenable switch:admin> aptpolicy Current Policy: 1 3: Default Policy 1: Port Based Routing Policy 3: Exchange Based Routing Policy dlsReset, dlsSet, dlsShow, switchDisable 38 Fabric OS Command Reference Manual 53 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 71
address. Option [--class] allows 1-ZONE, 2-SECURITY, 3-CONFIGURATION, 4-FIRMWARE and 5-FABRIC filters. The execution of this command is subject to configuration switch:admin> auditcfg --class 2,3 Audit filter is configured. switch:admin> auditcfg --disable Audit filter is disabled. switch:admin - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 72
DH group. --policy Sets the authentication policy to auto-active mode for a switch (SW) or a device (Dev). That means the switch initiates the authentication on all E-ports; if the connecting switch does not support the authentication, then the E-port bring up will continue without authentication - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 73
authutil --set -g "*" DH Group is set to 0,1,2,3,4 See Also To restart authentication for a director based switch, use the slot and port format for specifying the port number: switch:admin> authutil --authinit 0/s1, 0/2 portShow, secAuthSecret Fabric OS Command Reference Manual 41 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 74
. It assumes that all blades available on the specified switch have passed the blade diagnostics tests. This command verifies the is jCRPAT (type=17). Use dataTypeShow to display the pattern types supported with backplaneTest. -ports itemlist Specifies a list of blade ports Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 75
backplaneTest 2 DATA TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. See Also itemList Fabric OS Command Reference Manual 43 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 76
not tested if -extonly is set to 1. This command is supported only on Brocade 3250, 3850, 3900,4100, and 24000 platforms platform. It is determined by the number of front-end ports on the specific platform and the type of frame (single frame, spinfab, or spinfab 1K Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 77
only one burst of frames to each link. Examples To test for backend ASIC pair links: switch:admin> backport -ports 1/1-1/3 -nframes 840 One moment please ... backport running... backport: Completed , portLoopbackTest, spinFab, spinSilk, txdPath Fabric OS Command Reference Manual 45 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 78
"My banner" switch:admin> bannerSet Please input context of security banner (press "." RETURN at the beginning of a newline to finish input): Do not log into this switch if you are not an authorized administrator. . See Also bannerShow 46 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 79
of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the banner for a switch: switch:admin> bannershow Banner: Do not log into this switch if you are not an authorized administrator. See Also bannerSet Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 80
for all ports in the switch. The broadcast routing information indicates on. The output from this command varies, depending on switch type. The execution of this command is subject to in the switch: switch:admin> bcastShow 0x00000000 In this example, from a switch with 128 ports, the member ports - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 81
for the specified slot is displayed. Examples To enable beaconing on slot 2, display the beaconing mode, then disable it: switch:admin> bladebeacon 2 1 switch:admin> bladebeacon 2 value = 1 switch:admin> bladebeacon 2 0 See Also switchShow Fabric OS Command Reference Manual 49 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 82
each port of the blade disables. A blade cannot be disabled or enabled when the switch is disabled or when the blade itself is faulted, powered off, or running diagnostics. ENABLED See Also bladeEnable, portDisable, portEnable, switchShow 50 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 83
switch is connected to a fabric through previously disabled ports, it rejoins the fabric. If this switch remains the principal switch switch assumes the principal role, then this switch becomes a subordinate switch switch switch:admin switch:admin> bladeenable 4 slBlade 4 is being enabled...Done switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 84
2 bladeEnable See Also 6 CP BLADE 1 ENABLED 7 SW BLADE 2 ENABLED 8 UNKNOWN VACANT 9 UNKNOWN VACANT 10 UNKNOWN VACANT bladeDisable, portDisable, portEnable, switchShow 52 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 85
is a follows: slotnumber A nonzero value that specifies the slot number from which to clear burn-in errors. Examples To clear burn-in errors from slot 2. switch:admin> burninerrclear 2 See Also burninErrShow Fabric OS Command Reference Manual 53 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 86
as follows: slotnumber A nonzero value that specifies the slot number from which to display burn-in errors. Examples To display burn-in errors from slot 2: switch:admin> burninerrshow 2 See Also burninErrClear 54 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 87
power-on self-test (POST) phase II each time a switch blade is powered on. The mode becomes active as soon preserves the errors prior to returning a board for service. For multibladed products, this is the independent blade, the diagnostic burn-in level: switch:admin> burninlevel -show Burnin level - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 88
all slots are displayed. Examples To display the burn-in status for all slots: switch:admin> burninstatus Slot State Status Run 1 ABORT PASS 3 2 ABORT PASS 3 burnin burnin To display the burn-in status for slot 3: switch:admin> burninstatus --slot 3 Slot State Status Run 3 ABORT PASS - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 89
unchanged. This command cannot be executed on an enabled switch. You must first disable the switch using the switchDisable command. This command is supported only on the Brocade 3250, 3850, 3900, and 24000 DIAG-CAMSID DIAG-CAMSTAT DIAG-CANTXMIT Fabric OS Command Reference Manual 57 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 90
2 camTest Refer to the Fabric OS Message Reference for more information. See Also centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest 58 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 91
switch. You must first disable the switch using the switchDisable command. This command is supported is executed again. The firmware sets up the hardware ASICs in the switch. When all SRAMs capable switches. The ASIC-to-ASIC connection the switch, of the ports in the switch. Data received is compared - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 92
For each of the 11 possible offsets for each ASIC X in the switch: Write a 64-byte pattern in the central memory. Read X from all ASIC Y in the switch. For ASIC X, ensure: interrupt status bits set. the error type is for the next offset to test. 60 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 93
in the switch: Write a 64-byte pattern in the central memory. Read X from all ASIC Y in the switch. For all is used. For a complete list of supported data patterns, run the dataTypeShow command. Examples To test the ASIC central memory: switch:admin> centralmemorytest -ports 1/0-1/15 Running - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 94
CM_ERR_TYPE TIMEOUT Refer to the Fabric OS Message Reference for more information. camTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest 62 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 95
configuration information: switch:admin> cfgactvshow Effective configuration: cfg: c4 zone: z3 33:07:06:05:04:03:02:01 zone: z4 44:01:23:45:67:89:a0:bc 40:01:23:45:67:89:a0:bc See Also cfgClear, cfgDelete, cfgRemove, cfgSave, cfgShow Fabric OS Command Reference Manual 63 53-1000436 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 96
. For the change to be preserved across switch reboots, it must be saved to nonvolatile memory can be issued only from the primary FCS switch. Operands This command has the following operands two new zones to the configuration "Test_cfg": switch:admin> cfgadd "Test_cfg", "redzone; bluezone" - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 97
the transaction and then disable and clear the zone configuration in nonvolatile memory for all the switches in the fabric. If no current zoning configuration exists, use the cfgSave command. If n): [no] n See Also cfgDisable, cfgEnable, cfgSave Fabric OS Command Reference Manual 65 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 98
the change to be preserved across switch reboots, it must be saved to information on name and member specifications. This command requires a issued only from the primary FCS switch. Operands This command has the following a configuration containing three zones: switch:admin> cfgcreate "USA_cfg", " - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 99
. For the change to be preserved across switch reboots, it must be saved to nonvolatile memory command can be issued only from the primary FCS switch. Operands This command has the following operand: . Examples To delete a zone configuration: switch:admin> cfgdelete "USA_cfg" See Also cfgAdd - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 100
: switch:admin> cfgdisable You are about to disable zoning configuration. This action will disable any previous zoning configuration enabled. Do you want to disable zoning configuration? (yes, y, no, n): [no] y See Also cfgClear, cfgEnable, cfgSave 68 Fabric OS Command Reference Manual 53 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 101
marks. This operand is required. Examples To enable the zone configuration "USA_cfg": switch:admin> cfgenable "USA_cfg" You are about to enable a new zoning configuration. Updating flash ... See Also cfgClear, cfgDisable, cfgSave, cfgShow Fabric OS Command Reference Manual 69 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 102
configuration. For the change to be preserved across switch reboots, it must be saved to nonvolatile memory can be issued only from the primary FCS switch. Operands This command has the following operands: To remove a zone from a configuration: switch:admin> cfgremove "Test_cfg", "redzone" See - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 103
command can be issued only from the primary FCS switch. Operands none Examples To save a zone configuration: switch:admin> cfgsave You are about to save the cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgShow, cfgTransAbort, cfgTransShow Fabric OS Command Reference Manual 71 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 104
this configuration. The effective configuration is built when a specific zone configuration is enabled and all error checking has been on SW1 using the cfgCreate or zoneCreate commands. From another switch, SW2, in the fabric, execute a transaction-closing command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 105
zone configurations that start with "Test": switch:admin> cfgshow "Test*" cfg: Test1 To display all zone configuration information: switch:admin> cfgshow Defined configuration: cfg: :37:0c:71:df To display only configuration names: switch:admin> cfgshow "*" cfg: USA1 Blue_zone cfg: USA_cfg Red_zone - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 106
with the zone configuration to all switches in the fabric. Committed size is only from the primary FCS switch. Operands This command has information in non-AD255 context: switch:admin> cfgsize Zone DB max and zone database information in AD255 context: switch:admin> cfgsize Zone DB max size - - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 107
on a different switch in the fabric when this command is run, the transaction on the other switch remains open can be issued only from the primary FCS switch. Operands This command has the following operand: Examples To abort the current transaction: switch:admin> cfgtransabort See Also cfgAdd, - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 108
switch. Operands none Examples To display the current transaction: switch:admin> cfgtransshow There is no outstanding zone transactions switch want to clear all configurations? Clearing All zoning configurations... switch:admin> cfgtransshow Current transaction token is 271010736 It is abortable - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 109
the configuration data to a host so it can be used as a guide to re-establishing the configuration data in the new mode. Use the ), both CP blades should always contain firmware that supports this command. Use of earlier versions adversely affects switch operation. Because this is a disruptive - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 110
the current configuration option on a Brocade 48000 director and to change the option: switch:admin> chassisconfig Current Option: 5 All Supported Options (With Blade ID 5 on slots 5-6 Option 1: One 128-port switch (Blade ID 4, 17 on slots 1-4, 7-10, Blade ID 5, 16 on slots 5-6) Option 5: One - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 111
chassisConfig 2 Are you sure you want to continue? (Y/N): y Current Option changed to 1 Restoring switch 0 configuration to factory defaults... done. (Telnet connection goes down at this point.) See Also configDownload, configUpload, slotShow Fabric OS Command Reference Manual 79 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 112
the chassis. In dual-domain systems, there are up to two logical switches associated with a single chassis. Operands This command has the following operand name to "dilbert": switch:admin> chassisname dilbert Please wait while committing configuration... switch:admin> chassisname dilbert See - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 113
number, in hexadecimal. 2 Object type: CHASSIS, FAN, POWER SUPPLY, SW BLADE (switch), CP BLADE (control processor), WWN (World Wide Name), or UNKNOWN. Object number: To display all FRUs for a switch: switch:user> chassisshow Chassis Backplane Revision: 1C SW BLADE Slot: 3 Fabric OS - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 114
: 2001 Day: 15 Month: 7 Year: 2001 88 days 16 days 456-777888 230-290-12370 (output truncated) See Also slotShow 82 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 115
the specified blade slot. The output of this command is for support use only. The command is supported only on Brocade 200E,3250, 3850, 3900, 4100, 24000, port registers of a chip: switch:admin> chipregshow 1/1 ffffffff See Also minisPropShow Fabric OS Command Reference Manual 83 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 116
switch. You must first disable the switch using the switchDisable command. This command is supported QUAD_RAMP, is used. For a complete list of supported data patterns, run the dataTypeShow command. Some common test on the central memory SRAMS: switch:admin> cmemretentiontest --slot 7 Running - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 117
cmemRetentionTest 2 LCMEM_ERR LCMRS_ERR LCMTO_ERR Refer to the Fabric OS Message Reference for more information. See Also camTest, centralMemoryTest, cmiTest, dataTypeShow, itemList, portLoopbackTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 85 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 118
between the ASIC transmitter and receiver. This command is supported only on Brocade 3250, 3850, 3900,and 24000 platforms all tests Examples To run a CMI test between two ASIC pairs: switch:admin> cmitest -txports 7/0-7/7 -rxports 7/8-7/15 Running cmitest Test Complete: Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 119
cmiTest 2 See Also camTest, centralMemoryTest, cmemRetentionTest, itemList, portLoopbackTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 87 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 120
and policies • User account passwords (includes all user config and all built-in accounts) • Switch PID format • Ethernet Link Mode NOTE After performing a Configdefault, it does not completely remove all system configuration to default values: 88 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 121
switch:admin> configdefault Committing Configuration ...done. See Also agtCfgDefault, configure, switchDisable, switchEnable configDefault 2 Fabric OS Command Reference Manual 89 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 122
been generated previously using configUpload, or it may have been created by a user to download only specific changes. Refer to configUpload for a description of the configuration file format. The configDownload command supports DNS names, IPv4, and IPv6 addresses. NOTE It is not required to change - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 123
to the current switch configuration. It is therefore possible to change a single configuration variable by downloading a file with a single line. All other variables remain unchanged. The configuration parameters R_A_TOV, E_D_TOV, WAN_TOV, and MAX_HOPS are interrelated. Assigning a specific value to - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 124
-up configuration for a specific switch. If using a file from a different switch, this file's configuration settings will override any current switch settings. Downloading a configuration file, which was uploaded from a different type of switch, 92 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 125
for some parameter changes to take effect. Do you want to continue [y/n]: y configDownload completed successfully. All parameters are downloaded. switch:admin> switchenable switch:admin> configDefault, configShow, configUpload, configure Fabric OS Command Reference Manual 93 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 126
Use of wildcards and other common regular expression operators is not supported. Some configuration settings will not display selectively in this manner. To display configuration settings for "passwdcfg": switch:admin> configshow "passwdcfg" passwdcfg.digits Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 127
.principalSwSelMode:0 fc4.fcIp.address:0.0.0.0 fc4.fcIp.mask:0.0.0.0 fc4.fcp.productId:FC Switch fc4.fcp.vendorId:BROCADE fcAL.alwaysSendRSCN:0 fcAL.fanFrameDisable:0 fcAL.openSendCLS:4 fcAL lcdContrast:128 (continued on next page) Fabric OS Command Reference Manual 53-1000436-01 configShow 2 95 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 128
.DomRscnToDevForSwChg.enable:0 ns.EndDeviceRscnFormat:1 oemLogo:0 perf.cfgver:1 perf.eemonchks:0 (output truncated) See Also agtCfgShow, configure, diagDisablePost, diagEnablePost, ipAddrShow, licenseShow, syslogdIpShow 96 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 129
before an upload can occur. The configUpload command supports DNS names, IPv4, and IPv6 addresses. for the password if necessary. The SSH service is also available on Unix and Windows : • The host name is not known to the switch. • The host IP address cannot be contacted. Manual 97 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 130
switch boot parameters, also known as the switch's identity. It has variables such as the switch switch OS Administrator's Guide for details 192.168.1.48". The configuration file is downloaded from this host. "user" Specifies a configuration file interactively: switch:admin> configupload Protocol ( - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 131
Password: ******** configUpload complete: All config parameters except AD Headers,SFOS, and Security parameters are uploaded from AD0 configDefault, configDownload, configShow, configure Fabric OS Command Reference Manual 99 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 132
• "System Services Settings" • "Portlog Events Enable/Disable Settings" • "Application Attributes" If executed on an enabled switch, only the changed for specific applications or operating environments but must be in agreement among all switches to allow formation of the fabric. The Switch Fabric - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 133
R_A_TOV) is displayed in milliseconds. This variable works with the variable E_D_TOV to determine switch actions when presented with an error condition. Allocated circuit resources with detected errors are any source port across the fabric. Fabric OS Command Reference Manual 101 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 134
a specific value each parameter. To reduce problems, the configuration utility validates switches to avoid the need to reboot host systems when static PID binded is used. Per-frame Route Priority In addition to the eight virtual channels used in frame routing priority, support Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 135
Channel Settings The switch enables fine-tuning for a specific application by configuring switch. TABLE 4 F_Port Login Parameters Field Type Default Range Maximum logins per switch Maximum logins per port Number Number 15*ports 126 1 to 126*ports 1 to 255 Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 136
Table . TABLE 5 RSCN Transmission Modes Field End-device RSCN Transmission Mode Domain RSCN to End-device for switch IP address or name change Type number number Default 1 0 Range 0 to 2 0 to 1 End- available. This is required for TachLite. 104 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 137
Off Descriptions of the system service settings are as follows: rstatd this information is supported by a number of operating systems that support RPC. On most UNIX-based systems (HP-UX, Irix to a switch, including sectelnet. If you are using SSH to manage a switch, you can Manual 105 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 138
Enabled Secure RPCd Callback Secure Config Upload and Download string string number boolean boolean number boolean Examples To modify configuration settings on a switch: switch:admin> configure configure System services (yes, y, no, n): [no 106 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 139
an external fiber cable into port N's receiver, thus exercising all the switch components, from the main board, to the media, to the fiber port LEDs flicker green while the test is running. The command is supported only on Brocade 200E,3250, 3850, 3900,4100, 24000, and Manual 107 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 140
with the results of portLoopbackTest and spinSilk can be used to determine which components of the switch are faulty. It is also possible to use loopback modes 3 and 5 to further loopback 3 Silkscreen loopback 5 Internal (parallel) loopback 108 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 141
more information. To run a functional test of all the ports on a switch: switch:admin> crossporttest -ports 1/0-1/15 Running crossporttest Ports Segmented (0) Executing test , portLoopbackTest, portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 109 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 142
is used. Examples To display sample data streams you can use with diagnostics: switch:admin> datatypeshow Pattern type example BYTE_FILL WORD_FILL QUAD_FILL BYTE_NOT WORD_NOT QUAD_NOT BYTE_RAMP WORD_RAMP 22222222 33333333 See Also none 110 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 143
local time. Refer to tsTimeZone for more information on time zone support. If the switch is operating in FICON Management Server mode (fmsmode), setting the it: switch:admin> date Fri Jan 29 17:01:48 UTC 2000 switch:admin> date "0227123003" Fabric OS Command Reference Manual 111 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 144
2 date See Also Thu Feb 27 12:30:00 UTC 2003 errShow, ficoncupset, ficoncupshow, portLogShow, tsClockServer, tsTimeZone, upTime 112 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 145
you want to view the debug and verbosity levels. Module names are case sensitive. This operand is optional. Examples To display information about a specific module named NS: switch:admin> dbgshow NS Module NS, debug level = 1, verbose level = 1 See Also setDbg Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 146
configuration, the local switch converts it into a cfgEnable d_efault_Cfg command. When zoning receives a cfgDisable command from a remote switch that does not support default zoning, zoning "d_efault_Cfg" zoneDelete "d_efault_Zone" 114 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 147
> cfgactvshow Effective configuration: no configuration in effect switch:admin> defzone --noaccess switch:admin> cfgsave switch:admin> defzone --show Default Zone Access Mode committed - No Access transaction - No Transaction See Also none Fabric OS Command Reference Manual 115 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 148
In this case the local switch would convert the cfgDisable command to this case the local switch would convert the issued only from the primary FCS switch. Names with the "d_efault" switch:admin> cfgactvshow Effective configuration: no configuration in effect switch:admin> defzonecreate switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 149
zone configuration. Operands None Examples To delete a default zone configuration: switch:admin> cfgactvshow Effective configuration: no configuration in effect switch:admin> defzonedelete switch:admin> cfgactvshow See Also defZoneCreate Fabric OS Command Reference Manual 117 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 150
, all blades clear. If no operand is specified, the default is to clear all bad port flags. Examples To clear the diag software flag: switch:admin> diagclearerror 8 ERROR: DIAG CLEARERR Diagnostics Errors Cleared, port: 8/31 Err# 0120041 081F See Also none 118 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 151
blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other diagnostic commands, with descriptions: switch:admin> diagcommandshow bladepropshow display mini-switch ASIC property minisregshow display contents of mini-switch registers - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 152
command to disable POST. A reboot is not required for this command to take effect. Operands none Examples To disable the POST during future power ons: switch:admin> diagdisablepost Config update Succeeded Diagnostic POST is now disabled. See Also diagEnablePost 120 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 153
of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To enable the POST during future power ons: switch:admin> diagenablepost Config update Succeeded Diagnostic POST is now enabled. See Also diagDisablePost Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 154
the FR4-18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other feature operations. This display the values of the diagnostic parameters: switch:admin> diagshowusr Name Environment USR_DILATION DIAG_USR_DLY_DILATION USR_MEMDLY - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 155
See Also USR_SEED DIAG_USR_SEED USR_SPECIAL DIAG_USR_SPECIAL (output truncated) none diagEnv 2 0x0 0x0 Fabric OS Command Reference Manual 123 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 156
limit setting. If no operand is specified, the current value is displayed. Examples To change the fail limit from 1 to 5: switch:admin> diagfaillimit -show Fail Limit is 1. switch:admin> diagfaillimit 5 Fail Limit is now 5. Config update Succeeded See Also none 124 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 157
knowledge of the underlying hardware and are intended for support personnel only. Contact support if you want to use these operands. The execution display diagnostic command information: switch:admin> diaghelp bladepropshow chippropshow Fabric OS Command Reference Manual 125 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 158
the FR4-18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other feature operations. This displayed. Examples To display the loop ID: switch:admin> diagloopid -show FL mode Loop ID is 125. See Also none 126 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 159
only on the names of the specific variables, not on their exact the command is not supported by the Brocade platform the diagnostic mode: switch:admin> diagmodeshow diag.mode OFF See Also burninLevel, setEsdMode, setGbicMode, setSplbMode Fabric OS Command Reference Manual 127 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 160
. POST mode modifies the behavior of the diagnostics daemon program to inhibit testing of switch blades when the system is first powered on or a new blade is added. then disable the POST test: switch:admin> diagpost Diagnostic POST is currently disabled. switch:admin> diagpost 1 Config update - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 161
operand to display the current mode setting. If no operand is specified, the current value is displayed. Examples To view the current retry mode value: switch:admin> diagretry -show Diagnostic Retry Mode is currently enabled. See Also none Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 162
