HP StorageWorks 8/40 HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 67
Nonport side LED activity for FCoE Converged Network Switches
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
Slow blinking amber Receiving light or carrier, but (2 seconds) not online Verify that the diagnostic tests are not running. Re-enable the port using the portEnable command. Fast blinking amber (1/2 second) Port failure Check the management interface and the error log for details on the cause of the failure. Contact HP technical support if necessary. Steady green Online No action required. Slow blinking green (2 seconds) Online but segmented (loopback cable or incompatible switch) No action required. Fast blinking green (1/2 second) Internal loopback (diagnostic) No action required. Flickering green Online; frames flowing through port No action required. Nonport side LED activity for FCoE Converged Network Switches Figure 29 shows the LEDs on the nonport side of the switch. See Figure 8 on page 26 for power supply and fan assembly locations. 1. Power supply #2 status LED 2. Power supply #1 status LED 3. Fan assembly #3 status LED 4. Fan assembly #2 status LED 5. Fan assembly #1 status LED Figure 29 Nonport side LEDs on the FCoE Converged Network Switch 8-Gb SAN Switch hardware reference manual 67