HP StorageWorks 2/128 Brocade Fabric OS Command Reference Manual - Supporting - Page 356
To modify the port parameters, To display the port information in verbose mode
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 356 highlights
2 iscsiPortCfg NOTE This parameter only supports FC4-16IP blades in Brocade 48000 directors. geport -h Specifies the port number of a GbE port to be configured in the specified slot. Use -h on any option to display the help text for it. Examples To modify the port parameters: switch:admin> iscsiportcfg --modify 7/ge2 -e 2 -c 2 -f 32768 The operation completed successfully. To display the port information in verbose mode: switch:admin> iscsiportcfg --show 7/ge0 The configured port parameters for slot 7 and port ge0 are: Header Digest: Off Data Digest: Off First Burst Length: 512 Error Recovery Level: 0 Immediate Data: Off Connections per session: 1 Num. of active sessions on port: 1 Port Statistics: iSCSI in PDU: iSCSI in Octet: iSCSI out PDU: iSCSI out Octet: FCP in PDU: FCP in Octet: FCP out PDU: FCP out Octet: iSCSI Command: iSCSI R2T: iSCSI Data In: iSCSI Data Out: iSCSI Response: FCP Command: FC Data In: FC Data Out: FC XFer Ready: FC Response: iSCSI Error PDU: FC Error PDU: iSCSI Snack: iSCSI NOP Out: iSCSI Text: iSCSI Logout: iSCSI Task Mgmt.: iSCSI TM Response: iSCSI Abort Task: iSCSI Abort Task Set: iSCSI Clear ACA: iSCSI Clear Task Set: iSCSI LUN Reset: iSCSI Target Reset: 211 32592 307 77484 205 76356 114 29944 104 11 11 96 104 103 91 11 11 103 0 0 0 0 1 1 0 0 0 0 0 0 0 0 324 Fabric OS Command Reference Manual 53-1000436-01