HP StorageWorks 2000sa HP StorageWorks MSA2000 G2 Firmware Release Notes (5088 - Page 5
error of Error: Invalid FC topology CLI., HP StorageWorks MSA2000 G2 Firmware Release Notes
View all HP StorageWorks 2000sa manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
• Fixed an issue where SAS port values were reported incorrectly. • Fixed issues with cold temperature monitoring. • Fixed an issue where a drive that reports a SMART error may not be downed appropriately. • Fixed a problem where a drive failure during initialization could cause a controller to crash. • Fixed a problem where a controller was brought down by a disk reset from the partner controller. • Fixed the licensing engine to prevent an invalid license from loading. • Fixed an issue where an uncorrectable ECC error caused a controller to crash. • Fixed an issue where a controller would stop responding when disks with media errors are in the system. • Fixed an issue that lead to a vdisk faulting when controller A was replaced. • Fixed an issue where a vdisk using mirroring would fail to initialize when the maximum size was requested. • Fixed a problem where a controller crash could be triggered by switching the owning controller of a vdisk when snapshot volumes were resident on the vdisk. • Fixed an issue where the controller would stop responding when a snapshot with a duplicate name was requested. • Fixed an issue where a RAID 10 vdisk in quarantine had a utility would fix a parity error even though there was a missing member of the vdisk. • Fixed a problem where an erroneous SuperCap failure was reported. • Fixed a rare issue where controller temperature was displayed incorrectly . • Fixed an issue where the default LUN was not released for reuse when the owning volume was deleted in a single controller array. • Fixed an issue of inconsistent behavior when moving drives from one drive enclosure to another drive enclosure. • Fixed an issue on RAID 10 and RAID 50 vdisks that kept spares from being deleted. • Fixed an issue that lead the enclosure health status to be reported incorrectly. • Improved the initialization time for RAID 1 and RAID 10 vdisks. • Fixed an error on the iSCSI controller where a controller pair would lose connection and force one of the controllers to shut the other down. • Fixed an issue where LUNs were presented in both PDA (Peripheral Device Addressing) and VSA (Volume Set Addressing) modes. • Fixed an issue with SNMP incorrectly reporting certain traps. • Fixed a problem where the loop IDs of the controllers were not properly displayed. • Fixed an issue where part and serial number were not displayed correctly. • Fixed a problem where online help was formatting incorrectly (CLI). • Added a function to allow SNMP test traps to be sent (CLI). • Fixed a problem that caused enabling NTP to fail because of an improper condition (CLI). • Fixed an issue where set disk-parameters was not accepting valid input (CLI). (Example: set disk-parameters smart off) • Fixed an issue where a set job-parameters utility-priority command returned an error of "Error: Invalid FC topology" (CLI). • Fixed an issue that lead to inconsistent vdisk status reporting (CLI). • Fixed various cosmetic issues (GUI). • Fixed an issue where changing volume names allowed the user to change the name to a volume that is already in use (GUI). • Fixed Help to provide the correct location for Save Logs feature (GUI). HP StorageWorks MSA2000 G2 Firmware Release Notes 5