HP StorageWorks 7110 HP StorageWorks Virtual Array va 7000 family - Installati - Page 49

Software Problems, PROBLEM, SOLUTION

Page 49 highlights

PROBLEM SOLUTION PROBLEM SOLUTION When installing a VA 7400, none of the disk enclosures are visible and one or more of the following errors occur: Data Unavailable Hot Spare Unavailable Capacity Depletion Catastrophic Redundancy Loss Missing Drive No Map Disks This is typically caused by failing to set all the FC Loop Speed switches on the DS 2405 LCCs to 1GB/s. Make sure the switch on every LCC is set to 1GB/s. You can quickly identify any LCC that is not set correctly by checking the 2G LED on the back of the disk enclosure. If the LED is on (green), the switch is set to 2GB/s and must be changed. When installing a VA 7400, a Phantom Enclosure warning state occurs. This is typically caused by installing a DS 2405 Disk System on an array with a controller firmware version earlier than HP14. Make sure the controller firmware is upgraded to the latest version. Software Problems PROBLEM SOLUTION Command View stops working when Secure Manager is enabled. Command View cannot manage the array. If Command View cannot communicate with array, it indicates that the host on which Command View is running does not have "Configure" (C) permissions on any LUN it can access on the array. Typically the LUN 0 entry in the LUN security table is used to grant Configure permission to all hosts. If access to LUN 0 is restricted, the host may no longer be able to use Command View to manage the array. Correcting this problem requires editing the array LUN security table. If there is another Command View host which can communicate with the array, you can use that host to edit the LUN security table. From the functioning host, perform the steps below. If there is not another Command View host, you will have to disable LUN security using the virtual front panel. For more information on using the virtual Virtual Array Installation Guide 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

Virtual Array Installation Guide
49
PROBLEM
When installing a VA 7400, none of the disk enclosures are
visible and one or more of the following errors occur:
Data Unavailable
Hot Spare Unavailable
Capacity Depletion
Catastrophic Redundancy Loss
Missing Drive
No Map Disks
SOLUTION
This is typically caused by failing to set all the FC Loop Speed switches on the
DS 2405 LCCs to 1GB/s. Make sure the switch on every LCC is set to 1GB/s.
You can quickly identify any LCC that is not set correctly by checking the
2G LED on the back of the disk enclosure. If the LED is on (green), the switch is
set to 2GB/s and must be changed.
PROBLEM
When installing a VA 7400, a Phantom Enclosure warning
state occurs.
SOLUTION
This is typically caused by installing a DS 2405 Disk System on an array with a
controller firmware version earlier than HP14. Make sure the controller
firmware is upgraded to the latest version.
Software Problems
PROBLEM
Command View stops working when Secure Manager is
enabled.
Command View cannot manage the array.
SOLUTION
If Command View cannot communicate with array, it indicates that the host on
which Command View is running does not have “Configure” (C) permissions
on any LUN it can access on the array. Typically the LUN 0 entry in the LUN
security table is used to grant Configure permission
to all hosts. If
access to
LUN 0 is restricted, the host may no longer be able to use Command View to
manage the array.
Correcting this problem requires editing the array LUN security table. If there is
another Command View host which can communicate with the array, you can
use that host to edit the LUN security table. From the functioning host, perform
the steps below.
If there is not another Command View host, you will have to disable LUN
security using the virtual front panel. For more information on using the virtual