HP StorageWorks 4/256 Brocade Fabric OS Command Reference Guide v6.1.0 (53-100 - Page 640
command may be useful with large, counts. This mode is disabled
View all HP StorageWorks 4/256 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 640 highlights
2 spinFab -setfail mode Instruct spinFab how to mark failed ports. Specify 1 to mark failing ports as FAILED. Specify 0 not to mark failed ports as FAILED. This test normally logs errors but does not set the port status to FAILED. This parameter is provided to force the failing ports to be marked as FAILED in the same manner as other diagnostics. In test or qualification environments without live traffic, this command may be useful with large -nmegs counts. This mode is disabled by default. Examples To test cascading ISL links: switch:admin> spinfab -ports 1/0 - 1/2 spinfab running... spinfab: Completed 11 megs, status: passed. port 0 test status: 0x00000000 -- passed. port 1 test status: 0x00000000 -- passed. port 2 test status: 0x00000000 -- passed. Test Complete: "spinfab" Pass 10 of 10 Duration 0 hr, 0 min & 41 sec (0:0:41:877). passed. Diagnostics If the test detects failures, it may report one or more of the following error messages: DATA ERR_STAT ERR_STATS ERR_STATS_2LONG ERR_STATS_BADEOF ERR_STATS_BADOS ERR_STATS_C3DISC ERR_STATS_CRC ERR_STATS_ENCIN ERR_STATS_ENCOUT ERR_STATS_TRUNC ERR_STAT_2LONG ERR_STAT_BADEOF ERR_STAT_BADOS ERR_STAT_C3DISC ERR_STAT_CRC ERR_STAT_ENCIN ERR_STAT_ENCOUT ERR_STAT_TRUNC FINISH_MSG_ERR INIT MBUF_STATE_ERR NO_SEGMENT PORT_ABSENT PORT_DIED PORT_ENABLE PORT_M2M PORT_STOPPED PORT_WRONG RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT 614 Fabric OS Command Reference 53-1000599-02