TROUBLESHOOTING PROBLEM No Power/No Mist from Spout Peculiar Odor Excessive Noise White Dust Accumulation POSSIBLE CAUSE • Unit is not plugged in • No power at unit • Low water level • Unit is new • If unit is in use, the odor may be a dirty tank or old tank water • Unit is not level • Low water level • Hard water used • Demineralization Cartridge needs replacement SOLUTION • Plug unit in • Turn the Power/Mist knob clockwise to turn the power on • Check circuits and fuses or try a different outlet • Refill the tank with water • Open the water tank cap and keep it in a shady, cool place for 12 hours • Empty the old water, clean the tank and fill with clean water • Place unit on a flat, even surface • Check the water level. Refill the tank if the water is low • Use distilled water and a Demineralization Cartridge • Replace Demineralization Cartridge 10 FCC STATEMENT NOTE: This product has been tested and complies with the requirements for Federal Communication Commission, Part 18. Although this product is tested and complies with FCC, it may interfere with other devices. If this product is found to interfere with another device, separate the other device and this product. Conduct only the user maintenance found in this instruction manual. Other maintenance and servicing may cause harmful interference and can void the required FCC compliance. Industry Canada ICES-001 Compliance Label: CAN ICES-1/NMB-1 Caution: All servicing of this humidifier must be performed by authorized HoMedics service personnel only. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19

10
11
PROBLEM
POSSIBLE CAUSE
SOLUTION
No Power/No Mist from Spout
Unit is not plugged in
No power at unit
• Low water level
• Plug unit in
Turn the Power/Mist knob
clockwise to turn the
power on
Check circuits and fuses or
try a different outlet
Refill the tank with water
Peculiar Odor
• Unit is new
If unit is in use, the odor
may be a dirty tank or old
tank water
Open the water tank cap and
keep it in a shady, cool place
for 12 hours
Empty the old water,
clean the tank and fill
with clean water
Excessive Noise
Unit is not level
• Low water level
Place unit on a flat,
even surface
Check the water level. Refill
the tank if the water is low
White Dust Accumulation
• Hard water used
• Demineralization Cartridge
needs replacement
Use distilled water and a
Demineralization Cartridge
• Replace Demineralization
Cartridge
TROUBLESHOOTING
FCC STATEMENT
NOTE: This product has been tested and complies with the requirements for Federal Communication
Commission, Part 18. Although this product is tested and complies with FCC, it may interfere with other
devices. If this product is found to interfere with another device, separate the other device and this
product. Conduct only the user maintenance found in this instruction manual. Other maintenance and
servicing may cause harmful interference and can void the required FCC compliance.
Industry Canada ICES-001 Compliance Label: CAN ICES-1/NMB-1
Caution: All servicing of this humidifier must be performed by authorized HoMedics service
personnel only.