Hitachi ic35l060avv207-0 Specifications - Page 198
Set Max Freeze Lock Feature = 04h
View all Hitachi ic35l060avv207-0 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 198 highlights
11.38.4 Set Max Freeze Lock (Feature = 04h) Command Block Output Registers Register 7 6 5 4 3 2 1 0 Data Feature 0 0 0 0 0 1 0 0 Sector Count Sector Number Cylinder Low Cylinder High Device/Head 1 - 1 D - - - - Command 1 1 1 1 1 0 0 1 Command Block Input Registers Register 7 6 5 4 3 2 1 0 Data Error see below Sector Count Sector Number Cylinder Low Cylinder High Device/Head 1 - 1 D - - - - Status see below Error Register 76543210 CRC UNC 0 IDN 0 ABT T0N AMN 00000V00 Status Register 7 6 5 4 3 2 10 BSY RDY DF DSC DRQ COR IDX ERR 0 V 0 - - 0 -V Figure 153. Set Max Freeze Lock (F9h) If the Set Max Freeze Lock command is immediately preceded by a Read Native Max Address command, this command is regarded as a Set Max Address command. The Set Max Freeze Lock command sets the device to Set_Max_Frozen state. After the completion of the command any subsequent Set Max commands are rejected. Commands disabled by Set Max Freeze Lock are the following: 1. Set Max Address 2. Set Max Set PASSWORD 3. Set Max Lock 4. Set Max Unlock Deskstar 180GXP hard disk drive specifications 184