HP StorageWorks Virtual Array 7100 Appendix A. Disk Array Controller Log - Page 6

HP StorageWorks Virtual Array 7100 Manual

Page 6 highlights

FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con Error! No text of specified style in document. Event Number (dec/hex) Event Name Predictive Maintenance Implication Suspected Components Description Logged? Mfg Fail? 70/0x46 71/0x47 72/0x48 73/0x49 74/0x4a 75/0x4b 76/0x4c 77/0x4d 78/0x4e 79/0x4f 80/0x50 81/0x51 82/0x52 83/0x53 84/0x54 85/0x55 86/0x56 87/0x57 88/0x58 Disk Interface Command Y N.A. None Y A backend device did not complete a command Timeout within the allotted time. Disk Interface Hot Plug N N.A. None N A command was aborted by a disk hotplug or by error error recovery for some other command. Host Write Collision With Y ignore - see None N A write launched from cache but ended with a non- Failed Cache Post accompanying SUCCESS status; this caused cache to mark the errors write cache entry as RETRY which means it is stuck in cache. A flush is required by a new FUA write. One of the pages from the flush is stuck in cache and the response is to fail the new write. Disk Drive Defect List Error Y Single Disk Drive N The disk drive returned a status of Occurrance CHECK_CONDITION, HARDWARE_ERROR, . The PDD's retries are exhausted or the I/O is not retryable. The drive may need to be formatted. Disk Drive Format Error Y Single Disk Drive N The disk drive returned a status of Occurrance CHECK_CONDITION, MEDIA_ERROR, FORMAT CORRUPTED/FAILED. May be cause for immediate failure. The PDD did not attempt to send a REASSIGN BLOCKS command. The drive may need to be formatted. Invalid/unsupported hierarchic N Ignore - Host None Y The host specified an 8-byte hierarchic LUN LUN reference LUN addressing reference that contained either an unsupported problem address mode or made use of hierarchy levels that the subsystem does not support. Disk Interface State Error Y N.A. None N The backend disk interface hardware or software state information was incorrect for observed activity. Write Sequence In Cache N N.A. None N A part of a write cache stream was aborted by the Broken By Host Abort host. The failed write was forced because the operation could not be completed. The host should retry the operation. Silent Disk Drive Error N N.A. None N On a previous attempt(s), the drive failed the I/O. Recovery (Usually due to hot plug.) The PDD retried the I/O and the drive returned good status. We do not log a recovered error because the original error was not logged. We report GOOD status to the host. Check Condition From Disk Y Single Disk Drive N The disk drive returned a check condition with no Drive With No Sense Occurrence sense data. The PDD's retries are exhausted or the I/O is not retryable. Disk Drive Failed Start Unit Y Single Disk Drive N The disk drive returned bad status for a start unit Command Occurrence command. The PDD's retries are exhausted. Unexpected Disk Drive Status Y Single Disk Drive, N The disk drive returned a status of SCSI_BUSY, Occurrance, Controller, Disk RESERVATION_CONFLICT, or some possible Interface undecodable status. The PDD's retries are compatibility exhausted or the I/O is not retryable. problem Insufficient resources for LUN N N.A. None N There is insufficient physical disk storage capacity operation. present for the LUN operation that was requested. More disks must be added to the subsystem before the operation can be successful. Microcode Changed Unit N N.A. None N New controller microcode was just installed. Attention Create LUN can't get LUN Y None allowed None Y The create LUN operation cannot be completed WWN seed because the memory device that holds the seed for the LUN WWN has either failed or cannot return the requested data. LUN WWNs cannot be made unique without this data. Recovered By Disk Drive On Y See drive vendor Disk Drive N On a previous attempt(s), the drive failed the I/O. Retry recommendation The PDD retried the I/O and the disk drive returned a status of CHECK_CONDITION, RECOVERED_ERROR Not ready, manual intervention N N.A. None Y The command is not possible in current subsystem required state. Data loss detected Y N.A. None Y An otherwise successful read op failed due to data loss recorded in at least 1 of the disk blks read This is a rev2 error; the error is defined but not used in rev1 firmware. Insufficient memory resources N N.A. None N There is not enough memory installed in the