of burn-in script to current burn-in script. Examples To set the burn-in script and mode: switch:admin> diagsetburnin --slot 1 -current existing script is: /fabos/share/switchess.sh Burnin mode is Enabled. See Also burninErrShow, diagSetCycle 130 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 163
style of option list. value is the keyword to update; the value should be specified manually in this case. Examples To update diagnostic command parameters: switch:admin> diagsetcycle switchburnin.sh -show CURRENT - KEYWORD : DEFAULT 1 - number_of_runs : 1 2 - vib : 2 10 - thermal : 10 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 164
-uports displays. The default value is 0. Examples To display diagnostic status on a switch blade: switch:admin> diagshow Diagnostics Status: Fri Feb 08 15:25:24 2002 Slot: 1 UPORTS UP 2G Auto ...... (output truncated) See Also itemList 132 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 165
18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other feature operations . Examples To enable show-time mode: switch:admin> diagshowtime Show Time mode is 0 (Disabled). switch:admin> diagshowtime 1 Config update Succeeded Show - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 166
that might prove hazardous to normal switch operation. The exact use of this flag is determined by the POST scripts and the specific test methods used. Operands This command the current skip test flags: switch:admin> diagskiptests -show Skip tests is 1. See Also none 134 Fabric OS Command - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 167
in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other are assumed. Examples To display currently running diagnostic tests: switch:admin> diagstatus Diagnostic status for slot: 1. Diag OS Command Reference Manual 135 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 168
0, Error DIAG-MANUAL1, 1, " 1 Starting switchess ... Err# 0140042 0100:101:000:001:26:39: 0x47ff (fabos): Feb 07 21:45:36 Switch: 0, Error DIAG-MANUAL1, 1, " 1 switchess: ABORT ... Err# 0140042 0100:101:000:002:26:41:1N See Also diagSetBurnin 136 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 169
policy_list -d switch_list ] Description Use this command to distribute data to a specific list of switches in the fabric. The data distributed must be from the policy sets currently supported; namely SCC Switch Connection Control Policy DCC Device Connection Control Policy PWD Password Database - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 170
FCS policy and Password database to all domains in the fabric that support the distribute feature: switch:admin> distribute -p "FCS;PWD" -d "*" To distribute the AUTH amd FCS policies to all v5.3. switches in the fabric. switch:admin> distribute -p "AUTH;FCS" -d "*" To distribute the AUTH and FCS - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 171
the fabric cannot handle occasional routing changes correctly. DLS is not supported in certain routing policies. Refer to aptPolicy for more information on To disable the dynamic load sharing option: switch:admin> dlsreset Committing configuration...done. switch:admin> dlsshow DLS is not set See - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 172
this setting. The DLS option is on by default. DLS is not supported in certain routing policies. Refer to aptPolicy for more information on routing Operands none Examples To enable the dynamic load sharing option: switch:admin> dlsset switch:admin> dlsshow DLS is set See Also aptPolicy, dlsReset, - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 173
balance. Refer to dlsSet for a description of load sharing. DLS is not supported in certain routing policies. Refer to aptPolicy for more information on routing policies. The the current DLS option setting: switch:admin> dlsshow DLS is set See Also dlsSet, dlsReset Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 174
the domain name service parameters. The domain name service parameters are the parameters for the system: switch:admin> dnsconfig Enter option 1 Display Domain Name Service (DNS) configuration 2 successfully Enter option 1 Display Domain Name Service (DNS) configuration 2 Set DNS configuration - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 175
attribute Description Use this command to display attributes of the switch enclosure. Currently, supported attributes are the vendor-specific enclosure identifier and the identifier of the enclosure interface to which the switch is attached. This command is only meaningful for the products - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 176
used by the enclosure manager. Displays whether or not the switch has a fuse. Examples See Also To display the identifier of the enclosure interface to which the switch is attached: switch:admin> enclosureShow slotid Bay 4 chassisShow 144 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 177
instances on this control processor (CP). Synopsis errclear Description Use this command to clear all internal and external error log messages for all switch instances on this CP. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 178
operand is optional. Examples To display the start and end delimiter: switch:admin> errdelimiterset delimiter start string: delimiter end string: See Also To change the start and end delimiter (with sample output): switch:admin> errdelimiterset -s "Start" -e "End" Start2003/03/10-09:54 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 179
error logs from Fabric OS versions prior to v4.2. Examples To display the error log, without pagination: switch:user> errdump Version: 4.4.0 2004/07/14-22:24:08, [HAMK-1003], 1,, INFO, switch1, See Also errDelimiterSet, errFilterSet, errShow Fabric OS Command Reference Manual 147 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 180
severity level of the message to pass through the filter. Valid values are "INFO", "WARNING", "ERROR", or "CRITICAL". Examples To display the current filter settings: switch:admin> errfilterset console: filter severity = WARNING See Also To set the filter severity level for the console - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 181
that may be in place. Operands none Examples To display a list of all defined error log modules: switch:user> errmoduleshow KT UT TRCE KTRC LOG CDR BLPU PISP PIXE EGR BL PIC PS RTE AS AUTH BLDE (output truncated) See Also errDump, errShow Fabric OS Command Reference Manual 149 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 182
error logs from Fabric OS versions prior to v4.2. Examples To display the error log, with pagination: switch:user> errshow Version: 4.4.0 2004/07/14-22:24:08, [HAMK-1003], 1,, INFO, switch1, See Also errDelimiterSet, errDump, errFilterSet 150 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 183
exit command is an accepted synonym for logout, as is typing Ctrl-D at the beginning of a line. Operands none Examples To exit from a shell session: switch:admin> exit Connection to host lost. See Also logout Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 184
received from the port 0x00000100 Port truly connected to E_Port 0x00000200 Segmented by routing code 0x00000400 fspf has completed routing 152 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 185
isolation nbrWWN Neighboring switch's WWN nbrPort Neighboring switch's port lr_tid that are connected to the same neighboring switch The execution of this command is subject ports. Examples To display fabric port information: switch:admin> fabportshow 4/14 Fabric Port Information Port: - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 186
2 fabPortShow See Also Flags: nbrWWN: nbrPort: lr_tid: red_ports: 10 11 62 63 0x280120 10:00:00:60:69:80:06:cf 5 0x1005dbd8, IDLE STATE Open commands pending No commands pending portShow 154 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 187
this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the retry count of Fabric OS commands: switch:user> fabretryshow SW_ILS E_Port ELP EFP HA_EFP DIA RDI BF FWD EMT ETP RAID GAID ELP_TMR GRE ECP 16 0 0 00 0 0 0 0 0 0 0 0 0 0 17 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 188
fails. Examples To change the number of entries: switch:admin> fabriclog -s Time Stamp Input and *Action S, P Sn, 01:08:52 2005 01:08:52.977 SCN Switch Offline A2,NA F2,NA NA NA 01: Max number of entries: 8192 switch:admin> fabriclog -r 64 Warning: This command will clear the - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 189
fabricLog 2 See Also Are your sure you want to do the resize [y/n]? y switch:admin> fabriclog -s Time Stamp Input and *Action S, P Sn,Pn Port Xid fabPortShow, fabStatsShow Fabric OS Command Reference Manual 157 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 190
mode setting: switch:admin> fabricprincipal 1 Principal Selection Mode enabled See Also To enable the mode setting and force fabric rebuild: switch:admin> fabricprincipal -f 1 Principal Selection Mode enabled (Forcing fabric rebuild) fabricShow 158 Fabric OS Command Reference Manual 53-1000436 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 191
. This field will be empty if the switch is not an FC Router of it the FC Router does not support it. The execution of this command is of four switches. "sw180" is the Principal switch. Three of the switches are configured to run IP over Fibre Channel. switch:admin> fabricshow Switch ID Worldwide - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 192
fabricshow -m Switch ID Name ENET IP Addr FC Router FC Router IP Addr Name 1: fffc01 fcr_sprint_01 10.33.59.224 160: fffca0 fcr_fd_160 0.0.0.0 10.33.59.25 fcr_meteor2 190: fffcbe fcr_mojo_6 10.33.59.32 The Fabric has 3 switches switchShow 160 Fabric OS Command Reference Manual 53 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 193
the fabric state information: switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid 11955:655 SCN Switch Online F2,NA F2,NA ACC Receive F2,P2 F2,P2 21 0x277 switch:admin> fabstateclear switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn, - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 194
fabstateresize 64 Warning: This command will clear the logs. Are your sure you want to do the resize [y/n]? y switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid See Also fabricLog, fabStateClear, fabStateShow 162 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 195
Operands none Examples To display the fabric state information: switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid 11955:655 SCN Switch Online F2,NA F2,NA NA NA 11955:657 , fabStateResize, fabricLog Fabric OS Command Reference Manual 163 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 196
the fabric. The information displays as follows: Number of times a switch domain ID has been forcibly changed Number of E_Port offline transitions Overlap: 0 Zoning: 0 E_Port Segment: 0 Licensing: 0 Disabled E_Port: 0 Platform DB: 0 164 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 197
Sec Incompatibility: 0 Sec Violation: 0 ECP Error: 0 Duplicate WWN: 0 Eport Isolated: 0 See Also fabRetryShow fabStatsShow 2 Fabric OS Command Reference Manual 165 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 198
be in place. Operands none Examples To display fabric switch state structure: switch:admin> fabswitchshow Fabric Switch State Structure Information State: D0 Stage: warm done Rdi Ports used for EFP/BF/DIA flood: (output truncated) 166 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 199
See Also supportShow fabSwitchShow 2 Fabric OS Command Reference Manual 167 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 200
that may be in place. Operands This command has the following operand: unit Specifies the fan unit number to disable. Examples To disable a fan unit: switch:admin> fandisable 1 Fan unit 1 has been disabled See Also fanEnable, fanShow 168 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 201
that may be in place. Operands This command has the following operand: unit Specify the fan unit number to enable. Examples To enable a fan unit: switch:admin> fanenable 1 Fan unit 1 has been enabled See Also fanDisable, fanShow Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 202
fan speed is displayed. The output from this command varies depending on switch type and number of fans present. The execution of this command is in place. Operands none Examples To display information on the fans in the system: switch:admin> fanshow Fan #1 is OK, speed is 2721 RPM Fan #2 is OK - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 203
command is subject to Admin Domain restrictions that may be in place. Operands Examples none To reboot the Control Processor, without executing POST on startup: switch:admin> fastboot See Also diagDisablePost, diagEnablePost, reboot Fabric OS Command Reference Manual 171 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 204
supported only for FR4-18i and Brocade 7500 systems. The blade can be configured either to support FC fastwrite or FCIP (default supported when FC fastwrite is disabled). When the blade is configured to support switch:admin Non-bladed switches will be - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 205
WARNING !!!! Disabling this feature requires power-cycling of the affected blade to take effect and may take up to 5 minutes to complete. Non-bladed switches will be rebooted. In all cases, data traffic on all the ports (FC and GbE) of the blade will be disrupted. Continue (Y,y,N,n): [ n] portcfg - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 206
be preserved across switch reboots, it FCS switch. Operands switch:admin> fazoneadd "Blue_fazone", "array3; array4; array5" To add a Fabric Assist host member to "Blue_fazone": switch :admin> fazoneadd "Blue_fazone", "H{5,6}" See Also To add another target member to "Blue_fazone": switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 207
defined with the following members "2,12; 2,14; 10:00:00:60:69:00:00:8a" would contain devices connected to switch 2, ports 12 and 14, and the device with a WWN of "10:00:00:60:69:00:00:8a" ( specified by one or more of the following methods: Fabric OS Command Reference Manual 175 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 208
"Red_fazone", "H{1,0}; loop1" switch:admin> fazoneCreate "Blue_fazone", "H{1,1}; array1; 1,2; array2" switch:admin> fazoneCreate "Green_fazone", "1,0; loop1; H{1,2}; array2" See Also fazoneAdd, fazoneDelete, fazoneRemove, fazoneShow 176 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 209
cfgEnable command. For the change to be preserved across switch reboots, it must be saved to nonvolatile memory can be issued only from the primary FCS switch. Operands This command has the following operands: fazonename a Fabric Assist zone: switch:admin> fazonedelete "Blue_fazone" See - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 210
cfgEnable command. For the change to be preserved across switch reboots, it must be saved to nonvolatile memory using can be issued only from the primary FCS switch. Operands This command has the following operands: remove "array2" from "Blue_fazone": switch:admin> fazoneremove "Blue_fazone", " - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 211
security is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operands: pattern Specify a value to search Assist zones beginning with the letters A through C: switch:admin> fazoneshow "[A-C]*" fazone: Blue_fazone 1,1; array1; 1,2; - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 212
compression processor, and GigPHY. This command is supported only on Brocade FR4-18i blades and Brocade All GbE port Examples To run all tests on slot 7 and GbE port 1: switch:admin> fcipchiptest --slot 7 -unit 1 -testtype 0 Running fcipchiptest Test Complete: fcipchiptest Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 213
See Also fcipPathTest fcipChipTest 2 Fabric OS Command Reference Manual 181 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 214
by the network processor due to the designated loopback. This command is supported only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands This slot 2 with PHY loopback sending 10 frames: switch:admin> fcippathtest --slot 2 -path 2 -nframes 10 182 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 215
might report one or more of the following: PATH_TEST_ERR PATH_TEST_CHIP_INIT_ERR PATH_TEST_IMAGE_ERR PATH_TEST_TIMEOUT_ERR PATH_TEST_HEARTBEAT_ERR PATH_TEST_INVALID_RESULT PATH_TEST_GE_PORT_ENABLE_ERR PATH_TEST_GE_PORT_DISABLE_ERR fcipChipTest Fabric OS Command Reference Manual 183 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 216
any LUN query from this switch. Examples To display the LUN information: switch:user> fclunquery Target Index: LUN information of a list of port WWNs: switch:admin> fclunquery -w 20:00:00:04:cf: switch: switch:admin> fclunquery -s The following WWNs will be used for any lun query from this switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 217
Channel Extended Link Service (ELS) Echo to understand if this is due to the device not supporting this ELS Echo request. Do not assume that the payload sent. This is useful for diagnosing data-dependent problems in the fabric link. The pattern bytes are specified as Manual 185 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 218
display one device that accepts the request and another device that does not respond to the request: switch:admin> fcping 0x020800 22:00:00:04:cf:75:63:85 Source: 0x20800 Destination: 22:00: trip min/avg/max = 0/0/0 usec gettimeofday, ping 186 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 219
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To clear the FCPD debug information log: switch:admin> fcplogclear See Also fcpLogDisable, fcpLogEnable, fcpLogShow Fabric OS Command Reference Manual 187 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 220
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To disable the FCPD debug information log: switch:admin> fcplogdisable See Also fcpLogClear, fcpLogEnable, fcpLogShow 188 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 221
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To enable the FCPD debug information log: switch:admin> fcplogenable See Also fcpLogClear, fcpLogDisable, fcpLogShow Fabric OS Command Reference Manual 189 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 222
of FCP device probing. Operands none Examples To display the FCPD debug information log: switch:admin> fcplogshow Time Stamp Event Port file&lineno arg0 arg1 arg2 arg3 arg4 22 :1 See Also fcpLogClear, fcpLogDisable, fcpLogEnable 190 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 223
to list valid ports. This operand is required. Examples To display the FCP probe information: switch:admin> fcpprobeshow 4/4 port 52 is L-Port and it is online. nodes probed: 2 successful IBM DDYF-T09170R F60N portLoginShow, portLogShow Fabric OS Command Reference Manual 191 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 224
to its slot for bladed systems. Use switchShow to list valid ports. This operand is required. Examples To display the FCP RLS information: switch:admin> fcprlsshow 2/5 0xda 0xdc link fail 0 0 loss sync 5 3 loss sig 0 0 prtc err 0 0 bad word 525 330 crc err 0 0 See Also portLoginShow - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 225
on the switch. Operands This command takes the following operands: -show Shows the current configuration on the switch. -enable actions possible. EXAMPLES To display the current configuration of the switch. switch:admin> frcbcastconfig --show Broadcast configuration is disabled for: fid - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 226
to verify the SRAM of the FPGAs. This command is supported only on Brocade FR4-18i blades and Brocade 7500 platforms. FC Router FPGA Examples To run all tests on slot 7 and FC Router FPGA 1: switch:admin> fcrchiptest --slot 7 -unit 1 -testtype 0 Running fcrchiptest Test Complete: fcrchiptest - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 227
, the test might report one or more of the following: DMA_ALLOC_FAIL DMA_READ_ABORT DMA_READ_TIMEOUT CHIP_INIT_TIMEOUT BIST_TIMEOUT BIST_FAIL See Also fcrPathTest, miniCycle, portLoopbackTest Fabric OS Command Reference Manual 195 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 228
The backbone fabric is the fabric attached to the U_Ports-for example, E/F_Ports-of this switch. The backbone fabric ID must be unique across all FC Router-connected fabrics. The See Also fosConfig, switchDisable, switchEnable, switchShow 196 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 229
service on a switch. This command is not supported in v5.3.0; instead use fosConfig. Synopsis fcrdisable Description Use this command to disable Fibre Channel (FC) routing on a switch. This command can be run while the switch an XPath OS switch is in the BB : "FC Routing service is in the process - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 230
fcrEnable Enables the FC Routing service on the switch. This command is not supported in v5.3.0; instead use fosConfig. Synopsis fcrenable Description Use this command to enable the Fibre Channel (FC) Routing service on a switch. In Fabric OS v5.1 the FC Routing service is enabled by default. In - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 231
support switch Switch Info (WWN, enet IP, name) The WWN, Ethernet IP address, and switch name of the switch attached to the EX_Port. Operands none Examples To display the FC Routers in the backbone fabric: switch FID Neighbor Switch Info (enet Switch Info (enet - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 232
limit is also displayed with command fcrresourceshow. Only 3000 or 5000 are supported as valid count. Operands If no operands are specified, this command current LSAN limit: switch:admin> fcrlsancount LSAN Zone Limit: 3000 See Also To set the new LSAN zone limit: switch:admin> fcrlsancount 5000 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 233
is saved per switch and not distributed to other FCR switches automatically. The best practice is to enter the same information for all the FCR switches in the backbone that supports this command. Using edge fabric assumes the default behavior. Fabric OS Command Reference Manual 201 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 234
switch:admin > fcrlsanmatrix --add 4 5 switch:admin >fcrlsanmatrix --add 4 7 switch:admin > fcrlsanmatrix --add 10 14 switch:admin > fcrlsanmatrix --add 10 19 To remove an entry: switch switch:admin > fcrlsanmatrix --apply To view the persistent changes: switch switch:admin > fcrlsanmatrix --fabricview - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 235
--apply switch:admin > fcrlsanmatrix --fabricview LSAN MATRIX is activated Fabric ID 1 Fabric ID 2 52 78 52 82 78 82 Default LSAN Matrix: 57 91 See Also fcrFabricShow, lsanZoneShow, fcrPhyDevShow, fcrProxyDevShow, fcrRouteShow, switchShow Fabric OS Command Reference Manual 203 53 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 236
, 0x01, 0x02, 0x05, ... CHALF_SQ0x4a, 0x4a, 0x4a, 0x4a, ... QUAD_NOT0x00, 0xff, 0x00, 0xff, ... CQTR_SQ0x78, 0x78, 0x78, 0x78, ... CRPAT 0xbc, 0xbc, 0x23, 0x47, ... 204 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 237
0x6e, 0x9a, ... This command is supported only on Brocade FR4-18i blades and 10. Examples To test slot 2 with FC Router FPGA Serdes loopback sending 10 frames: switch:admin> fcrpathtest --slot 2 -path 2 -nframes 10 Running fcrpathtest Test Complete: fcrpathtest Reference Manual 205 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 238
failover. Examples To display the physical devices relevant to this FC Router: fcr:admin> fcrphydevshow Device WWN Exists Physical PID 206 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 239
fcrPhyDevShow 2 in Fabric 2 10:00:00:00:c9:2b:6a:68 c70000 3 50:05:07:65:05:84:09:0e 0100ef 3 50:05:07:65:05:84:0b:83 0100e8 Total devices displayed: 3 See Also fcrFabricShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference Manual 207 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 240
their slots using the -r operand and try again." is displayed if all slots are used for the specified edge fabric. 208 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 241
Examples To display the persistent proxy device configuration: switch:admin> fcrproxyconfig Imported FID 002 002 002 66:77 to use slot f101h in fabric 5: switch:admin> fcrproxyconfig -s 5 00:11:22:33: 55:66:77 from its persistent slot in fabric 5: switch:admin> fcrproxyconfig -r 5 00:11:22:33:44:55 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 242
relevant to this FC Router. -f fabricid Display proxy devices in the specified fabric that are relevant to this FC Router 210 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 243
the specified port WWN. Examples To display the physical devices relevant to this FC Router: switch:admin> fcrphydevshow Device WWN Physical Exists PID in Fabric 2 10:00:00:00:c9:2b , fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference Manual 211 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 244
are not returned to the pool until the system reboots, because the phantom switch could still be accessible through other switches. Across a switch reboot, the allocation starts from the next usable WWN from the pool for the local FC Router: 212 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 245
fcrResourceShow 2 switch:Admin> fcrresourceshow Daemon Limits: LSAN Zones: LSAN Devices | 1 4 190 | 0 0 NOTE Only configured "EX/VEX" ports are displayed. See Also fcrFabricShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference Manual 213 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 246
this command displays the current link costs for all ports on the switch. The execution of this command is subject to Admin Domain restrictions that 1000 or 10000. Examples To display the cost of all EX_Ports: switch:admin> fcrrouterportcost Port Cost 7/3 1000 7/4 1000 7/9 1000 7/10 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 247
To set the cost of an EX_Port: switch:admin> fcrrouterportcost 7/10 10000 See Also switchShow, fcrRouteShow, portCfgEXPort fcrRouterPortCost 2 Fabric OS Command Reference Manual 215 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 248
between imported fabrics, creating a meta-SAN. There are FC Router ports that backbone/intermediate fabrics are currently not supported, an NR_Port provides a path to of the Principal Switch in the Dest. Fabric The World Wide Name of the principal switch in the destination Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 249
preferred domain ID when the translate domain is not active and is persistently saved. The principal switch attempts to provide the translate domain with the requested domain ID, but might not provide it the translate domain configuration: Fabric OS Command Reference Manual 217 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 250
domain created in fabric 2 that represents remote fabric 3 to a value of 8: switch:admin> fcrxlateconfig 2 3 8 xlate domain already configured, overwrite?(n) y To clear domain created in fabric 2 that represents remote fabric 3: switch:admin> fcrxlateconfig -r 2 3 xlate domain deleted See Also - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 251
"SCC:S;DCC". To set the fabric-wide policy to NULL (default) or no fabric-wide consistency, use the policy Set "". Supported policies are Switch Connection Control (SCC) and Device Connection Control (DCC). Examples To display the Fabric-Wide Consistency Policy and the accept/reject configuration - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 252
to reject distribution of SCC and DCC policy sets: switch:admin> fddcfg --localreject "SCC;DCC" Local Switch Configured to reject policies. To set the Fabric-Wide Consistency Policy to "strict" for SCC and "tolerant" for DCC: switch:admin> fddcfg --fabwideset "SCC:S;DCC" See Also distribute 220 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 253
restrictions that may be in place. Operands none Examples To display the FDMI cache: switch:admin> fdmicacheshow Switch entry for domain 3 state: known version: v310 wwn: 10:00:00:60: of devices on the switch is 1 See Also fdmiShow Fabric OS Command Reference Manual 221 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 254
switch:admin> fdmishow Local HBA database contains: 10:00:00:00:c9:25:9b:96 Ports: 1 10:00:00:00:c9:25:9b:96 Port attributes: FC4 Types: 0x0001000001000000000000000000000000000000000000000000000000000000 Supported 00000001 Driver Version: SLI-2 SW_DATE:May 3 2002, v5-2.11a2 **CT_TEST 1** Firmware - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 255
