HP StorageWorks Virtual Array 7100 Appendix A. Disk Array Controller Log - Page 9

Event, Number, dec/hex

Page 9 highlights

Event Number (dec/hex) Event Name Predictive Maintenance Implication Suspected Components Description Logged? Mfg Fail? 122/0x7a 123/0x7b Hardware error prevents successful command completion Host Port Behavior Table overflow Y None of these are Unknown allowed Y None of these are Unknown allowed 124/0x7c 125/0x7d 126/0x7e 127/0x7f 128/0x80 129/0x81 130/0x82 131/0x83 132/0x84 133/0x85 134/0x86 135/0x87 Event Number (dec/hex) 256/0x100 Sequencer error injection error N These only occur Unknown in internal testing Test mode is required for this N These only occur Unknown command in internal testing Subsystem LUN configuration N Ignore None changed UA Mode parameters were restored N Ignore None from defaults UA Limit to supported number of Principals has been reached Disk Interface Error - no logging Disk Interface Error Y Ignore - Remove None unwanted associations from Security map N N.A. None Y N.A. None Disk Interface Command Y N.A. None Failed Host is not authorized to access Y LUN Cannot identify a FRU in Y phatom enclosure with id 0xff Journal Manager Buffer Write Y Failed Ignore - Host doesn't have permission to access LUN Ignore - Cannot identify FRU in phantom enclosure N.A. None None Journal Manager Journal Manager Stage Write Y N.A. Journal Failed Manager Event Name Access Time Count Error E Predictive Suspected v e nt L Maintenance Components o g g e d ? Implication Y Ignore. None 257/0x101 Disk Drive Placed In Failed State 258/0x102 NVRAM Image Out Of Date Y Single Disk Drive, Occurrance Controller, Back End FC Link Y Ignore - Operator None activity 259/0x103 No Quorum For Disk Set Access Y Ignore - Operator None activity or parameters stored there will probably revert to their default values. Y The command failed because a required access to hardware failed and was either not retried or was retried unsuccessfully. Y An attempt was made to add a new entry to the host port behavior table but no unused entry was available. An existing entry must be deleted to make room for the new entry. Y This error is used for a variety of purposes when injecting errors in sequencer module tests. Y The command that was received is only allowed when the test mode flag in the personality is true. N This error is used to report a Unit Attention for LUN Inventory changed. N This error is used to report a Unit Attention for the case where mode parameters were restored from defaults. Y The LUN Security Utility cannot add any more associations for new Principals because the supported limit for Principals has been reached. N A command to a backend device failed in an expected manner, so that logging is not required. N A command to a backend device failed with sense data indicating an unexpected error. N A command to a backend device failed due to an error that does not include sense data from the device. Y LUN Security Authoriztion failed - Host attempted to perform an operation on a LUN without having an appropriate access permission. N Phantom enclosure is a collection of disks with no physical slot mapping. Ideally there should not be any disk in phatom enclosure Y A Journal Manager Buffer Write has failed. Resilient map updates have not been posted to disk. FUA write failures may result from this condition Y A Journal Manager Stage Write has failed. Resilient map updates have not been posted to disk. FUA write failures may result from this condition M Description fg F ai l? N The frequency distribution table used to locate recently modified blocks was found to be inconsistent. This is indicative of a firmware problem. This problem is self correcting. N The firmware made a decision to automatically fail a disk device due to its accumulated error history. N During startup a disk stamp newer than the NVRAM committed stamp copy was found. This indicates the volume set attached successfully to a different controller and this VS related NVRAM is not valid. N During startup a quorum of the drives belonging to the volume set the NVRAM stamp were not present.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

Event
Number
(dec/hex)
Event
Name
Logged?
Predictive
Maintenance
Implication
Suspected
Components
Mfg Fail?
Description
parameters stored there will probably revert to their
default values.
122/0x7a
Hardware error prevents
successful command
completion
Y
None of these are
allowed
Unknown
Y
The command failed because a required access to
hardware failed and was either not retried or was
retried unsuccessfully.
123/0x7b
Host Port Behavior Table
overflow
Y
None of these are
allowed
Unknown
Y
An attempt was made to add a new entry to the host
port behavior table but no unused entry was
available.
An existing entry must be deleted to
make room for the new entry.
124/0x7c
Sequencer error injection error
N
These only occur
in internal testing
Unknown
Y
This error is used for a variety of purposes when
injecting errors in sequencer module tests.
125/0x7d
Test mode is required for this
command
N
These only occur
in internal testing
Unknown
Y
The command that was received is only allowed
when the test mode flag in the personality is true.
126/0x7e
Subsystem LUN configuration
changed UA
N
Ignore
None
N
This error is used to report a Unit Attention for LUN
Inventory changed.
127/0x7f
Mode parameters were restored
from defaults UA
N
Ignore
None
N
This error is used to report a Unit Attention for the
case where mode parameters were restored from
defaults.
128/0x80
Limit to supported number of
Principals has been reached
Y
Ignore - Remove
unwanted
associations from
Security map
None
Y
The LUN Security Utility cannot add any more
associations for new Principals because the
supported limit for Principals has been reached.
129/0x81
Disk Interface Error - no
logging
N
N.A.
None
N
A command to a backend device failed in an
expected manner, so that logging is not required.
130/0x82
Disk Interface Error
Y
N.A.
None
N
A command to a backend device failed with sense
data indicating an unexpected error.
131/0x83
Disk Interface Command
Failed
Y
N.A.
None
N
A command to a backend device failed due to an
error that does not include sense data from the
device.
132/0x84
Host is not authorized to access
LUN
Y
Ignore - Host
doesn’t have
permission to
access LUN
None
Y
LUN Security Authoriztion failed - Host attempted
to perform an operation on a LUN without having
an appropriate access permission.
133/0x85
Cannot identify a FRU in
phatom enclosure with id 0xff
Y
Ignore - Cannot
identify FRU in
phantom
enclosure
None
N
Phantom enclosure is a collection of disks with no
physical slot mapping. Ideally there should not be
any disk in phatom enclosure
134/0x86
Journal Manager Buffer Write
Failed
Y
N.A.
Journal
Manager
Y
A Journal Manager Buffer Write has failed.
Resilient map updates have not been posted to disk.
FUA write failures may result from this condition
135/0x87
Journal Manager Stage Write
Failed
Y
N.A.
Journal
Manager
Y
A Journal Manager Stage Write has failed. Resilient
map updates have not been posted to disk. FUA
write failures may result from this condition
Event
Event
E
v
e
nt
Predictive
Suspected
M
fg
Description
Number
Name
L
o
g
g
e
d
?
Maintenance
Components
F
ai
l?
(dec/hex)
Implication
256/0x100
Access Time Count Error
Y
Ignore.
None
N
The frequency distribution table used to locate
recently modified blocks was found to be
inconsistent.
This is indicative of a firmware
problem.
This problem is self correcting.
257/0x101
Disk Drive Placed In Failed
State
Y
Single
Occurrance
Disk Drive,
Controller,
Back End FC
Link
N
The firmware made a decision to automatically fail
a disk device due to its accumulated error history.
258/0x102
NVRAM Image Out Of Date
Y
Ignore - Operator
activity
None
N
During startup a disk stamp newer than the
NVRAM committed stamp copy was found.
This
indicates the volume set attached successfully to a
different controller and this VS related NVRAM is
not valid.
259/0x103
No Quorum For Disk Set
Access
Y
Ignore - Operator
activity or
None
N
During startup a quorum of the drives belonging to
the volume set the NVRAM stamp were not present.