Page 36 highlights

Table 4 Alarm events and recommended action (Continued) Icon Event ID and message Description Action (A3007.0001-000C) (value voltage sensor shows valueV - ALARM CLEAR) (A3008.0000) (The configuration area was damaged or a Remake Filesystem was performed from PROM mode. You must perform a 'config restore' to clear this error.) (A4000.0001) (threshold of value hit rising trigger trigger_number in value second window on port port_number ALARM SET (A6000.0002) (Configured port speed for port port_number not compatible with media.) (A6001.0001) (cmon: insufficient memory) (A6001.0003) (cmon: switch failed NDCLA) The out-of-range voltage condition has cleared. None The configuration area was damaged or a Remake Filesystem was performed from Maintenance mode. Enter the config restore command to clear the error. If this does not correct the problem, contact your authorized maintenance provider. The switch exceeded the specified threshold for the rising trigger in the specified sample window. Investigate the specified port for problems, or adjust the rising trigger or sample window. The transceiver in the named port is not capable of transmitting at the configured port speed. Reconfigure the port speed or replace the transceiver. The hotreset command has failed due to insufficient memory on the switch. The switch has been returned to its state before the hotreset command was entered. If acceptable, enter the reset switch command to reboot the switch. Contact technical support if a non-disruptive code load and activation is required. The Non-Disruptive Code Load and Activation (NDCLA) has failed. The switch has performed a hard reset. None 36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

36
(A3007.0001–000C)
(
value
voltage sensor
shows
value
V - ALARM
CLEAR)
The out-of-range voltage
condition has cleared.
None
(A3008.0000) (The
configuration area was
damaged or a Remake
Filesystem was
performed from PROM
mode. You must perform
a 'config restore' to
clear this error.)
The configuration area was
damaged or a Remake
Filesystem was performed
from Maintenance mode.
Enter the
config restore
command to clear the error. If
this does not correct the
problem, contact your
authorized maintenance
provider.
(A4000.0001)
(threshold
of
value
hit rising
trigger
trigger_number
in
value
second window
on port
port_number
-
ALARM SET
The switch exceeded the
specified threshold for the
rising trigger in the specified
sample window.
Investigate the specified port
for problems, or adjust the
rising trigger or sample
window.
(A6000.0002)
(Configured port speed
for port
port_number
not compatible with
media.)
The transceiver in the named
port is not capable of
transmitting at the configured
port speed.
Reconfigure the port speed or
replace the transceiver.
(A6001.0001) (cmon:
insufficient memory)
The
hotreset
command
has failed due to insufficient
memory on the switch. The
switch has been returned to
its state before the
hotreset
command was
entered.
If acceptable, enter the
reset switch
command
to reboot the switch. Contact
technical support if a
non-disruptive code load and
activation is required.
(A6001.0003) (cmon:
switch failed NDCLA)
The Non-Disruptive Code
Load and Activation (NDCLA)
has failed. The switch has
performed a hard reset.
None
Table 4
Alarm events and recommended action (Continued)
Icon
Event ID and message
Description
Action