" entries are not removed from the RNID database. Examples To clear the RLIR database: switch:user> ficonclear RLIR successfully clear local RLIR Database. To clear RNID database: switch:user> ficonclear RNID successfully clear not current entries from local RNID Database. See Also ficonHelp - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 256
switch. All the parameters described below can be set while the switch is Management Server (FMS) mode for the switch. When the operand is fmsmode, the switch: switch:admin> ficoncupset fmsmode enable fmsmode for the switch is now Enabled To set ASM bit in the mode register for the switch: switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 257
display mode register for the switch: switch:user> ficoncupshow modereg POSC UAM ASM DCAM ACP HCP 1 0 1 1 1 0 To display ASM bit in the mode register for the switch: switch:user> ficoncupshow modereg ASM ASM --1 See Also ficoncupset Fabric OS Command Reference Manual 225 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 258
a list of FICON support commands, with descriptions. Operands none Examples To display a list of FICON commands: switch:admin> ficonhelp ficonclear Sets FICON-CUP parameters for a switch ficoncupshow Displays FICON-CUP parameters for a switch ficonhelp N/A ficonshow Displays contents of - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 259
of the channel port is not current. 0x40 Indicates the node ID of the storage port for RNID switch for RLIR is not valid. 0x50 Indicates the node ID of the channel port is not valid. Fmt . FRU Serial Number Displays the FRU serial number. Fabric OS Command Reference Manual 227 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 260
by 1 for each incident within the individual switch. Link Incident Description Same as Link Incident type for the switch in three bytes, 0xAABBCC: Byte AA 0x20 FC-SB-2 and updates. Byte BB Switch. 0x0a Byte support not specified. 0xa0 Reserved. 0xc0 Reserved. 228 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 261
ficonShow 2 0xe0 Vendor specific. Byte BB 0x00 Unspecified is an storage port; otherwise, an emulated control unit support only. 0x09 Reserved. 0x10 Switch, if it is a switch device; otherwise, reserved. 0x0b-0xff Reserved. Byte CC . Fabric OS Command Reference Manual 229 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 262
Displays the switch serial number. Switch node WWN Displays the switch node World Wide Name. Switch Port WWN Displays the switch port World Wide Name. Switch WWN Displays the switch WWN. Tag Manufacturer: IBM Plant of Manufacture: 02 230 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 263
33 Conditional } The LIRR database has 5 entries. To display the local SwitchRNID database: switch:admin> ficonshow switchrnid { {Switch WWN flag Parm 10:00:00:60:69:80:1e:4e 0x00 0x200a00 Type number: 0x50 Node Parameters 0x200105 Fabric OS Command Reference Manual 231 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 264
Failure [3]: Power Supply[4] failure occurred on Mon Jan 13 12:11:38 2003 Fmt Protocol Domain Fabric WWN Switch WWN 0x18 FICON 80 10:00:00:60:69:33:33:33 10:00:00:60:69:80:1e:4e The Local ILIR database has 2 entries. See Also ficonClear 232 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 265
A|B match and AL_PA match Frozen 11 Zone A|B match and AL_PA match Discard Operands This command is supported only on Brocade 3250, 3850, 3900,12000, and 24000 platforms. The execution of this command is this test. The default value is 1. Fabric OS Command Reference Manual 233 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 266
is set if the specified number is larger than the limit. Examples To run a frame filter test: switch:admin> filtertest -txports 3/1-3/3 Running filtertest Test Complete: filtertest Pass 1 of 1 Duration 0 hr, information. See Also itemList 234 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 267
both partitions of the CP to an updated version of the firmware. This must be done after each firmware download and after the switch has been rebooted and a sanity check is performed to make sure the new image is fine. For switches that have nonvolatile memory set into two equal partitions, the - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 268
] Description Use this command to download switch firmware from an FTP server or from a local SSH server to the switch's non-volatile memory. The new firmware is in the form of RPM packages with names defined in pfile, a binary file that contains specific firmware information (time stamp, platform - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 269
firmware, the system must be rebooted. If single CP mode is enabled and this operand is not specified, you must issue the reboot command to activate the downloaded image. If autoreboot mode is enabled, the switch to download the firmware from which slots the firmware will be downloaded to. Valid - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 270
NOTE See the Fabric OS Administrator's Guide "Firmware Download" chapter for limitations when changing of DNS servers with dnsconfig command. To download the firmware to an HA switch: switch:admin> firmwaredownload 192.168.166.30,johndoe switch 238 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 271
format, or is corrupted The FTP or SSH service is not running on host Platform is not supported by the firmware indicated. For other return codes, refer to the Fabric OS Error Message Reference Manual. See Also firmwareCommit, firmwareDownloadStatus, firmwareRestore, firmwareShow, reboot, version - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 272
The following example shows the status of the firmwaredownload for an SAS image to the blades in slot 2 and 7. switch:admin> firmwaredownloadstatus [1]: Thu Jul 28 00:30:49 2005 Slot 2 (SAS): Firmware is being downloaded to the blade. It may take up to 30 minutes. [2]: Thu Jul 28 00:30:49 2005 Slot - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 273
display the status of a firmware download on a Brocade switch: switch:admin> firmwaredownloadstatus [1]: Fri Feb 15 22:17:03 2007 Firmware is being downloaded to the switch. This step may take up to 30 minutes. [2]: Fri Feb 15 22:20:54 2007 Firmware has been downloaded to the secondary partition of - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 274
Mon Dec 19 18:55:39 2005 Slot 5 (CP0, active): Firmware has been downloaded successfully on Standby CP. [12]: Mon Dec 19 18:55:46 19:01:38 2005 Slot 5 (CP0, active): Firmware commit operation has completed successfully on active CP. [16 firmwareshow to verify the firmware versions. See Also firmwareCommit, - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 275
downloaded firmware becomes active. If you then do not want to commit the firmware and want to restore the former firmware place. Operands none Examples To restore the former active firmware image: switch:admin> firmwarerestore Restore old image to be active Reference Manual 243 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 276
SA versions in a Brocade switch or director. It shows the firmware versions on both the primary firmware versions in a Brocade director with FA4-18 blades installed in slot 2 and 7. switch command. To display the firmware version of a Brocade switch: switch:admin> firmwareshow Appl Primary/ - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 277
be of the same technology; that is, a short wavelength SFP (switch) port is connected to another short wavelength SFP (device) port using LEDs rapidly flicker green while the test is running. This command is supported only on Brocade 200E, 3250, 3850, 3900, 4100, 24000, and Manual 245 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 278
omitted, the default value is 512. This operand is optional. Examples To run fportTest on a switch: switch:admin> fporttest -ports 1/0-1/15 Running fPortTest ....... Test Complete: "fporttest" Pass 10 of 10 ERR_STAT_2LONG ERR_STAT_BADEOF 246 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 279
STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. itemList, loopPortTest, portTest, spinFab fportTest 2 Fabric OS Command Reference Manual 247 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 280
of features on a switch. The following features are supported (see Notes for limitations): FC Routing service (see fcrConfigure) iSCSI service (see iscsiCfg) iSNS client service (see isnscCfg) Operands offline and try the command again. 248 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 281
can be run while the switch state is "online". iSNSC The iSNSC service will be disabled on this switch. This command can be run while the switch state is "online". Displays the current operating status of features on the switch. The features shown here may not be supported on all platforms. If you - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 282
to guide the user supported value, specifying the replacement of the WWN card. Examples To replace the World Wide Name card: switch Switch WWN Card Removal and Replacement document. Do you wish to continue [y/n]? y Backing up WWN card data, please wait about 25 seconds for further instruction - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 283
positions correspond to the default areas of the ports. Bit 0 refers to default area of the switch, bit 1 refers to default area 1, and so forth. Bit map of all the trunk slave To display FSPF protocol information: switch:admin> fspfshow Fabric OS Command Reference Manual 251 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 284
= 0x1003e630 agingTID = 0x1004ca28 agingTo = 10000 lsrDlyTID = 0x100507a8 lsrDelayTo = 5000 lsrDelayCount = 1 ddb_sem = 0x1003e6e8 fabP: event_sch = 0x0 See Also bcastShow, topologyShow, uRouteShow 252 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 285
default value is 0 (alarms deactivated). This operand is optional. Examples To enable alarms in Fabric Watch: switch:admin> fwalarmsfilterset FW: Alarms are already disabled switch:admin> fwalarmsfilterset 1 FW: Alarms are aleady enabled See Also fwAlarmsFilterShow Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 286
Domain restrictions that may be in place. Operands none Examples To display the status of alarm filtering in Fabric Watch: switch:user> fwalarmsfiltershow FW: Alarms are enabled switch:user> fwalarmsfiltershow FW: Alarms are disabled See Also fwAlarmsFilterSet 254 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 287
subject to Admin Domain restrictions that may be in place. Operands none Examples To initialize all classes under Fabric Watch: switch:admin> fwclassinit fwClassInit: Fabric Watch is updating... fwClassInit: Fabric Watch has been updated. See Also fwConfigReload, fwConfigure, fwShow Fabric OS - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 288
the Fabric Watch configuration. This command should only be used after downloading a new Fabric Watch configuration file from a host. This command none Examples To reload the saved Fabric Watch configuration: switch:admin> fwconfigreload fwConfigReload: Fabric Watch configuration reloaded See - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 289
modify threshold information for the Fabric Watch configuration. Switch elements monitored by Fabric Watch are divided into classes port. This command requires a Fabric Watch license. Not all platforms support fans or power supplies. If you attempt to configure values for Manual 257 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 290
be in place. In Acess Gateway mode, only the following classes are supported. F/FL Port (Copper) class is supported only on Embedded platforms. .. TABLE 12 Class Access Gateway Mode Area Environmental Performance TX Performance State Changes 258 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 291
Customer Defined Flash Not all platforms support fans or power supplies. If you port. Examples To configure thresholds in Fabric OS mode: switch:admin> fwconfigure 1 : Environment class 2 : SFP class CurVal LastEventTime LastVal LastState Fabric OS Command Reference Manual 259 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 292
Select choice => : (1..5) [5] switch:admin> fwConfigure --disable --port 1 To configure thresholds in Access Gateway mode: switch:admin> fwconfigure 1 : Environment class choice => : (1..5) [5] 5 See Also fwClassInit, fwConfigReload, fwShow 260 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 293
the configuration prompt displays. Examples To change FRU state alert configuration: switch:admin> fwfrucfg The current FRU configuration: Alarm State Alarm Action Slot successfully changed See Also fwConfigure, fwMailCfg Fabric OS Command Reference Manual 261 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 294
Show sensor readings switchStatusPolicySet Set switch status policy parameters switchStatusPolicyShow Show switch status policy parameters switchStatusShow Show overall switch status tempShow Show switch temp readings See Also none 262 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 295
or modify the configuration and status of the Fabric Watch email alert in the switch. Switch elements monitored by Fabric Watch are divided into classes, and email alerts are based Disable Email Alert 3 : Enable Email Alert 4 : Send Test Mail Fabric OS Command Reference Manual 263 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 296
an item => : (0..13) [11] 1 Mail To: [NONE] [email protected] Email Alert configuration succeeded! See Also dnsConfig, fwConfigure, ipAddrSet, ipAddrShow 264 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 297
listed. This command requires a Fabric Watch license. NOTE Port errors are not supported for virtual ports and SFP errors are not applicable for virtual ports The execution --p portNumber Yields a port detail report for a specific user port. Fabric OS Command Reference Manual 265 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 298
switch configured with an IPv6 address: switch:user> fwportdetailshow Port Detail Report Switch Name: switch switch configured with an IPv4 address: switch:user> fwportdetailshow Port Detail Report Switch Name: switch switch:user> fwportdetailshow --s h Port Detail Report Switch Name: switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 299
fwPortDetailShow 2 See Also Port# Type State Dur(H:M) LFA LSY LSI PER INW CRC PSC BLP STM SRX STX SCU SVO 001 F HEALTHY 409:09 014 F HEALTHY 409:09 015 E HEALTHY 409:09 switchStatusShow Fabric OS Command Reference Manual 267 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 300
In an AD-aware environment, this command is allowed only if the local switch is a member of the current Admin Domain. This command requires a Fabric 0 0 0 100 6 U_PORT 0 0 0 100 7 U_PORT 0 0 0 100 See Also portShow, switchShow 268 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 301
period in which a port must be persistently in a state before being actually being recognized as such. Examples To set message levels and port persistence time: switch:user> fwset --port --persistence 18 See Also fwShow Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 302
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To set alarm levels to custom values: switch:admin> fwsettocustom Committing configuration...done. See Also fwSetToDefault 270 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 303
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To return alarm levels to default values: switch:admin> fwsettodefault Committing configuration...done. See Also fwSetToCustom Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 304
class thresholds are supported. F/FL Port (Copper) class threshold is supported only on Embedded platforms . Examples To display thresholds and port persistence time: switch:user> fwshow 1 : Show class thresholds 2 : continued on next page) 272 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 305
envFan001 Env Fan 1 2576 RPM envFan002 Env Fan 2 2518 RPM envFan003 Env Fan 3 2481 RPM switch:user> fwshow 1 : Show class thresholds 2 : Detail threshold information 3 : Show console message level time, last at 16:30:17 on 12/09/2011 Fabric OS Command Reference Manual 273 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 306
Status 1 disabled switch:admin> fwshow --port --persistence FW: current port persistence time = 18s switch:user> fwShow --disable --port Port Threshold Status 1 disabled See Also fwClassInit, fwConfigReload, fwConfigure, fwSet 274 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 307
most recent commands typed into the shell; the oldest commands are replaced as new ones are entered. Operands none Examples To display previous shell commands: switch:admin> h 1 version 2 switchshow 3 portdisable 2 4 portenable 2 5 switchshow See Also none Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 308
Description Use this command to disable the High Availability feature in the switch. If the HA feature is already disabled, this command does nothing none Examples To disable the High Availability feature: switch:admin> hadisable HA is disabled See Also haEnable 276 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 309
High Availability feature in the switch. This command displays the health diagnostic has discovered a problem with the blade. The Channel addresses configured for the switch. Additional internal HA state information about the High Availability feature status: switch:admin> hadump Local CP (Slot 6, - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 310
:9c1/64 cp 1 static fec0:60:69bc:64:205:1eff:fe02:a197/64 FSSME registered: TRUE See Also haFailover, haShow 278 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 311
Description Use this command to enable the High Availability feature in the switch. If the HA feature is already enabled, this command does nothing. To enable the High Availability feature in the switch: switch:admin> haenable HA is enabled See Also haDisable Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 312
Admin Domain-aware environment, this command is allowed only if the local switch is a member of the current Admin Domain. This command is supported only on systems with dual -CP cards. The execution of this See Also haDisable, haEnable, haShow 280 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 313
problem be supported on non switch:admin> hashow Local CP (Slot 6, CP1): Active, Warm Recovered Remote CP (Slot 5, CP0): Standby, Failed Backplane PCI fail, severity: CRITICAL HA enabled, Heartbeat Up, HA State not in sync See Also haDisable, haEnable, haFailover Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 314
synchronization. The execution of this command is subject to Admin Domain restrictions that may be in place. Examples To enable the HA state synchronization: switch:admin> hasyncstart HA State synchronization has started See Also haFailover, haShow, haSyncStop 282 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 315
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To disable the HA state synchronizing process: switch:admin> hasyncstop See Also haFailover, haShow, haSyncStart Fabric OS Command Reference Manual 283 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 316
vary, according to: Login user role License key Switch model To access help information for a specific command, enter the command name as an operand command: switch:admin> help help See Also diagHelp, fwHelp, licenseHelp, perfHelp, routeHelp, zoneHelp 284 Fabric OS Command Reference Manual 53- - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 317
following data sets: Object type FAN, POWER SUPPLY, and one CP switches. Object number Slot number for blades and unit number for everything else. none Examples To display the late FRU insertion or removal event: switch:admin> historylastshow POWER SUPPLY Unit 2 Inserted at Tue Aug 14 15 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 318
operands: rot Rotating mode. fi Log is filled once, then new entries are discarded. Examples To change the history mode to first-in from rotating: switch:admin> historymode History Mode is: Rotating. See Also historyLastShow, historyShow 286 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 319
FRUs, support 28 entries. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the history log of FRUs and removal events: switch:admin> at Tue Aug 14 13:45:07 2001 Fabric OS Command Reference Manual 287 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 320
14 15:52:10 2001 Factory Part Number: 60-0001536-02 Factory Serial Number: 1013456800 Records: 11 See Also historyLastShow 288 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 321
plug-in supported by Web Tools. This command also displays the URL from which the plug-in can be downloaded. The switch:admin> httpcfgshow Current HTTP configuration javaplugin.version = 1,3,1 javaplugin.homeURL = http://java.sun.com/products/plugin See Also Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 322
i [processID] Description Use this command to display information about all of the processes or about a specific process if a process ID is supplied. One line is displayed per process. Fields displayed with this (if blank, process is running) 290 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 323
the following operand: processID Specifies the process name or process ID for the process to display. Examples To display information about process ID 433: switch:admin> i 433 F S UID PID PPID C PRI NI ADDR SZ WCHAN TTY TIME CMD 000 S 0 433 1 0 69 0 - 1283 5c64 ? 00:00:02 fabricd See Also - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 324
supported for all network interfaces or for all Ethernet network interfaces. This command is only functional for the eth0 interface. When selecting auto-negotiation, you can choose the specific different modes. This command is not supported on Brocade 3016 switches. The internal Ethernet in the IBM - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 325
to 10 Mbit/sec half-duplex operation, when entering this command through the serial console port: switch:admin> ifmodeset eth0 Auto-negotiate (yes, y, no, n): [yes] n Force 100 Mbps [no] y Committing configuration...done. See Also ifModeShow Fabric OS Command Reference Manual 293 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 326
eth0, where eth is the network interface and 0 is the physical unit. Examples To display the link operating mode for the "eth0" Ethernet interface: switch:admin> ifmodeshow eth0 Link mode: negotiated 100baseTx-HD, link ok MAC Address: 00:60:69:D0:24:40 See Also ifModeSet 294 Fabric OS Command - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 327
the state is NB_ST_FULL. nghbCap Neighbor capabilities. Should be 0. nghbId Domain ID of the neighbor (adjacent) switch. idbNo IDB number. Should be equal to port_number. remPort Port number on the remote switch connected to this port. Fabric OS Command Reference Manual 295 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 328
to the neighbor switch. attLsaOut Number of attempted transmissions of LSAs to the neighbor switch. nLsaOut Number of LSAs transmitted to the neighbor switch. The execution of this command is subject to Admin Domain restrictions that may be in place. 296 Fabric OS Command Reference Manual 53 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 329
information for all ports on the switch (including non-E_Ports). Examples To display FSPF interface information: switch:user> interfaceshow 1/4 idbP = 0x1008b3d0 = 0x1008c848 inactTo = 80000 helloTo = 20000 (continued on next page) Fabric OS Command Reference Manual 297 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 330
2 interfaceShow rXmitTo nCmdAcc nInvCmd nHloIn nInvHlo nLsuIn nLsaIn attHloOut nHloOut attLsuOut nLsuOut attLsaOut nLsaOut = 5000 = 7 = 0 = 2 = 0 = 2 = 3 = 2 = 2 = 3 = 3 = 2 = 2 See Also nbrStateShow, portShow, switchShow 298 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 331
switches. Configured Domain IDs for Brocade switches must be between 97 and 127 for successful connection to other switches. The firmware World Wide Name zoning is supported in interoperability mode. FC Routing services are not available in interop mode. Switches connected to edge fabrics are not - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 332
service. The switch effective configuration will be lost when the operating mode is changed; do you want to continue? (yes, y, no, n): [no] y Interopmode is enabled Note: It is recommended that you reboot this switch 85 8 5 045500 id N4 No_Light 300 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 333
) [output truncated] 223 8 31 04df00 -- -- Offline Disabled (Persistent) 8 ge0 id 1G Online FCIP 8 ge1 id 1G Online FCIP See Also configure Fabric OS Command Reference Manual 301 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 334
. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To turn off the IOD option: switch:admin> iodreset switch:admin> iodshow IOD is not set See Also iodSet, iodShow 302 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 335
stable fabric, frames are always delivered in order, even when the traffic between switches is shared among multiple paths. However, when topology changes occur in the fabric on the IOD option: switch:admin> iodset switch:admin> iodshow IOD is set See Also iodReset, iodShow Fabric OS - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 336
Use this command to display whether the IOD option is enabled or disabled. Operands none Examples To display the current setting of the IOD option: switch:admin> iodshow IOD is not set See Also iodReset, iodSet 304 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 337
switch, the command ignores all options. The command prompts for the Ethernet IP address, Ethernet subnetmask, Fibre Channel IP address, Fibre Channel subnetmask and gateway IP address. In addition, the command prompts for a specification : Fabric OS Command Reference Manual 305 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 338
Channel subnetmask of logical switch 0. 1 Sets the Subnetmask of logical switch 1. Sets or an IPv6 address on a switch or CP: switch:admin> ipaddrset -ipv6 -cp details for switch number 1 on a chassis-based system: switch:admin> ipaddrset -chassis-based system: switch:admin> ipaddrset Ethernet IP - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 339
To display the IP address for logical switch 0: switch:admin> ipaddrshow -sw 0 Ethernet IP Address: 192.168.166.147 Ethernet Subnetmask: 255.255.255.0 Fibre Channel IP Address: 0.0.0.0 Fibre Channel Subnetmask: 0.0.0.0 See Also ipAddrSet Fabric OS Command Reference Manual 307 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 340
policy created is stored in a temporary buffer and will be lost if the policy is not saved to persistent configuration. 308 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 341
, the address must be in a 128 bit IPv6 address in any format specified by RFC, or a CIDR style IPv6 prefix. -dp Fabric OS Command Reference Manual 309 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 342
service specific policy with an IPv4 address: switch:admin> ipfilter --create ex1 -type ipv4 To add a new rule to the specific policy and specify the source IP address, destination port number, and to permit the rule: switch a specify IP policy and type: Switch:admin> ipfilter --show ex1 Name: - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 343
iscsicfg --clear initiator [-h ] iscsicfg --show initiator [-i initiator_name] [-h ] iscsicfg --abort transaction -x transaction_id [-h ] iscsicfg --show transaction [-h ] iscsicfg --clear all [-h ] iscsicfg --commit all [-f ] [-h ] Fabric OS Command Reference Manual 53-1000436-01 iscsiCfg 2 311 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 344
changes to nonvolatile memory. This triggers the propagation of changes to all iSCSI-enabled switches and blades in the fabric. Changes will not take effect until a --commit all ] Binds user names defined in AUTH database to the specific target 312 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 345
iscsiCfg 2 lun dd ddset Fabric OS Command Reference Manual 53-1000436-01 --delete tgt -t target_name [-h ] Deletes a member_list has to be iSCSI entity names in a valid format. Currently, only IQN format is supported. Multiple entities may be specified as a comma-separated list. The IQN may be a - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 346
To create a CHAP entry: switch:admin> iscsicfg --create auth -u user1 -s abcdefg123 The operation completed successfully. To modify a CHAP entry associated with an existing user: switch:admin> iscsicfg --modify auth -u user1 -s newsecret 314 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 347