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

FC-SCSI Interface Specification
Describes the IceCube SCSI interface. Targetted as part of OEM manual.
Disk Array Con
Error! No text of specified style in document.
Event
Number
(dec/hex)
Event
Name
Logged?
Predictive
Maintenance
Implication
Suspected
Components
Mfg Fail?
Description
70/0x46
Disk Interface Command
Timeout
Y
N.A.
None
Y
A backend device did not complete a command
within the allotted time.
71/0x47
Disk Interface Hot Plug
N
N.A.
None
N
A command was aborted by a disk hotplug or by
error error recovery for some other command.
72/0x48
Host Write Collision With
Failed Cache Post
Y
ignore - see
accompanying
errors
None
N
A write launched from cache but ended with a non-
SUCCESS status; this caused cache to mark the
write cache entry as RETRY which means it is stuck
in cache. A flush is required by a new FUA write.
One of the pages from the flush is stuck in cache
and the response is to fail the new write.
73/0x49
Disk Drive Defect List Error
Y
Single
Occurrance
Disk Drive
N
The disk drive returned a status of
CHECK_CONDITION, HARDWARE_ERROR, .
The PDD’s retries are exhausted or the I/O is not
retryable.
The drive may need to be formatted.
74/0x4a
Disk Drive Format Error
Y
Single
Occurrance
Disk Drive
N
The disk drive returned a status of
CHECK_CONDITION, MEDIA_ERROR,
FORMAT CORRUPTED/FAILED.
May be cause
for immediate failure. The PDD did not attempt to
send a REASSIGN BLOCKS command.
The drive
may need to be formatted.
75/0x4b
Invalid/unsupported hierarchic
LUN reference
N
Ignore - Host
LUN addressing
problem
None
Y
The host specified an 8-byte hierarchic LUN
reference that contained either an unsupported
address mode or made use of hierarchy levels that
the subsystem does not support.
76/0x4c
Disk Interface State Error
Y
N.A.
None
N
The backend disk interface hardware or software
state information was incorrect for observed
activity.
77/0x4d
Write Sequence In Cache
Broken By Host Abort
N
N.A.
None
N
A part of a write cache stream was aborted by the
host.
The failed write was forced because the
operation could not be completed. The host should
retry the operation.
78/0x4e
Silent Disk Drive Error
Recovery
N
N.A.
None
N
On a previous attempt(s), the drive failed the I/O.
(Usually due to hot plug.) The PDD retried the I/O
and the drive returned good status. We do not log a
recovered error because the original error was not
logged.
We report GOOD status to the host.
79/0x4f
Check Condition From Disk
Drive With No Sense
Y
Single
Occurrence
Disk Drive
N
The disk drive returned a check condition with no
sense data.
The PDD’s retries are exhausted or the
I/O is not retryable.
80/0x50
Disk Drive Failed Start Unit
Command
Y
Single
Occurrence
Disk Drive
N
The disk drive returned bad status for a start unit
command.
The PDD’s retries are exhausted.
81/0x51
Unexpected Disk Drive Status
Y
Single
Occurrance,
possible
compatibility
problem
Disk Drive,
Controller, Disk
Interface
N
The disk drive returned a status of SCSI_BUSY,
RESERVATION_CONFLICT, or some
undecodable status.
The PDD’s retries are
exhausted or the I/O is not retryable.
82/0x52
Insufficient resources for LUN
operation.
N
N.A.
None
N
There is insufficient physical disk storage capacity
present for the LUN operation that was requested.
More disks must be added to the subsystem before
the operation can be successful.
83/0x53
Microcode Changed Unit
Attention
N
N.A.
None
N
New controller microcode was just installed.
84/0x54
Create LUN can’t get LUN
WWN seed
Y
None allowed
None
Y
The create LUN operation cannot be completed
because the memory device that holds the seed for
the LUN WWN has either failed or cannot return the
requested data.
LUN WWNs cannot be made
unique without this data.
85/0x55
Recovered By Disk Drive On
Retry
Y
See drive vendor
recommendation
Disk Drive
N
On a previous attempt(s), the drive failed the I/O.
The PDD retried the I/O and the disk drive returned
a status of CHECK_CONDITION,
RECOVERED_ERROR
86/0x56
Not ready, manual intervention
required
N
N.A.
None
Y
The command is not possible in current subsystem
state.
87/0x57
Data loss detected
Y
N.A.
None
Y
An otherwise successful read op failed due to data
loss recorded in at least 1 of the disk blks read This
is a rev2 error; the error is defined but not used in
rev1 firmware.
88/0x58
Insufficient memory resources
N
N.A.
None
N
There is not enough memory installed in the