HP StorageWorks 2000fc HP StorageWorks P2000 G3 MSA System Event Description R - Page 9

View other logged events to determine other action to take.

Page 9 highlights

56 Informational A controller has powered up or restarted. Recommended actions • No action required. 58 Warning A disk drive or enclosure management processor (EMP) detected a serious error, such as a parity error or disk hardware failure. Recommended actions • If the event indicates that a disk or an expansion module is bad, replace the indicated device. Informational A disk drive or enclosure management processor (EMP) detected a non-serious error. Recommended actions • No action required. 59 Warning The controller detected a parity error while communicating with the indicated SCSI device. The error was detected by the controller, not the disk. Recommended actions • If the event indicates that a disk or an expansion module is bad, replace the indicated device. Informational The controller detected a non-parity error while communicating with the indicated SCSI device. The error was detected by the controller, not the disk. Recommended actions • No action required. 60 Informational A disk channel was reset from another initiator or target. Recommended actions • No action required. 61 Error The controller reset the indicated disk channel to recover from a communication error. This event is logged to identify an error trend over time. Recommended actions • If the controller recovers, no action is required. • View other logged events to determine other action to take. 62 Warning The indicated global or dedicated spare disk has failed. Recommended actions • Replace the failed disk. 65 Error An uncorrectable ECC error occurred on the buffer memory on startup. The controller is automatically restarted and its cache data is restored from the partner controller's cache. Recommended actions • Replace the controller module. HP StorageWorks P2000 G3 MSA System Event Descriptions Reference Guide 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

HP StorageWorks P2000 G3 MSA System Event Descriptions Reference Guide
9
56
Informational
A controller has powered up or restarted.
Recommended actions
No action required.
58
Warning
A disk drive or enclosure management processor (EMP) detected a serious error, such as a parity error or
disk hardware failure.
Recommended actions
If the event indicates that a disk or an expansion module is bad, replace the indicated device.
Informational
A disk drive or enclosure management processor (EMP) detected a non-serious error.
Recommended actions
No action required.
59
Warning
The controller detected a parity error while communicating with the indicated SCSI device. The error was
detected by the controller, not the disk.
Recommended actions
If the event indicates that a disk or an expansion module is bad, replace the indicated device.
Informational
The controller detected a non-parity error while communicating with the indicated SCSI device. The error
was detected by the controller, not the disk.
Recommended actions
No action required.
60
Informational
A disk channel was reset from another initiator or target.
Recommended actions
No action required.
61
Error
The controller reset the indicated disk channel to recover from a communication error. This event is logged
to identify an error trend over time.
Recommended actions
If the controller recovers, no action is required.
View other logged events to determine other action to take.
62
Warning
The indicated global or dedicated spare disk has failed.
Recommended actions
Replace the failed disk.
65
Error
An uncorrectable ECC error occurred on the buffer memory on startup. The controller is automatically
restarted and its cache data is restored from the partner controller’s cache.
Recommended actions
Replace the controller module.