-t iqn.2005-10.com.brocade.tgt1 -a CHAP The operation completed successfully. To display the target database: switch:admin> iscsicfg --show tgt Number of records found: 2 Name: State/Status: iqn.2005-10.com. :37:df:8e:e3 Operation Succeeded Fabric OS Command Reference Manual 315 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 348
switch:admin> iscsicfg --add lun -t iqn.2005-10.com.brocade.tgt1 -w 22:00:00:04:cf:20:5d:33 -l 0:0 The operation completed successfully. switch successfully. To display LUN maps: switch:admin> iscsicfg --show lun Number name and members: switch:admin> iscsicfg --create DD database: switch:admin> - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 349
operation completed successfully. To display the DD set database in verbose mode: switch:admin> iscsicfg --show ddset -v Number of records found: 1 Name: aware switches and their operational states switch:admin> iscsicfg --show fabric Switch ID Switch WWN * 1 10:00:00:60:69:e4:20:1e Switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 350
--abort transaction -x 19359 The operation completed successfully. See Also To commit the changes to persistent memory: switch:admin> iscsicfg --commit all The operation completed successfully. fosConfig, iscsiPortCfg, iscsiSessionCfg 318 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 351
the specified slot slotnumber will be used. This number will be between 0 and 7. 8 will mean all ports. Examples To run iscsichiptest: switch:admin> iscsichiptest --slot 7 -unit 1 -testtype 0 Running iscsichiptest Test Complete: iscsichiptest Pass 1 of 1 Duration 0 hr, 3 min & 12 sec (0:3:12:511 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 352
Use this command to display a list of iSCSI support commands, with descriptions. Operands This command has the following iscsi support commands and operands: -fclunquery [-w | -m -s isnsccfg --reregister isnsccfg --show 320 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 353
the list of iSCSI support commands: switch:admin> iscsihelp fclunquery Display a list of LUNs of FC target(s). fosconfig Enable/disable FabOS services iscsicfg Manage/display all iscsi /arp entries on the GigE Port See Also switchShow Fabric OS Command Reference Manual 321 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 354
until the specified number of frames has been transmitted on each port. The default value is 100. Examples To run iscsipathtest: switch:admin> iscsipathtest --slot 2 -path 2 -nframes 10 Running iscsipathtest Test Complete: iscsipathtest Pass 10 of 10 Duration 0 hr, 3 min & 1 sec (0:3:0:630 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 355
Error recovery level 0 Connections per session 1 Data digest support Disabled Header digest suppor Disabled Immediate data support No First burst length value 512 The execution of this level information. slot Specifies the slot number. Fabric OS Command Reference Manual 323 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 356
supports FC4-16IP blades in Brocade 48000 directors. geport -h Specifies the port number of a GbE port to be configured in the specified slot. Use -h on any option to display the help text for it. Examples To modify the port parameters: switch Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 357
.1991-05.com.microsoft:win-iscsi.lab iqn.2002-12.com.tgt:21:00:00:04:cf:5d:cf:0e 0x400001370000 Fabric OS Command Reference Manual 325 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 358
. Normal 0x400001370000 1025 30.50.1.115 1 TCP Connection Details Index TCP Port Leading Connection Switch Port 1 2743 Yes 8/ge4 Security Details CHAP Username: none FC Details Number of FC 64KB Max outstanding R2T 1 16 326 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 359
: 0 Non FCP out PDU: 0 Non FCP out Octet: 0 See Also fosConfig, iscsiCfg, iscsiPortCfg 60s 0s 2 Off Peer 64KB On On On Fabric OS Command Reference Manual 327 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 360
command to display or configure iSCSI switch level confugration. The iSCSI switch level configurations are the iSCSI connection redirection and target name prefix. Operands This command has the following operands: --enableconn Enables the connection redirection on a specific slot or all slots - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 361
See Also fosConfig, iscsiCfg, iscsiPortCfg iscsiswcfg 2 Fabric OS Command Reference Manual 329 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 362
iscsitargetname --show Target name is: iqn.2002-12.com.brocade To change the target name prefix: switch:admin> iscsitargetname --modify -u iqn.2002-10.com.brocade The operation completed successfully See Also fosConfig, iscsiCfg, iscsiPortCfg 330 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 363
VE_Ports, so the speed displays as "sp:-------". Operands none Examples To display the ISL connections for the switch: switch:user> islshow 1: 33-> 29 10:00:00:60:69:80:4f:84 TRUNK 2: 39-> 000G 0.001G 0.125G See Also switchShow, trunkShow Fabric OS Command Reference Manual 331 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 364
an iSCSI blade. NOTE: This parameter supports Brocade FC4-16IP blades in Brocade iSNS server (GbE port attached): switch:admin> isnsccfg --set 7/ge0 -s of the iSNS server (Management port attached) switch:admin> isnsccfg --set -m -s 192.168 of the iSNS client daemon switch:admin> isnsccfg --show iSNS - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 365
isnscCfg 2 See Also Initiated re-register of iSNS objects with iSNS server To clear the IP address of iSNS server: switch:admin> isnsccfg --clear Cleared iSNS server configuration. none Fabric OS Command Reference Manual 333 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 366
described earlier. In the case of multiple item list parameters, the last one on the command line overrides previous settings. 334 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 367
higher-level tests, such as spinSilk to specify which user-accessible external ports within the current switch (selected during telnet login) are tested. When specified in an item list, user ports might , portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 335 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 368
restrictions that may be in place. Examples To terminate an open telnet connection: switch:admin> killtelnet Collecting login information....Done List of telnet sessions (3 found) Session No to terminate (q to quit) q See Also none 336 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 369
switch. Some features of the switch and the fabric to which it is connected are optional, licensed products. Without a license installed for such products, their services switch must be rebooted if a fabric license is added to a switch that lacks a fabric license. In this case, the switch switch switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 370
:admin> licensehelp licenseAdd licenseIdShow licenseRemove licenseShow Add a license to this switch Show system license ID Remove a license from this switch Show current licenses See Also licenseAdd, licenseIdShow, licenseRemove, licenseShow 338 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 371
, the services provided by these features are not available. For dual-domain systems, a single license enables both logical switches to use these products. The chassis is assigned a license ID from which a license is generated. Such licenses are locked and are only functional on the specific system - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 372
to make adjustments to the dynamic assignments to adjust to specific site requirements. These options are used in the case where there licenses can support. Operands This command has the following operands: --release portnumber Releases a license assignment from a port when the switch is using - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 373
licensePort 2 5 ports are assigned to the first POD license Ports assigned to the base switch license: 0, 1, 2, 3, 4, 5, 6, 7, 15, 16 Ports assigned to the first POD license: 8, 9, 17, Also licenseAdd, licenseRemove, licenseShow, licenseHelp Fabric OS Command Reference Manual 341 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 374
to remove an existing license key from a switch. The existing license key must be entered exactly product uninstalled. After removing a license key, the switch must be rebooted. With no license key, licenseShow a license key from the switch: switch:admin> licenseremove "bQebzbRdScRfc0iK" removing - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 375
of licensed products enabled by these keys. The message "No license installed on this switch" is displayed when no licenses are installed. The execution of this command is To display the installed license keys on a switch: switch:admin> licenseshow bQebzbRdScRfc0iK: Web license Zoning license - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 376
a dimensionless positive number. The FSPF protocol compares the cost of various paths between a source switch and a destination switch by adding the costs of all the ISL's along each path. FSPF chooses the path with of all ports is displayed. 344 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 377
:admin> linkcost 2/4 500 switch:admin> linkcost 2/4 Interface2/4 Cost switch:admin> linkcost 2/4 0 switch:admin> linkcost 2/4 500 (STATIC) Interface2/4 Cost 1000 See Also interfaceShow, lsDbShow, topologyShow, uRouteShow, fcrRouterPortCost Fabric OS Command Reference Manual 345 53-1000436 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 378
as new user. Synopsis login Description Use this command to log in to the switch with another user name and password, without first logging out from the original in as admin from the login user: switch:user> login login: admin Password:xxxxxx See Also logout 346 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 379
command is accepted as a synonym for logout, as is Ctrl-D at the beginning of a line. Operands none Examples To log out from an rlogin session: switch:admin> logout See Also login Fabric OS Command Reference Manual 347 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 380
of the same technology, meaning that a short wavelength SFPed (switch) port is connected to another short wavelength SFPed (device) port is recommended for advanced users and technical support only. This command is supported only on Brocade 200E, 3250, 3850, Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 381
word 4 quad This operand is optional. Examples To perform a loopback port test: switch:admin> loopporttest -ports 1/0-1/15 Running Loop Port Test ....... Test Complete: "loopporttest , portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 349 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 382
2 lsanZoneShow lsanZoneShow Displays logical SAN zone information. Synopsis lsanzoneshow [-s] [-f fabricid] [-w wwn] [-z database for zones is displayed per switch which can be different than the database stored on the other FCR switches. 350 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 383
lsanZoneShow 2 Examples See Also To display the LSAN zones: switch:admin> lsanzoneshow Fabric ID: 4 Zone Name: lsan_fcr10_0 50:05:07 0b:83 50:05:07:65:05:84:09:0e switch# fcrFabricShow, fcrPhyDevShow, fcrProxyDevShow, fcrRouteShow, switchShow Fabric OS Command Reference Manual 351 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 384
database entry, which is permanently allocated. The link state record (LSR), which is allocated when a switch is connected to the fabric. The LSR describes the links between connected domains in a fabric. For identical to the domain number. 352 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 385
type lsDbShow Display Fields (Continued) Description ID (domain number) of the switch that originated this LSR. Incarnation number of this LSR. Total length, in : Link State Record pointer = 0x10053d18 lsAge = 16 reserved = 0 type = 1 Fabric OS Command Reference Manual 353 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 386
cost = 500, costCnt = 0, type = 1 14, cost = 500, costCnt = 0, type = 1 15, cost = 500, costCnt = 0, type = 1 The local switch has sixteen links in NB_ST_FULL state, all of them are connected to switch 2. See Also interfaceShow, nbrStateShow 354 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 387
total used Mem: 129740800 112562176 Swap: 0 0 switch:admin> memshow -m total used Mem: 123 107 Swap: 0 0 free 17178624 0 free 16 0 shared 0 buffers cached 139264 30396416 shared 0 buffers 0 cached 28 See Also saveCore Fabric OS Command Reference Manual 355 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 388
used for the four frames, one pattern each: 1000 bytes of CSPAT 480 bytes of RDRAM_PAT 2112 bytes of BYTE_LFSR 356 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 389
of portLoopbackTest and spinSilk can be used to determine which components of the switch are faulty. Operands The following operands are optional: --slot slotnumber Specifies the and SERDES loopback 9 Backend bypass and internal loopback Fabric OS Command Reference Manual 357 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 390
-63 To run a functional test on slot 1 using external (SERDES) loopback: switch:admin> minicycle --slot 1 -lb_mode 2 Running minicycle One moment please ... Path 6 ... Spinning ... Path 7 ... Spinning ... Test Complete: minicycle Pass 1 of 1 358 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 391
4 sec (0:1:4:409). passed. To run a functional test on ports 0, 1, 2, and 8 using port loopback: switch:admin> minicycle -ports 0,1,2,8 -lb_mode 1 Back Plane Loop Back mode is ON. Running mini Cycle One moment please ... RXQ_RAM_PERR Fabric OS Command Reference Manual 359 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 392
the Fabric OS Message Reference for more information. See Also backport, camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest 360 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 393
is 0 and designed to operate on fixed-port-count products. Examples To display all index 1 ASIC pair properties: switch:user> minispropshow 1 -all slot: 1, miniS: 0 [2/16] (be,5) (be,4) fe,13) (fe,12) See Also none Fabric OS Command Reference Manual 361 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 394
the supported MS capabilities for each switch in the fabric: Switch WWN 10:00:00:60:69:20:15:71 10:00:00:60:69:00:30:05 Capability Name 0x0000008f "switch1"* 0x0000008f "switch2" Capability Bit Definitions: Bit 0: Basic Config Service Supported. Bit 1: Platform Management Service Supported. Bit - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 395
to configure the MS ACL. MS allows a SAN management application to retrieve and administer the fabric and interconnect elements, such as switches. This application is located at the Fibre Channel based on its Port/Node WWN select : (0..3) [1] 0 Fabric OS Command Reference Manual 363 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 396
2 msConfigure done ... See Also msCapabilityShow, msPlatShow, msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable, msTdReadConfig, secPolicyShow 364 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 397
may be in place. Operands none Examples To display the MS platform database for a fabric: switch:admin> msplatshow Platform Name: [9] "first obj" Platform Type: 5 : GATEWAY Number of , msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate Fabric OS Command Reference Manual 365 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 398
in place. Operands none Examples To display the MS platform service database control block: switch:admin> msplatshowdbcb Domain Worldwide Name Retry Count Exchange Status msPlatShow, msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate 366 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 399
platform database on all switches in the fabric. Because be issued only from the primary FCS switch. The execution of this command is subject switch:admin> msplcleardb MS Platform Service is currently enabled. This will erase MS Platform Service clearing MS Platform Service Database!! See Also - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 400
disabled. Before issuing, run the msCapabilityShow command to verify all switches in the fabric support MS platform service; otherwise, the command fails. When security is enabled, this command can be issued only from the primary FCS switch. The execution of this command is subject to Admin Domain - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 401
entire fabric. This command deactivates the MS platform service for each switch in the fabric and commits the change to nonvolatile storage. When security is enabled, this command can be issued only from the primary FCS switch. This command is supported only in AD0 and AD255 contexts. The execution - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 402
is used, this command attempts to disable the topology discovery service on all switches in the fabric. When security is enabled, and using the "ALL" operand, this command can be issued only from the primary FCS switch. This command is supported only in AD0 and AD255 contexts. The execution of this - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 403
used, this command attempts to enable the MS topology discovery service on all switches in the fabric. When security is enabled, and using the "ALL" operand, this command can be issued only from the primary FCS switch. This command is supported only in AD0 and AD255 contexts. The execution of this - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 404
restrictions that may be in place. Operands none Examples To display the status of the topology discovery service: switch:admin> mstdreadconfig *MS Topology Discovery is enabled. See Also msCapabilityShow, msConfigure, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable 372 Fabric - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 405
the login session details. The login session gives details of the following: CP/switch (or console/serial port) used to log in The IP address of the Examples To display current login information: switch:admin> myid Current Switch: switch Session Detail: switch (123.123.123.123) Active Redundant - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 406
to the local switch, or information about a specific neighbor if a port Domain Domain number of remote switch. Remote Port E_Port (interface) on remote switch. State State of the neighbor display information about switches directly connected to the local switch: switch:user> nbrstateshow 2/0 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 407
and received on each interswitch link (ISL) or a specific ISL. These counters display using the using the interfaceShow command = 11 = 12 = 12 = 17 = 17 switch:admin> nbrstatsclear 1/0 switch:admin> interfaceshow 1/0 idbP = 0x10050a38 Fabric OS Command Reference Manual 375 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 408
= 500 (output truncated) nCmdAcc = 0 nInvCmd = 0 nHloIn = 0 nInvHlo = 0 nLsuIn = 0 nLsaIn = 0 attHloOut = 0 nHloOut = 0 attLsuOut = 0 nLsuOut = 0 attLsaOut = 0 nLsaOut = 0 See Also interfaceShow, portShow, switchShow 376 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 409
on next page) NL 0314d4; 3;22:00:00:04:cf:9f:26:7e;20:00:00:04:cf:9f:26:7e; 0 Fabric OS Command Reference Manual 377 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 410
WWN "20:00:00:e0:8b:01:ce:d3": switch:user> nodefind 20:00:00:e0:8b:01:ce: display all the device information matching the PID "0x020eef": switch:user> nodefind 0x020eef Remote: Type Pid COS PortName NodeName NL the given no match: switch:user> nodefind abcd No device found. See Also - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 411
Nx_Port, using FLOGI to login to the switch Virtual Contrived device by the switch NPV Device connected to the Nx_Port, using FDISC to log in to the switch iSCSIDevice connected to the iSCSI port The second SCSI initiator and an SCSI target Fabric OS Command Reference Manual 379 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 412
Aliases: The Local Name Server has 6 entries } To display local NS information with aliases with the -r option: switch:admin> nsaliasshow -r { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00:03 : MyAlias1 MyAlias2 380 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 413
Name Server has 6 entries } To display local NS information with aliases with the -r and -t options: switch:admin> nsaliasshow -r -t { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00 Also nsAllShow, nsShow, switchShow Fabric OS Command Reference Manual 381 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 414
addresses of all devices in all switches in the fabric. If the type type operand causes the switch to send out a query to every switch in the fabric. specific FC-PH device type codes: 8 = FCP type device 4 , 5 = FC-IP type device Other FC-PH types are displayed in the format "x ports supporting - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 415
Pid The 24-bit Fibre Channel address COS A list of classes of service supported by the device PortName The device's port World Wide Name (WWN) NodeName display all switch and device entries discovered by the NS in the fabric: switch:admin> nscamshow Fabric OS Command Reference Manual 383 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 416
switches: Switch :00:60:69:00:ab:ba Switch entry for 4 state rev owner known v320 0xfffc01 Device the -t option: switch:admin> nscamshow -t nscam show for remote switches: Switch entry for 2 60:69:00:ab:ba Device type: Physical Initiator Switch entry for 4 state rev owner known v320 0xfffc01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 417
from all switches. Each line of output displays: Type U for unknown, N for N_Port, NL for NL_Port. PID 24-bit Fibre Channel address. COS List of classes of service supported by device. controller for events detected by the fabric. Fabric OS Command Reference Manual 385 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 418
switch Virtual Contrived device by the switch NPV Device connected to the Nx_Port, using FDISC to log in to the switch /target)". To display local NS information: switch:admin> nsshow { Type Pid COS PortName switch:admin> nsshow -r { Type Pid COS PortName NodeName SCR - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 419
Name Server has 2 entries } See Also To display local name server information with "-r" and "-t" options. switch:admin> nsshow -r -t { Type Pid COS PortName NodeName SCR N 010100; 3;21:00:00:e0:8b: entries } nsAllShow, switchShow Fabric OS Command Reference Manual 387 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 420
address COS A list of classes of service supported by the device PortName The device's port switch automatically registers SCSI inquiry data for FCP target devices): FC4 supported the online devices zoned with the given device: switch:admin> nszonemember 0x0416e2 3 local zoned members: Type - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 421
No remote zoned members To display information about all the online devices zoned with the given WWN: switch:admin> nszonemember 10:00:00:00:c8:23:0b:ad 3 local zoned members: Type Pid Pid: 0xb00e00 Aliases: dl360_130251a dl360_130251a Fabric OS Command Reference Manual 389 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 422
Pid: 0xba1ae4 Aliases: trimm100a_2 To display all the unzoned devices in the fabric: switch:admin> nszonemember -u Pid: 0xb01ea9; Aliases: trimm32b_1 Pid: 0xb01eaa; Aliases: trimm32b_2 Pid in the fabric. See Also cfgShow, nscamShow, nsShow 390 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 423
Use this command to change a user account password. The passwd command is allowed on all switches in the fabric unless the fabric is configured for security when Secure Fabric OS is enabled. If a subset of your account's AD member list. Fabric OS Command Reference Manual 391 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 424
of any user level causes the login session of that account (if logged in) to terminate. • Switches will accept the password database that have the SecurityAdmin role listed. For adding, deleting, or changing when prompted for the old password. 392 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 425
.You have entered a password that contains invalid characters. Refer to the Fabric OS Message Reference for more information. login, logout, passwdCfg Fabric OS Command Reference Manual 393 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 426
this command to manage password policies. When secure mode is enabled, passwdCfg is not supported. Use --set to configure the following password policies: Password strength policy Password history is recorded in the user's password history. 394 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 427
to Admin role accounts. A failed login attempt counter is maintained for each user on each switch instance. The counters for all user accounts are reset to zero when the account lockout policy must be less than or equal to -minlength value. Fabric OS Command Reference Manual 395 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 428
login equals the "passwdcfg.lockoutthreshold", the account gets locked for the "passwdcfg.lockoutduration" duration. The particular account is unlocked manually using userconfig --change -u by root/factory/security admin/admin users or it will automatically get unlocked after - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 429
and that passwords expire in 90 days from the date they are defined: switch:admin> passwdcfg --set -uppercase 2 -maxpasswordage 90 Diagnostics If there is command. Command not supported passwdCfg is not supported when secure mode is enabled. Fabric OS Command Reference Manual 397 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 430
must be greater than or equal to 0 and less than or equal to -minlength value. total strength specification out of range The total of -lowercase value, -uppercase value, -digits value, and -punctuation value between 1 and 40 passwd, userConfig 398 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 431
or failure. It might fail if a switch along the path is busy: for instance, if a switch is performing a warm recovery or if a switch along the path does not support this feature. If the advanced performance is currently recognized by FSPF. Fabric OS Command Reference Manual 399 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 432
hop from the source switch to the destination switch. In order to port A on switch X to port B on switch Y might be switches, or the reverse path might even involve different switches to specify a sequence of switches, ports, or areas expressed as a sequence of switches, a sequence of output ports - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 433
switches along switches are reported in the path description. If two switches switches in between will be ignored. In case of a loose source route, the switches Switches running pre 5.2 firmware cannot use ports > 256 as a destination port on a remote switch switch switches next switch, switches - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 434
display basic path information to a specific domain, using the command line (noninteractive mode): switch:admin> pathinfo 91 Target port is 2119951 2121767 Frames 20025929 54999 162338 56710 Errors - 4 - 0 (continued on next page) 402 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 435
pathInfo 2 Hop In Port Domain ID (Name) Out Port BW Cost 2 14 8 (web228) E - - (output truncated) See Also portStatsShow, switchShow Fabric OS Command Reference Manual 403 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 436
the latest panic dump file available on the switch. If a panic dump file is specified as an argument, the contents of that specific file are displayed. Operands This command has the Output (output truncated) See Also portLogDump, saveCore 404 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 437
monitors. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports 0. SourceID and DestID both cannot be 0x000000. Fabric OS Command Reference Manual 405 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 438
To add an end-to-end monitor to blade 1 port 2: switch:admin> perfaddeemonitor 1/2 "0x050200" "0x1182ef" End-to-End monitor number , perfAddUserMonitor, perfAddWriteMonitor, perfClearEEMonitor, perfDelEEMonitor, perfShowEEMonitor 406 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 439
This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE monitor. Examples To add an IP monitor to a port: switch:admin> perfaddipmonitor 1/4 "IP_MONITOR" IP traffic frame monitor #0 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 440
monitor. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports To add an SCSI read monitor to a port: switch:admin> perfaddreadmonitor 2/4 "SCSI_R" SCSI Read filter monitor - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 441
