Page 5 highlights

• Fixed an issue where SAS port values were reported incorrectly. • Fixed issues with cold temperature monitoring. • Fixed an issue where a drive that reports a SMART error may not be downed appropriately. • Fixed a problem where a drive failure during initialization could cause a controller to crash. • Fixed a problem where a controller was brought down by a disk reset from the partner controller. • Fixed the licensing engine to prevent an invalid license from loading. • Fixed an issue where an uncorrectable ECC error caused a controller to crash. • Fixed an issue where a controller would stop responding when disks with media errors are in the system. • Fixed an issue that lead to a vdisk faulting when controller A was replaced. • Fixed an issue where a vdisk using mirroring would fail to initialize when the maximum size was requested. • Fixed a problem where a controller crash could be triggered by switching the owning controller of a vdisk when snapshot volumes were resident on the vdisk. • Fixed an issue where the controller would stop responding when a snapshot with a duplicate name was requested. • Fixed an issue where a RAID 10 vdisk in quarantine had a utility would fix a parity error even though there was a missing member of the vdisk. • Fixed a problem where an erroneous SuperCap failure was reported. • Fixed a rare issue where controller temperature was displayed incorrectly . • Fixed an issue where the default LUN was not released for reuse when the owning volume was deleted in a single controller array. • Fixed an issue of inconsistent behavior when moving drives from one drive enclosure to another drive enclosure. • Fixed an issue on RAID 10 and RAID 50 vdisks that kept spares from being deleted. • Fixed an issue that lead the enclosure health status to be reported incorrectly. • Improved the initialization time for RAID 1 and RAID 10 vdisks. • Fixed an error on the iSCSI controller where a controller pair would lose connection and force one of the controllers to shut the other down. • Fixed an issue where LUNs were presented in both PDA (Peripheral Device Addressing) and VSA (Volume Set Addressing) modes. • Fixed an issue with SNMP incorrectly reporting certain traps. • Fixed a problem where the loop IDs of the controllers were not properly displayed. • Fixed an issue where part and serial number were not displayed correctly. • Fixed a problem where online help was formatting incorrectly (CLI). • Added a function to allow SNMP test traps to be sent (CLI). • Fixed a problem that caused enabling NTP to fail because of an improper condition (CLI). • Fixed an issue where set disk-parameters was not accepting valid input (CLI). (Example: set disk-parameters smart off) • Fixed an issue where a set job-parameters utility-priority command returned an error of "Error: Invalid FC topology" (CLI). • Fixed an issue that lead to inconsistent vdisk status reporting (CLI). • Fixed various cosmetic issues (GUI). • Fixed an issue where changing volume names allowed the user to change the name to a volume that is already in use (GUI). • Fixed Help to provide the correct location for Save Logs feature (GUI). HP StorageWorks MSA2000 G2 Firmware Release Notes 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

Fixed an issue where SAS port values were reported incorrectly.
Fixed issues with cold temperature monitoring.
Fixed an issue where a drive that reports a SMART error may not be downed appropriately.
Fixed a problem where a drive failure during initialization could cause a controller to crash.
Fixed a problem where a controller was brought down by a disk reset from the partner controller.
Fixed the licensing engine to prevent an invalid license from loading.
Fixed an issue where an uncorrectable ECC error caused a controller to crash.
Fixed an issue where a controller would stop responding when disks with media errors are in the
system.
Fixed an issue that lead to a vdisk faulting when controller A was replaced.
Fixed an issue where a vdisk using mirroring would fail to initialize when the maximum size was
requested.
Fixed a problem where a controller crash could be triggered by switching the owning controller
of a vdisk when snapshot volumes were resident on the vdisk.
Fixed an issue where the controller would stop responding when a snapshot with a duplicate name
was requested.
Fixed an issue where a RAID 10 vdisk in quarantine had a utility would fix a parity error even
though there was a missing member of the vdisk.
Fixed a problem where an erroneous SuperCap failure was reported.
Fixed a rare issue where controller temperature was displayed incorrectly .
Fixed an issue where the default LUN was not released for reuse when the owning volume was
deleted in a single controller array.
Fixed an issue of inconsistent behavior when moving drives from one drive enclosure to another
drive enclosure.
Fixed an issue on RAID 10 and RAID 50 vdisks that kept spares from being deleted.
Fixed an issue that lead the enclosure health status to be reported incorrectly.
Improved the initialization time for RAID 1 and RAID 10 vdisks.
Fixed an error on the iSCSI controller where a controller pair would lose connection and force
one of the controllers to shut the other down.
Fixed an issue where LUNs were presented in both PDA (Peripheral Device Addressing) and VSA
(Volume Set Addressing) modes.
Fixed an issue with SNMP incorrectly reporting certain traps.
Fixed a problem where the loop IDs of the controllers were not properly displayed.
Fixed an issue where part and serial number were not displayed correctly.
Fixed a problem where online help was formatting incorrectly (CLI).
Added a function to allow SNMP test traps to be sent (CLI).
Fixed a problem that caused enabling NTP to fail because of an improper condition (CLI).
Fixed an issue where
set disk-parameters
was not accepting valid input (CLI). (Example:
set disk-parameters smart off
)
Fixed an issue where a
set job-parameters utility-priority
command returned an
error of "Error: Invalid FC topology" (CLI).
Fixed an issue that lead to inconsistent vdisk status reporting (CLI).
Fixed various cosmetic issues (GUI).
Fixed an issue where changing volume names allowed the user to change the name to a volume
that is already in use (GUI).
Fixed Help to provide the correct location for Save Logs feature (GUI).
HP StorageWorks MSA2000 G2 Firmware Release Notes