HP Kayak PC Workstation Service Handbook PC Workstations and Accessories 4th Edition June 2000 - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 2
6 HP Kayak XM600 Desktop PC Workstations Models and Accessories Product Cache Number1 Memory Std. RAM Hard Drive Video Controller Multi-media LAN HP Kayak XM600 7/xxx PC Workstation HP Kayak XM600 500 MHz - 100 MHz FSB2 (CPL: 01/2000 ) D9531N and D9531T D9532N3 and D9532T3 Pentium® III with - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 3
HP Kayak XM600 Desktop PC Workstations Product Cache Number1 Memory Std. RAM Hard Drive Video Controller Multi-media LAN HP Kayak XM600 533 MHz - 133 MHz FSB (CPL: 01/2000 ) D8350N3 and D8350T3 D9535N and D9535T Pentium III with i256 KB of L2 cache memory 128 MB 10 GB SDRAM Ultra 100 MHz - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 4
HP Kayak XM600 Desktop PC Workstations Product Cache Number1 Memory Std. RAM Hard Drive Video Controller Multi-media LAN HP Kayak XM600 667 MHz -133 MHz FSB (CPL: 01/2000 ) D9548N and D9548T Pentium III with i256 KB of L2 cache memory 128 MB 15 GB SDRAM Ultra 100 MHz ATA/66 non-ECC 7.2 krpm - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 5
SCSI Matrox Millennium G250 8 MB SGRAM video memory fitted HP 10/100 BT PCI All models are supplied with a 1.44 MB Floppy Disk Drive, an integrated IDE controller, and an integrated audio chip on the system board. 6-4 HP Kayak XM600 Desktop PC Workstations Medium-Profile Desktop PC Workstations - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 6
Kayak XM600 Desktop PC Workstations Product Cache Number1 Memory Std. RAM Hard Drive Video Controller Multi-media LAN D8488AV D8808AV HP Kayak XM600 (CPL: 01/2000 ) V-Exp Base Model IDE V-Exp Base Model SCSI 1. Unless otherwise mentioned, the operating system for the HP Kayak XM600 Desktop - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 7
HP Kayak XM600 Desktop PC Workstations Supported Accessories Memory Upgrades RDRAM 64 MB non-ECC main memory RDRAM 128 MB non-ECC main memory RDRAM 256 MB non-ECC main memory RDRAM 64 MB ECC main memory RDRAM 128 MB ECC main memory RDRAM 256 MB ECC main memory SDRAM1 64 MB 100 MHz non-ECC main - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 8
Video Memory 8 MB SGRAM SODIMM for Matrox G200/250 AGP graphics card D9527A Audio and Multimedia Labtech amplified speakers (10 WRMS) (single) Labtech amplified speakers (4 WRMS) (single) Standard headset D4545A D6861A D8387A Medium-Profile Desktop PC Workstations HP Kayak XM600 Desktop PC - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 9
HP Kayak XM600 Desktop PC Workstations Miscellaneous USB Hub accessory kit D6804A 1. All models shipped with SDRAM memory should be converted to RDRAM memory. Consult HP Support for further information. 2. Dual Processor Kits include: processor, voltage regulator module and heatsink. 3. NIC = - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 10
next boot. Retains CMOS memory. Clears CMOS memory at next boot. Enables User and System Administrator passwords. Clears the passwords at next boot. Selects the chassis type. OFF = Desktop. ON = Minitower NOTE: A limited number of early HP Kayak XM600 system boards have 20 configuration switches - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 11
a Dual Processor / Replacing a Processor HP Kayak XM600 Desktop PC Workstations are supplied with a Pentium III processor and an integrated VRM (Voltage Regulator Module) on the system board. A separate VRM is not required. Single processor models can be upgraded to dual processor systems by - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 12
HP Kayak XM600 Desktop PC Workstations The SDRAM Memory Expansion Card socket always contains a "RDRAM Terminator Module". Second RIMM module, or RDRAM Continuity Module if unused RDRAM Terminator Module First RIMM module Processor 2, or processor terminator card if unused Processor 1 System - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 13
HP Kayak XM600 Desktop PC Workstations Parts and Part Numbers 1b 1c 5 3 7 8 6 2b 4 2a 6 1 1d 2d 2c 1a 6-12 HP Kayak XM600 Desktop PC Workstations Medium-Profile Desktop PC Workstations - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 14