monitor. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE an SCSI read and write monitor to a port: switch:admin> perfaddrwmonitor 2/4 "SCSI_RW" SCSI Read/Write filter monitor - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 442
monitor. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE add a SCSI traffic frame monitor to a port: switch:admin> perfaddscsimonitor 2/4 "SCSI_FR" SCSI traffic frame monitor - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 443
command. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE 0x0; valueList values are specified with: 0 SOFf 1 SOFc1 Fabric OS Command Reference Manual 411 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 444
. Examples To add a filter-based monitor for all Extended Link Service requests (R_CTL=0x22 and TYPE=0x01) to a port: switch:admin> perfaddusermonitor 1/4 "4, 0xff, 0x22; 12, 0xff, 0x01 add a filter-based monitor for SOFi3 to a port: switch:admin> perfaddusermonitor 1/4 "0, 0xff, 6" User monitor #1 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 445
This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and To add an SCSI Write command monitor to a port: switch:admin> perfaddwritemonitor 2/4 "SCSI_W" SCSI Write filter monitor #0 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 446
Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, clear the performance monitoring information from nonvolatile memory: switch:admin> perfcfgclear This will clear Performance Monitoring Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 447
Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M monitoring configuration information from nonvolatile memory: switch:admin> perfcfgrestore This will overwrite current Performance Command Reference Manual 415 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 448
a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M To save the current performance monitoring configuration to firmware: switch:admin> perfcfgsave This will overwrite previously saved Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 449
[ALPA] Description Use this command to clear a specific CRC error counter associated with a specific port and AL_PA, or all such counters on a port. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 450
with a specific monitorId. Issuing This command is not supported on virtual FC ports switch:admin> perfcleareemonitor 1/2 This will clear ALL EE monitors' counters on port 2, continue? (yes, y, no, n): [no] y See Also perfAddEEMonitor, perfShowEEMonitor 418 Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 451
with a specific monitorId. command is not supported on virtual FC switch:admin> perfclearfiltermonitor 1/2 This will clear ALL filter-based monitors' counters on port 2, continue? (yes, y , no, n): [no] y See Also perfAddFilterMonitor, perfShowFilterMonitor Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 452
a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror on a port, or all such monitors: switch:admin> perfdeleemonitor 7/2 5 End-to-End monitor number 5 deleted switch:admin> perfdeleemonitor 7/2 This will remove ALL EE - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 453
Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), switch:admin> perfdelfiltermonitor 2/3 This will remove ALL monitors on port 19, continue? (yes, y, no, n): [no] y See Also perfAddUserMonitor, perfShowFilterMonitor Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 454
Examples To display commands related to performance monitoring: switch:admin> perfhelp perfAddEEMonitor perfAddIPMonitor perfAddReadMonitor perfAddRWMonitor perfAddSCSIMonitor perfAddUserMonitor the current end-to-end mask See Also none 422 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 455
license. This command is not supported on virtual FC ports (VE/ switch:admin> perfmonitorclear --class FLT 1/2 This will clear ALL filter-based monitors' counters on port 2, continue? (yes, y, no, y): [no] y To clear statistics counters for an ISL monitor: Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 456
2 perfMonitorClear switch:admin> perfmonitorclear --class ISL 1 This will clear ISL monitor on port 1, continue? ( , perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor, perfMonitorShow 424 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 457
. Monitor classes include end-to-end monitors (EE), filter-based monitors (FLT), and Inter-Switch Link monitors (ISL). ISL monitors are automatically activated on E_Ports (not including trunk slaves). End for a standalone ISL, more for trunks) Fabric OS Command Reference Manual 425 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 458
Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port IPV6 addresses: switch:admin> perfmonitorshow EE monitors configured on the switch port number using an application at an interval of every 6 seconds: switch:admin> perfmonitorshow --class EE 4/5 6 perfmonitorshow - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 459
To display cumulative filter monitor information on a port: switch:admin> perfmonitorshow --class FLT 2/5 There are 7 on a port at an interval of every 6 seconds: switch:admin> perfmonitorshow --class FLT 2/5 6 perfmonitorshow 21, 6 port: switch:admin> perfmonitorshow --class EE 4/5 There are 7 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 460
97: 110379 Domain 98: 13965 Domain 99: 1337982 To display EE moniors configured on port number 0: switch:admin> perfmonitorshow --class EE 0 There is 1 end-to-end monitor defined on port 0. KEY SID perfAddUserMonitor, perfAddWriteMonitor 428 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 461
the following values to turn on or off a specific field: 00 Specifies that the field does not address field must be masked together, to support the FC4-48 blade. On this blade AL_PA ID address fields are masked separately, the switch will not be able to track frames sent Manual 429 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 462
RxDIDMsk Specify the following values to turn on or off a specific field: Specifies that the field does not trigger EE monitors. Examples To set the overall mask for end-to-end monitors on a port: switch:admin> perfsetporteemask 1/6 "00:00:00" "ff:ff:ff" "00:ff:ff Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 463
Monitoring license. This command is not supported on the Brocade 200E, 4100, and 48000 platforms. This command is not supported on virtual FC ports (VE/ error count for all AL_PA devices on a port: switch:admin> perfshowalpacrc 2/4 ALPA CRC_ERROR_COUNT 0x01 0 0x03 0 See Also - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 464
Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EE monitors configured on the switch port 0: switch:admin> perfshoweemonitor 0 There is configured on the switch port 0 using an application that passes an IPV6 address: switch:admin> perfshoweemonitor - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 465
a port at an interval of every 6 seconds: switch:admin> perfshoweemonitor 4/5 6 perfshoweemonitor 53, 6: Tx/ 52m 0 To display cumulative information from EE monitors on a port: switch:admin> perfshoweemonitor 4/5 There are 7 end-to-end monitor(s) defined platforms do not support counting CRC - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 466
is deprecated; use perfMonitorShow instead. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M ( filter monitor traffic on a port at an interval of every 6 seconds: switch:admin> perfshowfiltermonitor 2/5 6 perfshowfiltermonitor 21, 6 0 1 2 3 4 5 Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 467
2 To display filter monitor information on a port: switch:admin> perfshowfiltermonitor 2/5 There are 7 filter-based monitors defined perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor Fabric OS Command Reference Manual 435 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 468
command is deprecated; use perfMonitorShow instead. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) of valid ports. Examples To display the end-to-end mask on a port: switch:admin> perfshowporteemask 2/4 The EE mask onport 20 is set by application NONE TxSID - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 469
perfShowPortEEMask 2 RxSID ALPA: on RxDID Domain: on RxDID Area: on RxDID ALPA: on See Also perfAddEEMonitor, perfDelEEMonitor, perfSetPortEEMask, perfShowEEMonitor Fabric OS Command Reference Manual 437 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 470
generated... Installing Root Certificate... If run in secure mode, the following error message is displayed: switch:admin> pkicreate Warning !! Switch is in secure mode. Cannot create new Pki Objects. Exiting... See Also pkiRemove, pkiShow 438 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 471
switch private key, private key pass-phrase, CSR, root certificate, and switch switch:admin> pkiremove WARNING!!! Removing switch. If you want secure mode enabled, you will need to get the switch error message is displayed: switch:admin> pkiremove This Switch is in secure mode. Removing - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 472
of PKI objects, such as switch private key, private key pass-phrase, CSR, root certificate, and switch certificate. The execution of this command that may be in place. Operands none Examples To view PKI objects: switch:admin> pkishow Passphrase : Exist Private Key : Exist CSR : Exist - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 473
: 1 Fastest as it uses 768 bit values, but least secure. 14 Slowest as it uses 2048 bit values, but most secure. Fabric OS Command Reference Manual 441 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 474
Examples To create a new policy: switch:admin> policy --create ike 10 -enc 28800 To display a policy setting: switch:admin> policy --show ipsec 1 To display all IKE policy settings: switch:admin> policy --show ike all To display all IPSec policy settings: switch:admin> policy --show ipsec all IPSec - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 475
change (delete and re-create) a policy: switch:admin> policy ike --delete 10 This policy has been successfully deleted. switch:admin> policy ike --create 10 -enc aes Group: 1 SA Life (seconds): 28800 To delete a policy: switch:admin> policy ike --delete 10 The policy has been successfully deleted. - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 476
the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To display the AL_PAs of a port: switch:user> portalpashow 4/14 AL_PA type AL_PA 0xe2 public 0xe4 type public AL_PA type See Also switchShow 444 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 477
groups in the switch. Synopsis portbuffershow all of the port groups of the switch is displayed. The following long distance information and then echoed back to the switch. The supported distance measurement is up to 500 If the connecting port does not support LD mode, is shows "N/A". Remaining - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 478
assist in readability. Examples To display the long distance information a port: switch:user> portbuffershow 17 User Port Lx Max/Resv Buffer Needed Link Remaining Port 18 - - 0 - - 19 - - 0 - - 54 See Also portCfgLongDistance 446 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 479
if omitted, information for all ports is displayed. Ports that support shared areas are divided into two ports: primary and secondary ports 7/31 is primary. In this case portcamshow entries will look like below: switch:user> portcamshow 7/39 Area SID used DID used SID entries DID entries 207 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 480
switch to port 7/39. To display the filter CAM utilization for all ports on a switch: switch:user> portcamshow Ports of Slot 9 Port SID used DID used SID free DID the filter CAM utilization for a single port on a switch: switch:user> portcamshow 3/2 Area SID used DID used SID entries - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 481
: create tunnel_id remote_ipaddr local_ipaddr comm_rate Creates FCIP tunnels. Option specific [optional_args] for create: -c compression Enable compression on the default is 10. If tape pipelining is enabled, minimum value supported is 80. Fabric OS Command Reference Manual 449 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 482
same port. Jumbo frames will not be supported on secure tunnels. Only a single route is supported on an interface with a secure tunnel. it, you must delete it ,and then recreate it. Option specific [optional_args] for modify include: -b comm_rate Specifies the new desired Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 483
slot for bladed systems. For GbE ports, the ports are numbered ge0 and ge1. Use switchShow for a list of valid ports. Fabric OS Command Reference Manual 451 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 484
can also be used to list all the ports configured for FC fastwrite. Usage: portCfg faswrite [slot/][ge]port mode 452 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 485
Succeeded To create an IP interface: switch:admin> portcfg ipif 4/ge0 create 192.168.100.50 255.255.255.0 1500 Operation Succeeded To create a static IP route: switch:admin> portcfg iproute ge0 create 172. Mirror Port .. .. .. .. ON Fabric OS Command Reference Manual 453 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 486
..:OFF, ??:INVALID. LM:L0.5 To configure a range of ports as RSCN supressed: switch:admin> portcfg rscnsupr 2/4-7 --enable switch:admin> portcfgshow [output from other slots suppressed] Ports of Slot 2 0 1 2 3 configure, portShow, switchShow 454 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 487
To reset a GbE port to factory defaults: switch:admin> portcfgdefault 8/ge1 See Also portCfgEPort, portCfgGPort, portCfgLongDistance, portCfgLPort, portCfgPersistentDisable, portCfgPersistentEnable, portCfgShow, portCfgSpeed, portCfgTrunkPort Fabric OS Command Reference Manual 455 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 488
is segmented. No data traffic between two switches is routed through this port. Fabric management are connected between two switches, the maximum routing paths command are persistent across switch reboots or power cycles. switch:admin> portcfgeport 1/3, 0 To enable a port to become an E_Port: switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 489
that is used by the EX_Port's front phantom domain to request a domain ID from the principal switch. The domain ID received becomes the subsequent preferred domain ID which is persistent and displayed. The fabric value is not "Auto Negotiate". Fabric OS Command Reference Manual 457 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 490
used when the neighboring McDATA switch is running OS version such of port 2/0: switch:admin> portcfgexport 2/0 06:9e:20:9f:ce:10 Principal Switch: 7 principal WWN: 10:00:00: switch:admin> portcfgexport 2/1 -f 5 -p 1 To configure port 2/0 to be an EX_Port and set the fabric ID to 4: switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 491
portCfgEXPort 2 See Also switch:admin> portcfgexport 2/0 -t 2 portCfgVEXPort, portDisable, portEnable, portShow, portCfgDefault, fcrbcastconfig Fabric OS Command Reference Manual 459 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 492
as a G_Port. After this is done, the switch attempts to initialize that port as an F_Port only, . Changes made by this command are persistent across switch reboots or power cycles. The execution of this command port as a locked G_Port: switch:admin> portcfggport 1/3, 1 See Also configure, portCfgLPort - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 493
must ensure all fabric-wide parameters are consistent for every switch in the fabric. The complete list of fabric operating mode : NOTE The long distance modes L0, L1, and L2 are no longer supported in v5.3.0. • Trunk port • Long distance • VC link init If Command Reference Manual 461 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 494
. Specify 0 to disable ISL R_RDY mode. To enable ISL R_RDY mode on a port: switch:admin> portcfgislmode 1/3, 1 ISL R_RDY Mode is enabled for port 3. Please make sure the To disable ISL R_RDY mode on a port: switch:admin> portcfgislmode 1/3, 0 See Also configure, portCfgLongDistance, portCfgShow 462 Fabric - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 495
for data traffic, regardless of the port's operating speed; therefore, the maximum supported link distance is 10 Km, 5 Km, or 2.5 Km for the port 2 Gbit/sec, or 4 Gbit/sec, respectively. (On some older switch platforms, the LD mode link can operate up to distances of 200 Km Manual 463 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 496
This feature is not backward compatible with firmware versions that do not support it. If a port is configured credits available. Brocade 200E,4100, and 4900 switches and Brocade 48000 directors using FC4-16 and FC4 for port number vary, depending on the switch type. Use switchShow to display a list - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 497
switch port 63 to support a 100 Km link and be initialized using long-distance link initialization protocol: switch:admin> portcfglongdistance 4/15 LS 1 100 switch configure, portCfgISLMode, portCfgTrunkPort, portCfgShow, portShow, switchShow Fabric OS Command Reference Manual 465 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 498
default value of 0 is used. Private devices are supported only on Brocade 3250, 3850, and 3900 and directors with FC2-16 and FC2-16 blades. For other switches and blade types, option 1 is blocked. duplex_mode Mode Persistent Disable 466 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 499
portCfgLPort 2 where AN:AutoNegotiate, ..:OFF, ??:INVALID. To display the L_Port conditions: switch:admin> portcfglport [output from other slots suppressed] Ports of Slot 4 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Locked L_Port ON Private L_Port Locked Loop HD Loop - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 500
it is connected to the enterprise fabric switch that supports NPIV. The N_Port must have NPIV capability enabled. NOTE NPIV capability should be enabled on the ports connected to the Access Gateway. Use portcfgnpivport to enable NPIV capability on the specific port. By default, NPIV is enabled on - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 501
all Bloom ASIC-based ports. It can be selectively enabled or disabled on switch ports using this command. NPIV HAFor a redundant control processor (CP) system to enable NPIV functionality, it must be running NPIV-enabled firmware versions on both the active and standby CPs. This requirement does not - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 502
ON ON ON ON ON ON ON ON ON ON where AN:AutoNegotiate, ..:OFF, ??:INVALID. LM:L0.5 See Also To disable NPIV functionality on a port: switch:admin> portcfgnpivport 1/3 0 configure, portCfgDefault, portCfgShow 470 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 503
9/3 switch:admin> portcfgpersistentdisable Slot 9 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Disabled - - - YES (output truncated) See Also ficoncupset, ficoncupshow, portCfgDefault, portDisable, portEnable, portCfgPersistentEnable, portShow, switchShow Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 504
the persistent enable attribute of a port. This command is not allowed if the switch is operating in the FICON Management Server mode (fmsmode). Instead use BportEnable with portEnable, portCfgPersistentDisable, portCfgShow, portShow, switchShow 472 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 505
displays port configuration settings for all ports on a switch, except gigabit Ethernet (GbE) ports. Additionally, use this command to display specific FCIP parameters configured for a gigabit Ethernet port, is set by the portCfgEPort command. Fabric OS Command Reference Manual 473 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 506
the GigE and show the current DiffServ markings being used for data connection as well as control connection: switch:admin> portcfgshow fciptunnel ge0 all Port: ge0 Tunnel ID 7 Remote IP Addr 192.168.255.17 Local Kbps (0.001000 Gbps) SACK on 474 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 507
8 DSCP (Control): 10, DSCP (Data): 50 To display the configuration settings for a port with agmode enabled: switch:admin> portcfgshow Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 , portCfgNPIVPort, portCfgSpeed, portCfgTrunkPort Fabric OS Command Reference Manual 475 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 508
. The configuration is saved in nonvolatile memory and is persistent across switch reboots or power cycles. This configuration cannot be set on VE/VEX_Ports of a port to 2 Gbit/sec: switch:admin> portcfgspeed 2/3, 2 See Also portCfgShow, portShow, switchCfgSpeed 476 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 509
Specify 1 to enable this port for trunking. Specify 0 to disable the port from being trunked. This operand is required. Examples To enable a port for trunking: switch:admin> portcfgtrunkport 1/3, 1 See Also portCfgShow, portShow, switchCfgTrunk, switchShow Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 510
that is used by the VEX_Port's front phantom domain to request a domain ID from the principal switch. The domain ID received becomes the subsequent preferred domain ID and is persistent and displayed. The VEX_Port configuration of port 2/16: 478 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 511
WWN: 50:06:06:9e:20:9f:ce:10 Principal Switch: 7 principal WWN: 10:00:00:60:69:c0:05 the port ID format to core: switch:admin> portcfgvexport 2/21 -f 5 -p 1 To configure port 2/ switch:admin> portcfgvexport 2/20 -a 1 -f 4 To disable fabric parameter negotiation on port 2/20 of an VEX_Port: switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 512
or trace route to a destination IP host from an intelligent GbE port. Currently we do not support end-to-end path characterization if there exists an IPSec-enabled tunnel using the same source/local IP end-point. This operand is optional. 480 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 513
. This value is measured in bytes and includes the IP header and payload. Note: There is limited support for black hole PMTU detection. If the Jumbo PMTU (anything over 1500) does not work, --ipperf will address that originates the ping request. Fabric OS Command Reference Manual 481 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 514
that are less than the first_ttl hops. This operand is optional. -q service_type Specifies the type of service in the traceroute request. The default is 0 and service_type must be an integer from 0 to the interface. This operand is optional. 482 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 515
displays indicating that ping is deprecated. To set the path characteristic to source mode on the remote host: switch:admin> portcmd --ipperf 4/ge0 -s 192.168.100.50 -d 192.168.100.0 -S ipperf to 192. is deprecated. See Also portCfg, portShow, Fabric OS Command Reference Manual 483 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 516
Specify the verbose level to be set for port modules; valid values are 1 to 5. Examples To set debug level and verbose level of port modules: switch:admin> portdebug 3 4 See Also dbgShow 484 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 517
command to disable a port. If the port is connected to another switch, the fabric might reconfigure. Devices connected to this port can no list of valid ports. Examples To disable a port: switch:admin> portdisable 2/4 See Also portCfgPersistentDisable, portCfgPersistentEnable, portEnable, - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 518
If the port is connected to another switch, the fabric might reconfigure. Devices connected pop-up window. This command is rejected if the port's switch is disabled, the port's blade is not fully enabled (faulted Examples To enable a port: switch:admin> portenable 2/4 See Also - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 519
error counters for ports on a switch: switch:admin> porterrshow frames enc crc too 0 0 13: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 14: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 15: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 16: 0 0 - 0 0 0 0 - 0 - - - - 17: 0 0 - 0 0 0 0 - 0 - - - - - Fabric OS Command Reference Manual 487 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 520
25: 0 0 - 0 0 0 0 - 0 - - - - 26: 0 0 - 0 0 0 0 - 0 - - - - 27: 0 0 - 0 0 0 0 - 0 - - - - 28: 0 0 - 0 0 0 0 - 0 - - - - 29: 0 0 - 0 0 0 0 - 0 - - - - 30: 0 0 - 0 0 0 0 - 0 - - - - 31: 0 0 - 0 0 0 0 - 0 - - - - - See Also portShow, portStatsShow 488 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 521
place. Operands none Examples To display the port status for all ports in the switch: switch:user> portflagsshow Slot Port SNMP Physical Flags 1 0 Online In_Sync PRESENT ACTIVE E_PORT LED ACCEPT See Also portShow, switchShow Fabric OS Command Reference Manual 489 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 522
port LEDs in the current switch on and off by You must disable the current switch (using the switchDisable command) You can enable the current switch (using the switchEnable command) to switch are assumed. For more information, refer to the itemList command. Examples To test port LEDs: switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 523
information. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To clear the port log: switch:admin> portlogclear switch:admin> portlogshow port log is empty See Also portLogDump, portLogShow Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 524
execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the current port log configuration: switch:admin> portlogconfigshow max portlog entries = 8192 See Also portLogResize 492 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 525
. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands None. Examples To display the port log facility: switch:admin> portlogdisable See Also portLogEnable Fabric OS Command Reference Manual 493 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 526
by this command, refer to the Fabric OS Administrator's Guide. The execution of this command is subject to Admin Domain operand is optional. Examples To display the port log for a port: switch:user> portlogdump 20 time task event port cmd args 08:35:27.899 Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 527
the switch firmware, switch, switch-to-switch, some device-to-device1, and control information If the port log is disabled, the following message displays as the first line. Refer to portLogClear command for more information. WARNING: port log is disabled Refer to the Fabric OS Administrator's Guide - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 528
. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands None. Examples To enable the port log facility. switch:admin> portlogenable See Also portLogDisable 496 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 529
restrictions that may be in place. Operands none Examples Display information about port log events: switch:admin> portlogeventshow ID Event-Name Disabled 1 start 0 2 disable 0 3 enable 0 xalloc 0 (continued on next page) Fabric OS Command Reference Manual 497 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 530
40 xfree 0 41 xerr 0 42 xstate 0 43 seq 0 44 seqst 0 45 iu 0 46 payload 0 47 zone 0 48 cmd 0 49 event 0 50 msg 0 51 switch 0 52 ficonq 0 53 routing 0 See Also portLogTypeDisable, portLogTypeEnable 498 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 531
Service Parameters or Virtual N_Port login. fe FLOGI, Fabric Login to Fabric F_Port. ff PLOGI, Port Login to specific Services supported. This can be a combination of the following bits: 4 Class 2 is supported. 8 Class 3 is supported two PLOGIs): switch:admin> Manual 499 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 532
be in place. Operands This command has the following operand: lvl Specify either 0 to clear or 1 to set the debug_pdisc_flag. Examples To set the pdisc_flag: switch:admin> portlogpdisc 1 PDISC log setting = 1 See Also none 500 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 533
facility. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To enable the port log: switch:admin> portlogreset See Also none Fabric OS Command Reference Manual 501 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 534
to which portlog needs to be resized. The valid range of values is 32,768 to 65,536 for Brocade 48000 Director and Brocade 7500 Switch, and 8,192 to 16,384 for all others. Examples To resize the portlog - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 535
you to press Enter after each page of output. Port logs are circular log files in the switch firmware, which can save up to 32,768 entries. Refer to portLogConfigShow to display the current port debug message nbrfsm Neighbor state transition Fabric OS Command Reference Manual 503 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 536
Displays additional information about the event as follows: Start type: 0 = enable ports, 100 = disable ports State (refer to state codes next) Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 537
(0001 means argument 1 is valid, 0003 means arguments 1 and 2 are valid). [B] the CT-based service command code. Argument 1 is the first word of the CT payload, if applicable (as specified in [A]). in various fields are as follows: state Fabric OS Command Reference Manual 505 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 538
-initialization Speed Negotiation States INIT Start negotiation NM Negotiate master WS Wait for signal NF Negotiation follow NC Negotiation complete 506 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 539
by this command, refer to the Fabric OS Administrator's Guide. The execution of this command is subject to Admin operand is optional. . Examples To view the port log for a port: switch:user> portlogshow 24 time task event port cmd args 17:05:30.384 Reference Manual 507 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 540
Specify the port number of the port to display. Examples To display a port log for port 14: switch:user> portlogshowport 14 time task event port cmd args 08:35:28.483 tFabric scn 14 0 08 See Also portLogClear, portLogShow, upTime 508 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 541
corresponding to different log types can be obtained by running portLogEventShow. Examples To disable event 2 from reporting to the port log: switch:admin> portlogtypedisable 2 See Also portLogDisable, portLogEventShow, portLogTypeEnable Fabric OS Command Reference Manual 509 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 542
be enabled. The values corresponding to different log types can be obtained by running portLogEventShow. Examples To enable event 2 to report to the port log: switch:admin> portlogtypeenable 2 See Also portLogEventShow, portLogTypeDisable 510 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 543
Description Use this command to verify the functional operation of the switch by sending frames from the port N transmitter and looping them an external loopback cable) can be used to determine which components of the switch are faulty. The execution of this command is subject to Admin Domain - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 544
, all of the blade ports in the specified slot (--slot) are used. See itemList for more information. Examples To run a functional test of a connection: switch:admin> portloopbacktest -ports 1/10-1/20 -nframes 1 -lb_mode 1 Running Port Loopback Test .... passed. 512 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 545
STATS TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 513 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 546
switch). A port mirroring connection on FL_Ports mirrors all traffic originating or terminating from this FL_Port. Port mirroring does not support connection. To display all configured mirror ports on a switch use the portCfgShow command. 514 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 547
feature is only supported on the following platforms switch ports: switch:admin> portmirror --delete 0x011400 0x012400 To delete a port mirror connection between a local switch port and a remote switch port: switch:admin> portmirror --delete 0x011400 0x240400 Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 548
To display port mirror connections: switch:admin> portmirror --show Number of mirror connection(s) configured: 2 Mirror_Port SID DID State 10/12 0x791800 0x791900 Defined 10/15 0x791a00 0x799300 Enabled See Also portCfgShow 516 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 549
portName 2 portName Assigns a name to the specificed port, or displays a port name. Synopsis portname [slotnumber are displayed. Examples To name to a port Tape drive 8: switch:admin> portname 1/3, "Tape drive 8" switch:admin> portname 1/3 Tape drive 8 See Also configDefault, portCfgDefault, - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 550
output on VE link may not match the output on the device port. Examples To display port throughput for a switch: switch:user> portperfshow 20 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Total 0 43m 0 87m 0 272k 0 330 0 310m See Also portStatsShow 518 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 551
until all ASIC SRAMs and registers are tested. The command is supported only on Brocade 200E, 3250, 3850, 3900, 4100, 24000 Examples To run a bit write/read test of the ASIC SRAMs and registers: switch:admin> portregtest -ports 1/0-1/15 Running Port Register Test .... Test Complete: "portregtest" - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 552
See Also Refer to the Fabric OS Message Reference for more information. camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, spinSilk, sramRetentionTest 520 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 553
arrangements of ports on an ASIC pair is specific to the system type. For any active port attached to the local switch. The format of port, for handling by the firmware. The execution of this command display the routing tables for a port: switch:user> portrouteshow 4/15 port address ID: - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 554
2 portRouteShow broadcast routing table: 0x10000 See Also bcastShow, fabricShow, switchShow, topologyShow, uRouteShow 522 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 555
iscsi| mode ] [slot] ge port Description Use this command to display general or switch and port specific status information for the specified port. The portshow command with operands other than Islot or portPhys Physical port states include: Fabric OS Command Reference Manual 523 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 556
active) domain ID for the front domain and the WWN of the front domain. Pr Switch Info Information on the principal switch of the edge fabric attached to this EX_Port. This information includes the domain ID and connected to the EX_Port. 524 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 557
"DH_CHAP". DH-CHAP is the only supported authentication type. DH Group If the EX_Port is connected to an edge switch with no security, then the value is "N/A". If the edge switch is in secure mode, then the , and the last LIP received. Fabric OS Command Reference Manual 525 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 558
for a list of valid ports. Examples To display the state of a port: switch:admin> portshow 3 portName: portHealth: HEALTHY Authentication: None portDisableReason: None portCFlags: 0x1 (s) connected: Distance: normal portSpeed: N2Gbps 526 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 559
: State: OK Cur Dom ID: 160 WWN: 50:00:51:e3:60:ee:0e:14 Pr Switch Info: Dom ID: 5 WWN: 10:00:00:05:1e:34:02:04 Fabric params: R_A_TOV: Link_failure: 0 Loss_of_sync: 2 Loss_of_sig: 4 Protocol_err: 0 Invalid_word: 0 Frjt: 0 Fbsy: 0 Fabric OS Command Reference Manual 527 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 560
: No To display IP interfaces on a GbE port: switch:admin> portshow ipif ge0 GE Port 0/ge0 Interface IP for data connection as well as control connection: switch:admin> portshow fciptunnel ge0 all Port: ge0 an FCIP tunnel on a GbE port: switch: admin> portcfgshow ge0 Persistent Disable: - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 561
10, DSCP (Data): 50 To display IP routes on a GbE port: switch:admin> portshow iproute ge0 GE Port 0/ge0 IP Address Mask Gateway Metric Flags 192.168.255.25 1 See Also To display iSCSI Port WWN and Sessions: switch:admin> portshow isci 2/ge0 GE Port 2/ge0 Port WWN Sessions 50:06:06 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 562
/sec). stat64_rateTxByte Tx Byte rate (bytes/sec). stat64_rateRxByte Rx Byte rate (Bytes/sec). stat64_rateTxPeakByte Tx peak Byte rate (Bytes/sec). 530 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 563
list of valid ports. Examples To display the 64-bit hardware statistics for a port: switch:user> portstats64show 4/15 stat64_wtx 0 top_int : 4-byte words transmitted 316 bottom_int : 4-byte with bad end-of-frame (continued on next page) Fabric OS Command Reference Manual 531 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 564
: 4-byte words transmitted 0 bottom_int : 4-byte words transmitted stat64_rxClass1Frames 0 top_int : 4-byte words transmitted 0 bottom_int : 4-byte words transmitted See Also portStatsClear, portStatsShow 532 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 565
End-to-End monitor, and Filter-based performance monitor statistics. Inter-Switch Link (ISL) monitor statistics are not cleared by this command. For for a port: switch:admin> portstatsclear 4/15 See Also portStats64Show, portStatsShow Fabric OS Command Reference Manual 533 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 566
Use this command to display port hardware statistics counters. Some counters are platform and port specific and display only with those platforms and ports. All statistics have a maximum 32-bit value restrictions that may be in place. 534 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 567
Examples To display the basic set of statistics for a port: switch:admin> portstatsshow 13 stat_wtx 0 stat_wrx 0 stat_ftx 0 stat_frx 0 stat_c2_frx for slot 8 and GbE port 1: switch:admin> portstatsshow ge 8/ge1 ge_stat_tx_frms 0 GE transmitted frames Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 568
Errors To display port statistics for IP address 192.168.255.10, slot 8, and GbE port 1: switch:admin> portstatsshow ip 8/ge1 192.168.255.10 ipaddr 192.168.255.10 IP address ip_out_octets 159896 Errors 0 IP TCP Data Checksum Errors 536 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 569
See Also portErrShow, portShow portStatsShow 2 Fabric OS Command Reference Manual 537 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 570
is to be swapped, relative to its slot for bladed systems. Examples To swap area numbers between a pair of ports: switch:admin> portswap 1/3 2/5 portswap done See Also portDisable, portEnable, portShow, portSwapDisable, portSwapEnable, portSwapShow, switchShow 538 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 571
of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To disable the portswap feature: switch:admin> portswapdisable See Also portSwap, portDisable, portEnable, portShow, portSwapEnable, portSwapShow, switchShow Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 572
of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To enable the portswap feature: switch:admin> portswapenable See Also portSwap, portDisable, portEnable, portShow, portSwapDisable, portSwapShow, switchShow 540 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 573
number. The default area number of a port is same as its switch port number. The execution of this command is subject to Admin Domain restrictions and information for ports whose area numbers have been swapped: switch:admin> portswapshow PortSwap is enabled Slot Slotport Swport Area 2 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 574
problems to a single replaceable element and isolate problems technology: a short-wavelength media (switch) port is connected to another types are supported: E_Ports F_Ports (must support ELS Echo) supported and it is asked to do so. If a request was made to test all possible ports on a given switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 575
Use the dataTypeShow command to view the types of pattern that are supported with portTest. dataTypeShow displays the pattern name, the pattern number to ports. Examples To run a functional test on an active switch: switch:admin> porttest -ports 1/1-1/3 See Also fportTest, loopPortTest, - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 576
help pages for further details. Examples To display information from portTest: switch:admin> porttestshow 1 Port 1 : PASS PortType: OTHER PortInternalState: INIT fportTest, loopPortTest, portLoopbackTest, portTest, spinFab, stopPortTest 544 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 577
may be in place. Operands none Examples To display the zone membership information of ports: switch:user> portzoneshow [OUTPUT TRUNCATED] PORT: 160 (160) Offline PORT: 161 (161) Offline defaultHard: 0 IFID: See Also cfgShow, switchShow Fabric OS Command Reference Manual 545 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 578
order. Whenever a power supply goes out of service or a field-replaceable unit (FRU) is CP boards' processors to cease execution of the firmware. In this situation, all operation of the system of the display varies, depending on the switch model and the number of slots present. Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 579
5th 3 9 6th 2 8 7th 1 7 8th Proceed to change the POL order? (yes, y, no, n): [no] y See Also chassisShow, powerOffListShow, psShow, slotPowerOff, slotPowerOn, slotShow Fabric OS Command Reference Manual 547 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 580
power causes the CP boards' processors to cease executing the firmware. In this situation, all operation of the system terminates immediately Operands none Examples To display the slot power off list order: switch:admin> powerofflistshow Slot 10 will be powered off 1st Slot 9 Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 581
that may be in place. Operands none Examples To view the status of the power supplies: switch:admin> psshow Power Supply #1 is OK DELTA DPS-1001AB-1E 23000000601 S1 Power Supply #2 is IXD0111000120 See Also chassisShow, fanShow Fabric OS Command Reference Manual 549 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 582
displayed on the switch's console. Only telnet session will be suppressed. By default, quiet mode is disabled, and all switch tasks may send and then enable it: switch:admin> quietmode quietMode: On Usage: quietMode 0|1 0: to turn it off 1: to turn it on switch:admin> quietmode 0 Committing - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 583
the Standby CP: switch:admin> reboot -f Warning: This command is being run on a control processor (CP) based system and will cause the active CP to reboot. Are you sure you want to reboot the active CP [y/n]? See Also fastboot, switchReboot, hafailover Fabric OS Command Reference Manual 551 53 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 584
Operands none Examples To display a list of routing-related commands: switch:admin> routehelp bcastShow dlsShow fspfShow interfaceShow iodShow LSDbShow nbrStateShow topologyShow uRouteShow See Also bcastShow, interfaceShow, uRouteShow 552 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 585
staff. The information displayed might not be supported between releases and is subject to change arbitrarily. Operands none Examples To display the size of the active security database: switch:admin> secactivesize Size of security active data: 35 bytes (Max 262144 bytes) See Also secDefineSize - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 586
saved persistently. New data is effective with the next authentication request. The configuration applies to a switch instance only. A Brocade Security license is required to run this command in non-secure as to peer. (continued on next page) 554 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 587
keys. If a fabric requires authentication, deleting this database may cause switch to segment from the fabric. Do want to remove secret key database? (yes, y, no, n): [no] y Deleting secret key database... Done. switch:admin> See Also none Fabric OS Command Reference Manual 555 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 588
CSR). • Delete a CSR. • List the certificates present in the switch. • Display the contents of a certificate/CSR. • Delete a specific certificate. • Configure SSL certificate file name. • Enable secure protocols. The operands are as follows: 556 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 589
switch. delcsr Deletes the CSR in the switch. showcsr Displays the contents of the CSR in the switch switch. Use this for the following: Download a certificate issued by a CA after sending the CSR to the CA. Download : switch:admin To generate a CSR: switch:admin> seccertutil gencsr Country - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 590
CSR: switch:admin> seccertutil delcsr WARNING!!! About to delete the switch CSR. above. To import a certificate: switch:admin> seccertutil import Select protocol and enable option: switch:admin> seccertutil import switch:admin> seccertutil showcsr To display contents of a certificate: switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 591
staff. The information displayed might not be supported between releases and is subject to change arbitrarily. Operands none Examples To display the size of the defined security database switch:admin> secdefinesize Size of security defined data: 35 bytes (Max 262144 bytes) See Also secActiveSize - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 592
sw2 Primary 10:00:00:60:69:22:32:83 3 Ready 0.0.0.0 sw3 Secured switches in the fabric: 3 IPV6 configured switches may have a link local address, an optional statically configured IPv6 address and up to IPv4 address information. 560 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 593
2 See Also To display security related fabric information on the Primary FCS switch with IPV6 and IPV4 address configurations: primaryfcs:admin> secFabricShow Role WWN DId 106 "mps_daz_2" 1080::8:800:200C:417A secPolicyDump, secPolicyShow Fabric OS Command Reference Manual 561 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 594
switch. Operands none Examples To enable a backup FCS switch to take over as the primary FCS switch: switch:admin> secfcsfailover This switch is about to become the Primary FCS switch. All transactions of the current Primary FCS switch 562 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 595
specific support staff only. The information displayed might not be supported between releases and is subject to change arbitrarily. Operands Examples none To view the current security state: switch Try to remove dom 1 switch 00:00:00:00:00: 90:02:6a (local switch) Stamp 1427583424 ----The - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 596
0 ----wwnDL State----domain 1 state 6 domain 2 state 6 domain 10 state 6 pid tid key sec usec --------- LOG CACHE --------- See Also secActiveSize, secDefineSize 564 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 597
mode Displays whether secure mode is enabled or disabled Sets the admin passwd for non-FCS switches Aborts changes to defined policy Activates all policy sets Adds members to an existing policy Creates Resets version stamp See Also none Fabric OS Command Reference Manual 565 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 598
command can be issued only in secure mode and only from the primary FCS switch. Operands none Examples To disable secure mode: primaryfcs:admin> secmodedisable Please enter n): [no] y See Also secFabricShow, secModeEnable, secModeShow 566 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 599
switches in the fabric. This command fails if any switch one or more specified FCS switches is present in the fabric switches are present in the fabric, the command can be issued on any switch switches for the FCS policy. The list of switches must be enclosed in quotation marks, and each member switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 600
, the session becomes interactive and the user is prompted to enter FCS switch members and passwords. If the --currentpwd option is not used, the session FCS switches specified by domain, WWN, and switch name: primaryfcs:admin> secmodeenable 568 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 601
the Root and Factory accounts may be required for proper support of the switch. Ensure the Root and Factory passwords are documented in switch root password: Re-type new password: Changing password for factory New FCS switch factory password: Re-type new password: Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 602
for user New fabric wide user password: Re-type new password: Changing password for admin New Non FCS switch admin password: Re-type new password: Broadcast message from root Thu Feb 26 02:58:52 2004... you obtained this software and do 570 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 603
(yes, y, no, n): [no] y This command requires Switch Certificate, Security license and Zoning license to be installed on every switch in the fabric. NOTE: On successful completion of this command, , secModeDisable, secModeShow, secPolicyShow Fabric OS Command Reference Manual 571 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 604
the WWN of the FCS switch. DId Displays the domain of the FCS switch. swName Displays the switch name of the FCS switch. This command can be issued on any switch in a fabric. Operands none Also secFabricShow, secModeDisable, secModeEnable 572 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 605
Non FCS switch admin password: Re-type new password: Login sessions with password changed will be terminated. Password for non-FCS admin account has been changed successfully. See Also passwd, secModeDisable, secModeEnable, secModeShow, secTempPasswdSet Fabric OS Command Reference Manual 573 53 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 606
policy. When secure mode is enabled, this command can be issued only from the Primary FCS switch. When in non-secure mode, this command can be issued for ACL policy management. NOTE , secPolicyDump, secPolicyRemove, secPolicySave, secStatsShow 574 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 607
mode is enabled, this command can be issued only from the primary FCS switch. Any modifications to SCC DB and DCC DB are saved and activated. When secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow Fabric OS Command Reference Manual 575 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 608
this command can be issued only from the Primary FCS switch. The secpolicyadd command can be issued on all switches for SCC and DCC policies as long as fabric-wide • IPF_POLICY • FCS_POLICY The specified policy name must be capitalized. 576 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 609
of devices associated with a specific switch and port combination. An empty DCC_POLICY does not stop access to the switch. The device is specified with a WWN string. The switch and port combination must be in the following format: switch port Fabric OS Command Reference Manual 577 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 610
5 and all devices attached to those ports. [*] Selects all ports on the switch and devices currently attached to those ports. OPTIONS_POLICY members "NoNodeWWNZoning" is the only option , secPolicyDump, secPolicyRemove, secPolicySave 578 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 611
Each DCC_POLICY_nnn must each have a unique name. This command can be issued on all switches in the current fabric for SCC and DCC policies if it is not fabric-wide. • SCC_POLICY • OPTIONS_POLICY • AUTH_POLICY • IPF_POLICY • FCS_POLICY Fabric OS Command Reference Manual 579 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 612
is a list of devices associated with a specific switch and port combination. An empty DCC_POLICY does not stop access to the switch. The device is specified with a WWN string. The switch and port combination must be in the following format: switch port switch port can be specified using WWN - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 613
switches in the fabric are non-FCS switches. Out of the FCS list, the switch that is in the first position becomes the Primary FCS switch and the remaining switches become back-up FCS switches. If the first switch , secPolicySave, secStatsShow Fabric OS Command Reference Manual 581 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 614
when FCS policy is enabled on the switch in base FOS, this command can be issued only from the Primary FCS switch. Operands This command has the following operands fabric-wide switch access through that method is unrestricted. Examples To delete an existing security policy: switch:admin> - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 615
secPolicyDelete 2 See Also Are you sure (yes, y, no, n):[no] y MS_POLICY has been deleted. secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow Fabric OS Command Reference Manual 583 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 616
(saved) databases. When secure mode is enabled, this command can be issued from all the FCS switches in the fabric. Operands This command has the following operands: "listtype"Specify which database to display. :60:69:30:15:5c 1 primaryfcs 584 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 617
.13 192.155.52.11 ACTIVE POLICY SET TELNET_POLICY IpAddr 192.155.52.0 secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyRemove, secPolicySave, secPolicyShow Fabric OS Command Reference Manual 585 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 618
after activation. This command can be issued in secure mode from the Primary FCS switch.It is supported in non-secure mode for FCS policy management. Operands This command has the secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow 586 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 619
mode is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operands: "name" Specify the name of members can be specified using IP address, WWN, domain, or switch name. IP Address Member Policy Types The following policy types require - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 620
specific switch and port combination. The device is specified with a WWN string. The switch and port combination must be specified in the following format: can be specified using WWN, domain, or switch on the switch. [3, 9] switch MS policy: switch:admin> secpolicyremove - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 621
secPolicySave, secStatsShow secPolicyRemove 2 Fabric OS Command Reference Manual 589 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 622
switch. This command is always a local switch operation. When secure mode is enabled, this command saves Defined Security Policy to persistent memory on all switches in the fabric and can be issued only from the primary FCS switch. NOTE persistent memory: switch:admin> secpolicysave - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 623
command displays the security policy database in effect on all the FCS switches in the fabric and can be issued from all FCS switches. In non-secure mode, this command displays the security policy database displays only SCC and DSS policies. Fabric OS Command Reference Manual 591 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 624
192.155.52.0 See Also To display all security policies from defined databases: switch:admin> secpolicyshow "defined DEFINED POLICY SET FCS_POLICY Pos Primary WWN DId swName 1 , secPolicyDump, secPolicyRemove, secPolicySave 592 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 625
to 0. This command can be issued to any switch. If issued on the primary FCS switch, this command can reset security statistics for any or all switches in the fabric. Operands This command has the DCC_POLICY violations are grouped together. Fabric OS Command Reference Manual 593 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 626
statistics. Specify an asterisk (*) to represent all switches in the fabric or specify a list of domains is the local switch. Examples To reset all statistics on the local switch: switch:admin> secstatsreset About statistics on domains 1 and 69: switch:admin> secstatsreset "DCC_POLICY", "1;69" - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 627
This command can be issued to any switch. If issued on the primary FCS switch, this command can retrieve and display the security statistics for any or all switches in the fabric. This command displays security name must be all capitalized. Fabric OS Command Reference Manual 595 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 628
all switches switch): switch:admin> secstatsshow "TELNET_POLICY", "*" Fabric Statistics: Domain 1: Name Value TELNET_POLICY 0 Domain 69: Name Value TELNET_POLICY 0 Domain 70: Name Value TELNET_POLICY 0 secFabricShow, secStatsReset 596 Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 629