See system board parts list 6 4 Power supply unit 0950-3627 - 5 Processor connector termination card 6 SDRAM1 Memory Expansion Card 5064-9725 - 5065-0480 - 7 RDRAM Continuity Module D8660-63001 - 8 RDRAM Termination Module 5065-1281 - Medium-Profile Desktop PC Workstations HP Kayak XM600 - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 15
shipped with SDRAM memory should be converted to RDRAM memory. Consult HP Support for further information. 2. Should only be used in conjunction with an Elsa Synergy II AGP video card for dual monitor display. 6-14 HP Kayak XM600 Desktop PC Workstations Medium-Profile Desktop PC Workstations - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 16
be converted to RDRAM memory. Consult HP Support for further information. 6 Manuals and Documentation Description User's Guide - English only Part Number D8368-90001 Troubleshooting Guide Technical Reference Manual Online documentation can be downloaded from: http://www.hp.com/go/kayaksupport - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 17
HP Kayak XM600 Desktop PC Workstations Notes 6 6-16 HP Kayak XM600 Desktop PC Workstations Medium-Profile Desktop PC Workstations - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 18
If an error occurs during the POST, which prevents the PC Workstation from starting, and before the display device has been initialized, a series of beep codes are issued. Beep codes indicate that a fatal error has occurred and can be reported one after another if there is more than one detected - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 19
A Beep Codes for the HP Kayak XU800 Number of Beeps 1 2 3 4 5 6 7 8 Description The memory refresh circuitry is faulty. Parity error in the base memory (the first 64 KB block) of memory. Memory error. Clock error. Processor test error. Input/Output (I/O) error. The processor on the system board - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 20
replace the system board. Perform the following actions in this order: 1 Press F2 to enter the Setup program, then F9 to load the default BIOS settings. 2 Clear the CMOS. 3 Flash the BIOS. If the error still occurs, replace the system board. Replace the processor(s). Beep, POST, and Error Codes A-3 - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 21
/HP reseller that system board is defective. This can be caused by problems with the ROM on integrated video, an add-on video board or the ROM on a SCSI card. Inform reseller for the affected component. 1. Non-HP memory modules are not supported. Only HP memory modules should be used. A-4 Beep - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 22
are for all models before the HP Kayak XU800 and XM600 PC Workstations. Beep Pattern Beep Code 1-2-2-3 1-3-1-1 1-3-1-3 1-3-3-1 1-4-4-1 1-3-4-1 1-3-4-3 2-1-2-3 2-2-3-1 1-2 1 4-2-4-4 Numeric Code 16h 20h 22h 28h 30h 2Ch 2Eh 46h 58h 98h B4h / F4h Description BIOS ROM check-sum failure DRAM - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 23
A POST and Error Codes Notes A-6 Beep, POST, and Error Codes - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 24
floppy disk, then flashes the BIOS. However, it should be noted that during the flash process, the screen remains blank. MaxiLife will display a message on the LCD panel "RECOVERY MODE". 10 The recovery process is finished when there are four beeps. 11 Power off the PC Workstation. Remove the floppy - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 25
disk. The latest system BIOS (standard flash operation) can be downloaded from HP's Support Web site at: http://www.hp.com/go/kayaksupport. Then select HP Kayak XM600 PC Workstation. Instructions on updating the BIOS are supplied with the downloaded BIOS files and a BIOS flash utility (flash.txt - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 26
BIOS flash, Switch 9 (XA models) or 10 (XW and XA-s models) Down Position WARNING: WARNING: For Kayak XU Series 03xx, XA-s Series B 02xx and XA Series 05xx, a specific there is a much longer beep (approximately around 1 to 2 minutes). 7 Power off the computer. Press the power ON/OFF button (for - HP XM600 | hp kayak xm600 series 2, service handbook for desktop models - Page 27