switch switches. If they are temporarily activated by secTempPasswdSet, those accounts are disabled by secTempPasswdReset or by rebooting the switch switch. Operands This command has the following operands: domain Specify the domain of the switch -switch root primary-switch:admin> - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 630
this command to set a unique temporary password for a given account on a specific switch in the fabric. Use the secTempPasswdReset command to remove the temporary password or reboot the switch. You can change any password on any switch. To change the password of an account that has higher level than - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 631
from management application problems. This command switch:admin> sectransabort Transaction has been aborted. See Also secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secStatsShow Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 632
to 0: switch:admin> secversionreset About to reset version stamp to 0. Are you sure (yes, y, no, n):[no] y done. Security Policy Version Stamp has been set to 0. See Also secFabricShow, secModeDisable, secModeEnable, secModeShow, secTransAbort 600 Fabric OS Command Reference Manual 53-1000436 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 633
Admin Domain restrictions that may be in place. Operands none Examples To view all sensor values: switch:admin> sensorshow sensor 1: (Temperature) is Ok, value is 39 C sensor 2: (Temperature) Supply ) is Absent See Also fanShow, tempShow Fabric OS Command Reference Manual 601 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 634
volume of messages, degrading the system response time. The set of supported modules and their current debug levels are displayed by the command dbgShow To set debug level of module named NS to value 3: switch:admin> setdbg NS 3 switch:admin> dbgshow NS Module NS, debug level = 3, verbose level - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 635
the FR4-18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other feature operations. This displays. Examples To display the ESD mode: switch:admin> setesdmode -show Esd Mode is 0 (Disabled). See Also spinSilk Fabric - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 636
. -show Specify the -show operand to display the current setting. This operand is optional. Examples To enable the media mode: switch:admin> setgbicmode 1 GBIC mode is now 1 (Enabled). See Also itemList, miniCycle, setMediaMode, setSfpMode, spinJitter, spinSilk 604 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 637
-show Specify the -show operand to display the current setting. This operand is optional. Examples To display the media mode: switch:admin> setmediamode -show Media mode is now 0 (disabled). See Also itemList, miniCycle, setGbicMode, setSfpMode, spinJitter, spinSilk Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 638
setmodem [-e] | [-d] Description Use this command to enable or disable modem dial-in to a CP on those systems that support modem dial-in. When modem dial-in is enabled, you can log in to a CP through a modem, and in to the standby CP. . . . 606 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 639
: -e Specifies that modem dial-in be enabled. -d Specifies that modem dial-in be disabled. Examples To disable modem dial-in to a CP: switch:admin> setmodem -d disabling modem, please wait, this can take a couple of minutes... modem disabled See Also none 2.015 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 640
operand to display the current setting. This operand is optional. Examples To enable, disable, and then display the media mode: switch:admin> setsfpmode 0 SFP mode is now 0 (disabled). See Also itemList, miniCycle, setGbicMode, setMediaMode, spinJitter, spinSilk 608 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 641
might be useful to isolate internal switch problems from SFP problems since the internal paths are in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other a two-port loopback: switch:admin> setsplbmode -show Splb Mode is 0 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 642
names are case sensitive. level Specify the verbose level (0 to 9). Examples To set the verbose level of module named NS to value 3: switch:admin> setverbose NS 3 switch:admin> dbgshow NS Module NS, debug level = 0, verbose level = 3 See Also dbgShow, setDbg 610 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 643
this command displays values described in the "Gigabit Interface Converter" spec by Sun Microsystems, et al. Use the -all operand any SFP replacement actions are made while a port or a switch is disabled. Operands This command has the following operands: slotnumber Manual 611 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 644
Power: 235.2 uWatts To display detailed information for GbE port 0 on a Brocade 7500: switch:admin> sfpshow ge0 Identifier: 3 SFP Connector: 7 LC Transceiver: 050c402000000000 100,200_MB/s M5, : 0 Serial No: A00107001 Date Code: 020313 612 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 645
Min: 0 Serial No: A00143427 Date Code: 020511 To display all SFP information: switch:user> sfpshow -all Port 0: Identifier: 3 SFP Connector: 7 LC Transceiver: 050c402000000000 100,200_MB/s M5,M6 sw Inter_dist Encoding: 1 8B10B Fabric OS Command Reference Manual 613 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 646
: 0 (units nm) Options: 001a Loss_of_Sig,Tx_Fault,Tx_Disable BR Max: 5 BR Min: 5 Serial No: 21P70530005BW Date Code: 01062301 (output truncated) switchShow 614 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 647
CP. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To disable flow control: switch:admin> shellflowcontroldisable Disabling flowcontrol flow control is now disabled See Also shellFlowControlEnable Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 648
the console output is suspended for an extended period of time, the switch might reboot. It is recommended to disable the flow control, using shellFlowControlDisable place. Operands none Examples To enable flow control: switch:admin> shellflowcontrolenable Enabling flowcontrol flow control is now - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 649
. Description This command is not supported on this platform as of FOS 5.1 - use slotPowerOff. The execution of this command is subject to Admin Domain restrictions that may be in place. See Also slotShow, slotPowerOff, bladeDisable Fabric OS Command Reference Manual 617 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 650
slotPowerOn. Description This command is not supported on this platform as of FOS 5.1 - use slotPowerOn. The execution of this command is subject to Admin Domain restrictions that may be in place. See Also slotShow, slotPowerOn, bladeEnable 618 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 651
operand: slotnumber Specify the slot number of the blade to be powered down. This operand is required. Examples To power off blade unit 3: switch:admin> slotpoweroff 3 Slot 3 is being powered off See Also powerOffListSet, powerOffListShow, slotPowerOn, slotShow Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 652
the following operand: slotnumber Specify the slot number of the blade to be powered on. This operand is required. Examples To power on blade unit 3: switch:admin> slotpoweron 3 Powering on slot 3. See Also slotPowerOff, slotShow 620 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 653
Displays the physical slot number. Blade Type Displays the blade type: SW BLADE The blade is a switch. CP BLADE The blade is a control processor. UNKNOWN Blade not present or its type is not the preboot power on self tests). Fabric OS Command Reference Manual 621 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 654
may be in place. Operands none Examples To display the status of all slots in the system: switch:user> slotshow Slot Blade Type ID Status 1 SW BLADE 17 FAULTY 2 SW BLADE 17 DISABLED , chassisShow, slotPowerOff, slotPowerOn 622 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 655
command to verify the intended functional operation of the switch by sending SERDES BIST patterns from port N's transmitter, count requested is reached. All ports are marked bad. This command is supported only on Brocade 200E, 4100, and 48000 platforms. The execution of Manual 623 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 656
Refer to itemList for further details. Examples To test the serial link of the following port path: switch:admin> sltest -ports 0/5-0/31 -speed 4 -lb_mode 1 passcnt 1 Running Port sltest .... passed. , itemList, portRegTest, spinSilk 624 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 657
switch. The configuration includes SNMPv1 and SNMPv3 configuration, access control list (ACL), MIB capability, and system group. It supports -domain systems, this command is specific to the SNMP agent associated with the current switch. The execution of this command Manual 625 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 658
of role snmpadmin and three entries of role snmpuser are supported. Separate default passwords are provided for creation of authKey primary and nonprimary switches individually and unlike community strings, user name and passwords is not distributed for other switches in the Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 659
is yes. SW-TRAP Specifying yes means the SNMP management application can receive SW-TRAPS from the switch. The default value is yes. Users can also turn on or off individual SW Traps. The individual the SW traps. The default value is 'no'. Fabric OS Command Reference Manual 627 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 660
End User Premise. The contact information for this system (switch). The default value is set as Field Support. Refer to the definition of sysDescr, sysLocation and sysContact parameters include MIBs and traps supported by the SNMP agent. 628 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 661
) No trap recipient configured yet To set the SNMPv1 configuration of a switch: switch:admin> snmpConfig --set snmpv1 SNMP community and trap recipient configuration: Community , f): [true] Access host subnet area in dot notation: [0.0.0.0] Fabric OS Command Reference Manual 629 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 662
agtCfgSet, agtCfgShow, snmpMibCapSet, snmpMibCapShow SW_v5_x.mib, "Switch Management Information & Switch Enterprise Specific Trap" RFC1157, "A Simple Network Management Protocol ( version 3 of the Simple Network Management Protocol (SNMPv3)" 630 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 663
on the desired traps individually. See the Fabric OS MIB Reference Manual for more information. The execution of this command is subject to Admin the options for configuring SNMP MIB traps: switch:admin> snmpmibcapset The SNMP Mib/Trap Capability has been set to support FE-MIB SW-MIB FA-MIB FICON- - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 664
] HA-TRAP (yes, y, no, n): [yes] fruStatusChanged (yes, y, no, n): [yes] cpStatusChanged (yes, y, no, n): [yes] fruHistoryTrap (yes, y, no, n): [no] agtCfgDefault, agtCfgSet, agtCfgShow 632 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 665
the SNMP MIBs and traps capability of the SNMP agent in the switch. FA-MIB Specifying yes means the user can access FA-MIB variables configuration. The values can be changed, if user download the configuration data through configDownload command. All the new Reference Manual 633 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 666
may be in place. Operands none Examples To display the options for configuring the SNMP MIB capability: switch:admin> snmpmibcapshow FE-MIB: YES SW-MIB: YES FA-MIB: YES FICON-MIB: NO HA-MIB agtCfgDefault, agtCfgSet, agtCfgShow, snmpConfig 634 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 667
links between switches. At the switch might be verified, as can be the The switch remains switch and media. If these pass, the fault lies in the cable or remote switch switches that support trunking, then it is likely that trunk groups are present and all ports between the two switches - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 668
2 spinFab -setfail mode Instruct spinFab how to mark failed ports. -nmegs count. This mode is disabled by default. Examples To test cascading ISL links: switch:admin> spinfab -ports 1/0 - 1/2 spinfab running... spinfab: Completed 11 megs, status: Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 669
See Also camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, spinSilk, sramRetentionTest spinFab 2 Fabric OS Command Reference Manual 637 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 670
23 47 For details about the procedures used in this test, refer to spinSilk. The command is supported only on Brocade 200E, 3250, 3850, 3900,4100, 24000, and 48000 platforms; use portLoopbackTest or miniCycle odd ports' speed for 2 Gbit/sec. 638 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 671
used. Refer to itemList for further details. Examples To measure line-speed jitter: switch:admin> spinjitter -ports 1/0 - 1/2 Running SpinJitter One moment please ...Ports Segmented ERR_STAT_2LONG ERR_STAT_BADEOF ERR_STAT_BADOS Fabric OS Command Reference Manual 639 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 672
the Fabric OS Message Reference for more information. See Also backport, camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest 640 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 673
this command to verify the intended functional operation of the switch, at the selected speed, by configuring the routing hardware termination do not achieve synchronization and the test fails. The command is supported only on Brocade 200E, 3250, 3850, 3900,4100, and 24000 Manual 641 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 674
results of portLoopbackTest and spinSilk, can be used to determine which components of the switch are faulty. The execution of this command is subject to Admin Domain restrictions that may 3 Silkscreen loopback 5 Internal (parallel) loopback 642 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 675
user ports to test. By default, all of the user ports in the current switch are tested. Refer to itemList for further details. Examples To perform a functional test on selected ports : OFF blade4: Beacon: OFF Area Slot Port Gbic Speed State Fabric OS Command Reference Manual 643 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 676
the Fabric OS Message Reference for more information. See Also backport, camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinJitter, sramRetentionTest 644 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 677
executed on an operational switch. You must first disable the switch using the switchDisable command. The command is supported only on Brocade 200E data retention test: switch:admin> sramretentiontest 2 Running SRAM Retention Test ... passed. Fabric OS Command Reference Manual 645 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 678
Refer to the Fabric OS Message Reference for more information. See Also camTest, centralMemoryTest, cmemRetentionTest, cmiTest, dataTypeShow, itemList, portLoopbackTest, spinSilk 646 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 679
the FR4-18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other feature operations. This is 0. Examples To clear port and diagnostic statistics: switch:admin> statsclear -bports 1/10-1/62 -use_bports 1 See Also itemList - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 680
switch using the switchDisable command. There is a link table that stores 16 pairs of SID-DID address. Each of the SID-DID pairs is named a link. This table is used for gathering statistics that match the link. This command is supported . 648 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 681
See Also camTest, itemList statsTest 2 Fabric OS Command Reference Manual 649 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 682
place. Operands This command has the following operand: -ports itemlist Specify a list of user ports to test. By default, all the user ports in the switch are tested. Refer to itemList help pages for further details. Examples To stop the portTest command - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 683
Without operands, the command syntax is displayed. Examples To display the FFDC configuration: switch:admin> supportffdc --show First Failure Data Capture (FFDC) is disabled. To enable the FFDC events: switch:admin> supportffdc --enable First Failure Data Capture (FFDC) is enabled. See Also none - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 684
-s -h 192.168.67.126 -u anonymous -d tracedump supportftp: ftp parameters changed. To display the FTP parameters: switch:admin> supportftp Host IP Addr: 1080::8:800:200C:417A User name: njoe Remote Dir: support FTP Auto check: Off 652 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 685
auto file transfer: switch:admin> supportftp -e support auto file transfer enabled. See Also To disable auto file transfer: switch:admin> supportftp -d support auto file transfer disabled. supportSave, supportShow, traceDump supportFtp 2 Fabric OS Command Reference Manual 653 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 686
data, and other support information Synopsis supportsave core file, FFDC data and other support information to a remote FTP location. BP blades installed in the switch, it will also retrieve support file (as a .tar. with various scp mode services. Because the supportSave command will - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 687
command. Failure to pretest and properly configure the service could result in significant delays in obtaining transferred support information for switch:routing1, module:NS_evlog... .../supportSave_files/routing1-S6-200508280208-NS_evlog.ss: 1.62 kB 551.19 B/s Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 688
trace dump files transfered after this command. OK to proceed? (yes, y, no, n): [no] Host IP: 192.168.1.1 User Name: admin Password: ***** Remote Directory: tmp Saving support information for switch:routing1, module:RASLOG... 656 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 689
support information for switch:routing1, module:RCS_Log... ...portSave_files/routing1-S6-200508280207-RCS_Log.ss: 4.65 kB 1.55 kB/s Saving support information for switch .ss: 2.72 kB 928.95 B/s Saving support information for switch:routing1, module:FSPF_Log... ...e_files/routing1-S6-200508280208 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 690
Displays switch information for debugging purposes. Synopsis supportshow [[slotnumber/]portnumber1-portnumber2] [lines] Description Use this command to display support information fabric (ENABLED by default) fabricShow islShow trunkShow 658 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 691
fabPortShow fspfShow nbrStateShow fcpLogShow zone stateshow portZoneShow cfgShow cfgSize rcssmshow rcsInfoShow rcsregistryshow zone mergeshow zone stateshow services (ENABLED by default) fdmiCacheShow fdmiShow nsShow nsAllShow nscamShow nscamShow -t ns portshow security (ENABLED by default) authUtil - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 692
sensorShow psShow licenseShow portFlagsShow portCfgShow portErrShow fwSamShow agtCfgShow slotShow (product-dependent) slotShow -d576 emtraceshow emtraceshow2 emhsmtraceshow systraceshow -d fwAlarmsFilterShow chassisShow timeout 660 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 693
-A FC-FC Routing (DISABLED by default) fcrProxyDevShow fcrProxyConfig fcrXlateConfig fcrPhyDevShow fcrRouteShow fcrFabricShow fcrResourceShow FCIP (DISABLED by default) portShow fciptunnel ge$k all Fabric OS Command Reference Manual 53-1000436-01 supportShow 2 661 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 694
. If the slotnumber/portnumber parameter is omitted, all ports in the switch display in the per-port outputs. The slotnumber must be provided when supportSave, supportShowCfgDisable, supportShowCfgEnable, supportShowCfgShow, traceDump, traceTrig 662 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 695
supportshowcfgdisable [os | exception | port | fabric | services | security | network | portlog | systemextend | filter the fabric group commands services Disables the service group commands security Disables under the supportShow command: switch:admin> supportshowcfgdisable os Config update - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 696
supportshowcfgenable [os | exception | port | fabric | services | security | network | portlog | system | Enables the fabric group commands services Enables the service group commands security Enables the commands under the supportShow command: switch:admin> supportshowcfgenable os Config update - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 697
Examples To display which groups of commands are enabled in thesupportShow command: switch:admin> supportshowcfgshow os enabled exception enabled port enabled fabric enabled services enabled security enabled network enabled portlog enabled system enabled extend disabled filter - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 698
mode. This operand is optional. If no operand is specified, the current value is displayed. Examples To turn beaconing mode on: switch:admin> switchbeacon 1 See Also To turn beaconing mode off: switch:admin> switchbeacon 0 switchShow 666 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 699
switch. All Fibre Channel ports are taken offline. If the switch was part of a fabric, the remaining switches reconfigure. The switch disabled switch can be temporarily enabled using the switchEnable command. A temporarily enabled switch disable a switch persistently: switch:admin> - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 700
. The switch might need to be enabled if it was previously disabled to make configuration changes or to run diagnostics. If the switch is connected assigns itself a domain ID. If another switch assumes the principal role, then this switch becomes a subordinate switch, and accepts a domain ID from the - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 701
switch to a particular level. The configuration is saved in flash memory and persists across switch reboots or power cycles. If any port on the switch level for all ports on a switch: switch:admin> switchcfgspeed 0 Committing configuration...done. See Also portCfgSpeed, portShow Fabric OS - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 702
disable trunking on all the ports on this switch. This operand is required. Examples To enable trunking on a switch: switch:admin> switchcfgtrunk 0 Committing configuration...done. See Also portCfgShow, portCfgTrunkPort, portShow, switchShow 670 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 703
switch. All Fibre Channel ports are taken offline; if the switch was part of a fabric, the remaining switches reconfigure. The switch require the switch to be disabled send an error if invoked while the switch is enabled. The switch does not need To disable the switch: switch:admin> switchdisable - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 704
this switch remains the principal switch, then it assigns itself a domain ID. If another switch assumes the principal role, then this switch becomes a subordinate switch and Operands none Examples To enable a switch: switch:admin> switchenable See Also switchCfgPersistentDisable, - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 705
switch name. All switches have a symbolic name that is primarily used for switch management. This name is shown in the Fabric OS CLI prompt, under each switch switch name. Enter this command with no operand to display the current switch name. Changing the switch switch name for the switch. name can - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 706
switch without disrupting the other switch in a dual-switch chassis. This command is equal to running switchShutdown. This command is not supported up kernel modules...Done. Initializing kernel modules...Done. Starting all switch daemons...Done. Powering on slot 1...Done. Powering on slot 4...Done - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 707
switch and port status information. Information might vary by switch switch Switch summary information is as follows: switchName The switch's symbolic name. switchType The switch's model and revision numbers. switchState The switch The switch summary relative to the switch. Index column is - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 708
diagnostics. Locking to the reference signal. Running diagnostics. Connection not established (for virtual ports only). Port is up and running. 676 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 709
support ISCSI. FCIP Ports support FCIP. comment The comment field is blank, or displays: Disabled Port is disabled. Bypassed Port is bypassed (loop only). Loopback Port is in loopback mode. E_Port Fabric port; displays WWN and name of attached switch edge switch. Brocade 7600 switch, if - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 710
. Also, switchShow displays WWN of the of the border switch attached to this N_Port as a 24-bit Port Identifier assigned to this port by the enterprise fabric. To display Disabled (Persistent) Disabled (Persistent) Disabled (Persistent) F-Port 678 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 711
VE-Port VE-Port VE-Port To display a switch in Access Gateway mode: switch:admin> switchName: switchType: switchState: switchMode: switchWwn: switchBeacon: switchshow switch 34.0 Online Access Gateway Mode 10:00:00: , switchEnable, switchName Fabric OS Command Reference Manual 679 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 712
switchShutdown Not supported on this platform. Synopsis Description switchshutdown This command is not supported on this platform as of FOS 5.1. The execution of this command is subject to Admin Domain restrictions that may be in place. 680 Fabric OS Command Reference Manual 53-1000436 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 713
switchStart Not supported on this platform as of Fabric OS 5.1. switchStart 2 Fabric OS Command Reference Manual 681 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 714
the switch policies: switch:admin> switchstatuspolicyset To change the overall switch status policy parameters The current overall switch status policy parameters: Down Marginal PowerSupplies 2 1 Temperatures 2 1 Fans 2 1 WWN 0 1 CP 0 1 682 Fabric OS Command Reference Manual 53 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 715
the ** prompt is (0..0), the policy parameter is NOT applicable ** to the switch. Simply hit the Return key. The minimum number of Bad PowerSupplies contributing to : (0..64) [1] (output truncated) switchStatusPolicyShow, switchStatusShow Fabric OS Command Reference Manual 683 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 716
a status change in the switch. The command displays the current switch. For example, if the FaultyPorts DOWN parameter is set to 3, and three ports fail in the switch, then the status of the switch none Examples switch:admin> switchstatuspolicyshow The current overall switch status policy - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 717
MissingSFPs 0 0 See Also switchStatusPolicySet, switchStatusShow switchStatusPolicyShow 2 Fabric OS Command Reference Manual 685 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 718
Fabric Watch license are able to view the list of unhealthy ports. This command displays the overall switch status, and the status of the following contributors: Power supplies Temperatures Fans WWN servers (dual CP HEALTHY HEALTHY HEALTHY 686 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 719
healthy To retrieve a switch health report for a switch that is configured with an IPv4 address: switch:user> switchstatusshow Switch Health Report Switch Name: switch IP address: 10.32 switchStatusPolicySet, switchStatusPolicyShow Fabric OS Command Reference Manual 687 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 720
this command to display the current time and the amount of time that the switch has been operational. The execution of this command is subject to Admin Domain . Operands none Examples To view the uptime for the switch: switch:user> switchuptime 9:50pm up for 20 mins See Also switchReboot, switchShutdown - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 721
from 0 through 7. This operand is optional; if omitted, the current facility is displayed. Examples To set the syslog facility to LOG_LOCAL1: switch:admin> syslogdfacility -l 1 Syslog facility changed to LOG_LOCAL1 See Also syslogdIpAdd, syslogdIpRemove, syslogdIpShow Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 722
are configured, the switch forwards all error log entries to the syslogd on the specified server(s). Up to six servers are supported. The syslogdipadd command the list of machines to which system messages are sent: switch:admin> syslogdipadd 1080::8:800:200C:417A See Also errShow, syslogdFacility - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 723
syslogd. This operand is required. Examples To remove the address 1080::8:800:200C:417A from the list of machines to which system messages are sent: switch:admin> syslogdipremove 1080::8:800:200C:417A See Also errShow, syslogdFacility, syslogdIpAdd, syslogdIpShow Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 724
subject to Admin Domain restrictions that may be in place. Operands none Examples To display all syslog daemon IP addresses: switch:admin> syslogdipshow syslog.IP.address.1 1080::8:800:200C:417A See Also errShow, syslogdFacility, syslogdIpAdd, syslogdIpRemove 692 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 725
the active CP, standby CP, and any AP blades. After doing this, you need to manually power off the system. If you want to reboot the system, manually turn the power switch on. This command is not supported on the standby CP. The execution of this command is subject to Admin Domain restrictions that - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 726
switch. You are required to power-cycle the switch in order to restore operation. Are you sure you want to shutdown the switch down for system halt NOW !! INIT: Switching to runlevel: 0 INIT: Sending processes the standby CP: switch:admin> sysshutdown Shut down the whole system is not support from the - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 727
displays. The burn-in tests are designed to operate with switches connected to a fabric and restrict the frame loopback to inside FAN, and WWN; however, only BLADE is supported at this time. Since only one FRU type is supported, this parameter is optional, but -unit is Manual 695 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 728
slk_all_nmegs : 50 systemverification: Arming the burnin run on switch 0. systemverification: Starting burnin on Switch 0 systemverification: Monitoring progress of the burnin activity. burninErrShow, burninStatus, diagSetBurnin, diagSetCycle 696 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 729
), the sensor state, and the temperature. The temperature readings are given in both Centigrade and Fahrenheit. Refer to the hardware reference manual for your switch to determine the normal temperature range. The execution of this command is subject to Admin Domain restrictions that may be in place - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 730
login timeouts. This operand is optional; if omitted, the command displays the current timeout value. Examples To set the idle timeout to 10 minutes: switch:admin> timeout 10 IDLE Timeout Changed to 10 minutes The modified IDLE Timeout will be in effect after NEXT login See Also none 698 Fabric - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 731
[domain] Description Use this command to display the fabric topology, as it appears to the local switch, including: A list of all domains that are part of the fabric, and to each of Examples To display the unicast fabric topology: Fabric OS Command Reference Manual 699 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 732
by port: 5 Local Translate Domain 8 owned by port: 4 Domain: 6 Metric: 500 Name: switch Path Count: 4 Hops: Out Port: In Ports: Total Bandwidth: Bandwidth Demand: Flags: 1 60 D See Also fcrXlateConfig, portRouteShow, uRouteShow 700 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 733
dump, or to display the dump status on the switch. If there is no parameter specified, this command defaults dumps will be generated, one with .dmp for the main switch and one with .tar.gz for the embedded BP. The 5: switch:admin> tracedump -n -s 5 See Also To remove a trace dump: switch:admin> - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 734
is subject to Admin Domain restrictions that may be in place. Examples To display information on the track-changes commands: switch:admin> trackchangeshelp trackChangesSet Configure alert for login/logout/config update trackChangesShow Displays status of track changes See Also trackChangesSet - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 735
output from the track-changes feature is dumped to the error log for the switch. Use errDump or errShow to view the error log. The execution of enable the track-changes feature: switch:admin> trackchangesset 1, 1 Committing configuration...done. switch:admin> trackchangesshow Track changes status: - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 736
output from the track-changes feature is dumped to the error log for the switch. Use the errDump command or errShow command to view the error log. The Examples To display the status of the track-changes feature: switch:admin> trackchangesshow Track changes status: ON Track changes generate SNMP - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 737
Switch does not support trunking Trunking license required Trunking not supported in switch port port_id connect to different switches port port_id and port port_id connect to the switch WWN port port_id is connection: switch:admin> trunkdebug 43 44 Switch does not support trunking switch:admin> - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 738
switch switches switches switch and WWNs of the remote switches . See EXAMPLES, below. deskew The time difference for traffic to travel over each ISL compared to the time to the shortest ISL in the group. The number corresponds to nanoseconds divided by 10. The firmware switch: switch: switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 739
17 MASTER 4 deskew 16 4 deskew 16 4 deskew 16 4 deskew 17 4 deskew 17 4 deskew 15 4 deskew 16 switch:admin> switchshow 48 4 0 013000 id N4 Online EX-Port (Trunk port, master is Slot 4 Port 1 ) 49 13 "SW4900_43" portCfgTrunkPort, switchCfgTrunk Fabric OS Command Reference Manual 707 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 740
switch switch (when the security feature is enabled) connect to the NTP server and broadcast time service updates. All switches NTP server used must support a full NTP client supports a full NTP from the switch. When a switches to view the NTP server switch Primary FCS switch as teh clock - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 741
See Also Updating Clock Server configuration...done. switch:admin> tsclockserver 123.123.123.123 date tsClockServer 2 Fabric OS Command Reference Manual 709 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 742
reporting and logging. An incorrect time zone setup does not affect the switch operation in any way. System services started during the switch boot reflect time-zone change only at the next reboot. The time zone or 30. This operand is optional. 710 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 743
timezone to the zone that is used on the west coast of America, using interactive mode: switch:admin> tsTimeZone --interactive Please identify a location so that time zone rules can be set correctly. to quit ?45 (continued on next page) Fabric OS Command Reference Manual 711 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 744
Yes 2) No Enter number or control-D to quit ?1 System Time Zone change will take effect at next reboot To revert back to the old format: switch admin> tstimezone --old 2 switch admin> tsttimezone Time Zone Hour Offset: 2 Time Zone Minute Offset: 0 See Also date 712 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 745
to the itemList command help page for more information. Examples To execute this test: switch:admin> turboramtest -passcnt 2 -ports 2/0-2/63 Running Turbo RAM Test ........ passed. Diagnostics , cmiTest, portRegTest, sramRetentionTest Fabric OS Command Reference Manual 713 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 746
paths between the chips within a mini-switch. This is done by configuring all of the ports on the mini-switch in internal loopback and sending a frame , the first seven frames use unique data type. This command is supported only on Brocade 200E,3250, 3850, 3900,4100, 24000, and Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 747
first error. The default value is 0. -ports itemlist Specify a list of user ports to test. By default, all of the user ports in the current switch are tested. This option can be used to restrict testing to the specified ports. To run the txdPath test: Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 748
2 txdPath switch:admin> txdpath Running TX Data Path Test .... Test Complete: "txdpath" Pass 10 of 10 Duration 0 hr, , camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest 716 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 749
is subject to Admin Domain restrictions that may be in place. Operands none Examples To display the length of time the system has been operational: switch:admin> uptime 12:03am up 4:56, 3 users, load average: 1.17, 1.08, 1.08 See Also date, fastboot, reboot Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 750
route that is assigned to a specific path (defined by port number , load sharing might be affected. The switch attempts to achieve optimum load sharing, but is not supported on Brocade domain 2 to go through port 5: switch:admin> urouteconfig 1 2 5 done. switch:admin> urouteshow 1/1 2 Local Domain - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 751
the destination domain of the static route to remove. Examples To remove a static route for all traffic coming in from port 1 and addressed to domain 2: switch:admin> urouteremove 1 2 done. See Also configShow, dlsShow, uRouteConfig, uRouteShow Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 752
(PID Format 2) on a switch, the value is equal to the Area field displayed by the switchShow command. Refer to Fabric OS Administrator's Guide for more information regarding the extended routing information for all input ports in the switch. 720 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 753
of all the active ports: switch:admin> urouteshow Local Domain ID: To display the routing information of port 11 on slot 1: switch:admin> urouteshow 1/11 Local Domain ID: 3 In Port Domain the routing information of port 11 to domain 4 only: switch:admin> urouteshow 1/11, 4 Local Domain ID: 3 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 754
accounts are allowed only on the Primary FCS switch. The Primary FCS switch distributes the update to the entire Fabric. As a result, all switches supporting customer-defined accounts will have the same account the SecurityAdmin or Admin role. 722 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 755
is not allowed in secure mode. --delete username Delete an existing account named username from the switch. This action does not take any options. It prompts for the confirmation before proceeding. Once runs the userConfig --delete command. Fabric OS Command Reference Manual 723 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 756
description of the user account named username, on the switch. The -r option changes the role of the account Fabric OS, when certain operations cause a switch to delete some of its customer created accounts on the switch-local user database only, regardless of whether the switch is configured - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 757
switch : switch:admin AD 4: switch:admin> userConfig --add switch:admin> userConfig --change bob -a 128,129 To Add AD 0 & 255 to bob's AD member list. Home AD is unchanged: switch :admin> userConfig --addad bob -a 0,AD255 To Delete AD 128 from bob's AD member list. New home AD is set to 0: switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 758
to the Brocade-specific default of user before enabling security; otherwise, the switch is not allowed in the secure fabric. This command is not supported on all platforms. name from "USERID" to "admin": switch:admin> userrename USERID admin See Also secModeEnable 726 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 759
switch Fabric OS Made on Displays the build date of firmware running in switch Flash Displays the build date of firmware stored in flash proms BootProm Displays the version of the firmware the switch starts running flash firmware at the firmware version information in a switch: switch:admin> - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 760
you to reboot the system (or switch on dual-domain systems), because the change does not take effect until the switch restarts. This reboot can be deferred, or reboot to propagate the change to all switch components. However, the restart of the switch must happen before any firmwareDownload or (for - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 761
follows a batched-transaction model. Users can perform a specific zone operation using the --copy, --expunge, and --validate that are not part of the current zone enforcement table. If a switch is specified using D,P in the Admin Domain membership list, all zone elements Manual 729 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 762
configuration from the root zone database (AD0) to the current Admin Domain: switch:admin> zone --copy AD0.cur_cfg1 To copy backup_zn zone from the root zone database (AD0) to the current Admin Domain: switch:admin> zone --copy AD0.backup_zn 730 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 763
switch:admin> zone --expunge "100,5" To delete all reference of zone backup_zn: switch:admin> zone --expunge backup_zn To delete all reference of zone alias backup_ali1: switch : switch:admin> zone --validate -m 0 To validate all zones in the zone database in the persistent storage: switch:admin - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 764
existing zone. This command changes the defined configuration. For the change to be preserved across switch reboots, it must be saved to non-volitile memory using the cfgSave command. For the See Also zoneCreate, zoneDelete, zoneRemove, zoneShow 732 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 765
defined with the members "2,12; 2,14; 10:00:00:60:69:00:00:8a" would contain all devices connected to switch 2, ports 12 and 14, and to the device with the World Wide Name "10:00:00:60:69:00:00:8a is usually meant for servers and not for storage Fabric OS Command Reference Manual 733 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 766
by semicolons. Quotation marks are required. Can be one or more of the following: A switch domain and port area number pair: for example, "2, 20". View the area numbers loop1; 1,2; array2" See Also zoneAdd, zoneDelete, zoneRemove, zoneShow 734 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 767
. For the change to be preserved across switch reboots, it must be saved to flash memory command can be issued only from the primary FCS switch. Operands This command has the following operand: "zonename delete the zone "Blue_zone": switch:admin> zonedelete "Blue_zone" See Also zoneAdd - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 768
restrictions that may be in place. Operands none Examples To display zone command help information: switch:admin> zonehelp aliAdd aliCreate aliDelete aliRemove aliShow Add a member to a zone alias Create transaction See Also none 736 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 769
and member specifications. This command switch:admin> cfgshow "*" cfg: UK_cfg Red_zone; White_zone; Blue_zone cfg: USA_cfg Red_zone; White_zone; Blue_zone See Also cfgAdd, cfgClear, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow, zoneObjectRename Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 770
21:00:00:20:37:0c:76:85; 21:00:00:20:37:0c:71:df switch:admin> zoneobjectexpunge "White_zone" switch:admin> cfgshow Defined configuration: cfg: USA_cfg Red_zone; Blue_zone zone: Blue_zone 1,1; array1; 1,2; , zoneObjectCopy, zoneObjectRename 738 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 771
and member specifications. This switch:admin> zoneobjectrename "USA_cfg", "UK_cfg" switch:admin> cfgshow "*" cfg: UK_cfg Red_zone; White_zone; Blue_zone See Also cfgAdd, cfgClear, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow, zoneObjectCopy Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 772
the change to be preserved across switch reboots, it must be saved to issued only from the primary FCS switch. Operands This command has the be one or more of the following: A switch domain and port area number pair: for example, "array2" from "Blue_zone": switch:admin> zoneremove "Blue_zone", - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 773
. When secure mode is enabled, this command can be issued on any FCS switch in the fabric. Operands This command has the following operands: "pattern" A To display all zones beginning with the letters "A" through "C": switch:admin> zoneshow "[A-C]*" zone: Blue_zone 1,1; array1; 1,2; array2 See - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 774
2 zoneShow 742 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 775
Watch, Trunking, or Performance Monitoring, refer to the Fabric OS Administrator's Guide. Advanced Zoning Commands The following commands are available with the purchase of member from a zone. Displays zone information. Copies a zone object. Fabric OS Command Reference Manual 743 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 776
Fabric Assist zone information. NOTE The Fabric Assist Mode is only available on Fabric OS v2.6.x and v3.x systems in the fabric; it is not supported on Fabric OS v4.x or v5.x. 744 Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 777
Command Description portCfgLongDistance Configures a port to support long-distance links. Fabric Watch Commands switch status. Displays the policy parameters that determine overall switch status. Displays overall switch status. Displays temperature readings. Fabric OS Command Reference Manual - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 778
OS Administrator's Guide. TABLE 5 Brocade Trunking Commands Command Description portCfgTrunkPort switchCfgTrunk trunkDebug Configures a port for trunking. Configures a switch for trunking. monitor. Deletes an end-to-end monitor on port. 746 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 779
Fabric OS Administrator's Guide. TABLE 7 third-party PKI-based certificates in the switch. Displays the size of the defined security database a backup FCS switch to take over as primary FCS switch. Displays the current Sets the admin password for non-FCS switches. Aborts all changes to the defined database that have - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 780
policy. Saves a defined security policy to flash memory on all switches in the fabric. Displays an existing security policy. Resets security statistic policies. Resets a password on a remote switch. Sets a temporary password on a remote switch. Aborts current security transaction. Resets the - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 781
primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Can be run on all FCS switches. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Fabric OS Command Reference Manual 749 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 782
the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Can also be run on a single non-FCS switch which is segmented from a fabric. Community strings can be changed on the primary FCS switch only 750 Fabric OS Command Reference Manual 53-1000436 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 783
be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Fabric OS Command Reference Manual 751 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 784
4 Commands Exclusive to the Primary FCS 752 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 785
to nonvolatile memory. firmwareDownload Downloads firmware onto switch. firmwareDownloadStatus Displays the progress and status of a firmware download. firmwareRestore Restores the old firmware in the switch. firmwareShow Displays firmware versions in the switch. h Displays shell history - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 786
(CP). supportSave Saves support information for RASLOG, TRACE, and supportShow. switchName Displays this switch's name. tsClockServer Displays time zone. upTime Displays how long switch has been up. version Displays firmware version. 754 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 787
" on page 758 supportShow Control Commands The supportShow command is used to display support information by executing groups of preselected Fabric OS and Linux commands. The information group of commands from displaying under supportShow. Fabric OS Command Reference Manual 755 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 788
portRouteShow fabricShow islShow trunkShow topologyShow fabStateShow fabSwitchShow fabStatsShow fabPortShow fspfShow fcplogshow zone-stateshow portzoneshow portCamShow cfgSize cfgShow rcssmshow rcsinfoshow rcsregistryshow 756 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 789
Command Groups (Continued) Command Group Fabric OS v3.2.0 services nsShow nsAllShow nscamShow security network portlog secModeShow secPolicyDump secStatsShow secFabricShow /bin/df /sbin/ifconfig /sbin/route /bin/hostname portLogDump Fabric OS Command Reference Manual 757 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 790
ptcreditshow ptDataShow ptPhantomShow ptPropShow ptStatsShow filterportshow ps_dump -a -n port# NOTE Many of the commands executed by supportShow are intended for support use only. These commands are not intended for end-users. Proc Entry Information Displayed The os command group prints a number - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 791
2 pty 3 ttyp 4 ttyS 5 cua 7 vcs 10 misc 89 i2c 90 mtd 128 ptm 136 pts 162 raw 245 swd 246 ham 247 fc 248 fc-switch 249 fabsys 250 fss_kt 251 fss_data 252 fss_mgmt 253 portlog 254 platform Block devices: 1 ramdisk 3 ide0 7 loop Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 792
Active: 23464 kB Inactive: 49472 kB HighTotal: 0 kB HighFree: 0 kB LowTotal: 126700 kB LowFree: 31896 kB SwapTotal: 0 kB SwapFree: 0 kB 760 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 793
I/O at 0x1000 [0x1003]. I/O at 0x2000 [0x2007]. I/O at 0x3000 [0x3003]. I/O at 0x4000 [0x400f]. Bus 0, device 6, function 0: Non-VGA unclassified device: Brocade Communications Systems, Inc. Bloom switch (rev 0). IRQ 26. ---- Fabric OS Command Reference Manual 761 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 794
0 1060300 0 disk_io: (3,0):(61121,5352,115463,55769,944835) ctxt 44089966 btime 1048729603 processes 17684 /proc/tty/drivers /proc/tty/drivers serial /dev/cua 5 64-65 serial:callout serial /dev/ttyS 4 64-65 serial pty_slave /dev/pts PST 2003 762 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 795
Domain. 4. Command-specific: checks such as whether the command is supported on the platform for Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin N O/OM OM N O N O OM O OM O OM O O O O O O O O O O Fabric OS Command Reference Manual 763 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 796
Command Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin aptPolicy auditCfg OM N OM O O OM OM OM N OM O N OM OM/N N N OM OM N N O N N N N N N N N N O O O O O O O O O O O O O N N 764 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 797
Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin chassisShow chipRegShow N OM O N N OM N N N OM N OM O OM O O N OM O N O OM O O N OM O N O OM O O N OM O N Fabric OS Command Reference Manual 765 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 798
User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin N OM N O N O N O N OM N O N O N O N O N O N O N O N O O OM O O O O O O O O O O O O N O OM O N O N O N 766 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 799
N = none/not available) Command Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin fcpLogClear O OM OM OM N OM O OM OM OM O OM O O firmwareRestore O OM OM OM O OM O O Fabric OS Command Reference Manual 767 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 800
Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security N O N O N O N O OM O N O N O N O N O N O N O N OM OM O O O O O O O O O O O O O O O O OM OM O N O N O N OM OM 768 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 801
User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin O N O OM O N O N O N O N O N O N OM OM O O O OM O O OM N O O O O O N OM OM OM OM O N O O O N O N O N Fabric OS Command Reference Manual 769 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 802
User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin O N OM OM O N O N O N O N O N O N O N O N O O N OM OM OM N OM O N O N O N O N O N O N O N O N O N 770 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 803
-modify, N = none/not available) Command Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin perfCfgClear O OM O OM N OM O N perfCfgRestore N portCfgShow O OM OM OM N OM OM N Fabric OS Command Reference Manual 771 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 804
available) Command Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin portCfgSpeed portCfgTrunkPort portcfgvexport portcmd O OM OM N O OM OM OM N OM O N O OM OM OM N OM O N 772 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 805
Command Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin portStatsShow OM N OM O OM O OM O OM O OM O OM OM OM O OM O OM O OM O OM O OM O OM O OM O OM O OM Fabric OS Command Reference Manual 773 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 806
, N = none/not available) Command Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin secPolicyDump O OM N O N OM O OM OM OM OM N OM O N statsTest O OM OM OM N OM O N 774 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 807
N = none/not available) Command Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin stopPortTest O OM OM OM N OM O N N N N N N N OM trackChangesSet O OM OM OM O OM O OM Fabric OS Command Reference Manual 775 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 808
) Command Name User Admin Operator Switch Admin Zone Admin Fabric Admin Basic Switch Admin Security Admin trackChangesShow O OM N O N N OM OM OM N OM O O O OM O O O O O O O O O OM O O O O O O O O O O 776 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 809
services , 643, 675, 715 Brocade 200E switch, 83, 107, 245, 348, switch, 59, 86, 233, 245 Brocade 3016 switch, 292 Brocade 3250 switch, 44, 57, 59, 84, 245, 464, 466, 519, 638, 641, 645, 648, 714 Brocade 3850 switch 648, 714 Brocade 4100 switch, 44, 83, 107, switch, 168, 169, 464 Brocade 7500 switch - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 810
708, 709 command line interface, 1 commands supported on the active CP, 753 commands supported on the standby CP, 753 committed traffic rate , 448 DLS, see dynamic load sharing DMA test, 194 domain name service, 142 dual CP system active CP and supportFTP, 654 dual-domain systems Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 811
FDMI, 221, 222 Fibre Channel Association, xxv Fibre Channel Extended Link Service, 185, 245, 506, 542 Fibre Channel Protocol, 191, 192 419, 421, 422, 423, 427 filterTest AL_PA, 233 firmware download, 235, 236, 240, 241 firmware version, 222, 244, 727 FL_Port, 126, 191, Manual 53-1000436-01 Index 3 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 812
98, 248, 249, 311, 319, 320, 322, 323, 326, 330, 332, 379, 383, 386 ISL Inter-Switch Link, 425 ISL Trunking, 477, 670 ISL Trunking commands, 746 ISL, see interswitch link H HA, see high availability haDump 420, 421, 423, 426, 429, 431, 432, Index 4 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 813
settings, 101, 102, 152, 445, 446, 461, 464, 466, 470, 473, 677 LSAN, see logical SAN lsanZoneShow zoning, 350 LSR, see link state record M MAC address, 88, 294, 452 Management Server, 77, 78 572, 573, 574, 575, 586, 587, 590, 593, 595, 597, Fabric OS Command Reference Manual 53-1000436-01 Index 5 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 814
, 108, 205, 357, 358, 512, 623, 638, 642, 715 serial port, 151, 336, 347, 373, 606, 615, 616 setMediaMode, 605 Index 6 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 815
587, 588, 673 switch speed, 669 switchBeacon, 666 switchShow, 677 SW-TRAP, 627, 630, 631, 632, 633, 634 syslog, 146, 689, 690, 692 sysShutdown active CP, 693 system services, 105, 710 729 zone alias, 33 adding, 32 T Tape Pipelining, 526 Fabric OS Command Reference Manual 53-1000436-01 Index 7 - HP StorageWorks 2/128 | Brocade Fabric OS Command Reference Manual - Supporting - Page 816
fcPing, 185 enabling zone configuration, 69 ISL R_RDY, 461 licensed commands, 743 zoning operation parameters, 104 zoning transaction aborting, 75 Index 8 Fabric OS Command Reference Manual 53-1000436-01
53-1000436-01
15 Jun 2007
Fabric OS
Command Reference Manual
Supporting Fabric OS v5.3.0