HoMedics WGNBPA-960BT User Manual - Page 22
Troubleshooting, Specifications - bluetooth pairing
View all HoMedics WGNBPA-960BT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
TROUBLESHOOTING If any abnormality arises during use, please check the following points: SYMPTOMS POSSIBLE CAUSES CORRECTION Unit does not turn on when the START/STOP button is pushed. EE measurement error symbol shown on display or the blood pressure value is displayed excessively low (or high). E1 error symbol shown on display. E2 error symbol shown on display. E3 error symbol shown on display. E4 - Data transmission error symbol shown on the display. EP error symbol shown on display. Batteries have run down. Replace them with four new "AA" alkaline batteries. Battery polarities (+/-) have been posi- Re-insert the batteries in the correct posi- tioned incorrectly. tions. See page 11. The UltraSoft™ Upper Arm Cuff has been Re-wrap the cuff properly so that it is posi- positioned on the arm incorrectly. tioned correctly. Take new measurement. Did you talk or move during measurement? Shaking of the arm with the cuff on. Air circuit abnormality. Cuff tube may not be plugged into monitor correctly. Inflation pressure exceeding 300 mmHg. Error determining measurement data. Keep arm steady during measurement. Measure again. Refer to "Measurement Procedure" instructions, see page 21. Check cuff connection. See page 18. Take new measurement. Switch the unit off and then turn back ON. Take new measurement. Re-wrap the cuff properly so that it is positioned correctly. Take new measurement. Bluetooth function is turned OFF, on your mobile device. Turn Bluetooth ON, on your mobile device, and try again. Bluetooth function is turned OFF, on the blood pressure monitor. Turn the Bluetooth function ON, on your blood pressure monitor (see page 15), then try again. Make sure Bluetooth is ON, on the mobile device and the blood pressure monitor, and try again. Mobile device does not pair with the blood pressure monitor. Requires compatible mobile device. This blood pressure monitor is compatible with mobile devices that are running iOS 5.0 or newer, or AndroidTM 4.3 and newer. For a complete list, go to www.walgreens.com/connectapp. The App on the mobile device is not open. Make sure the app is open on the mobile device, and try again. The blood pressure monitor and mobile device are out of transmitting range. Make sure the mobile device and blood pressure monitor are within the acceptable range of 32 feet (10 meters). Unexpected loss of electrical/ mechanical integrity. Make sure your last reading is stored in memory and the App is open and try again. See page 26. Remove batteries, re-insert, and try again. Return the device to your local distributor or importer. System Error. Remove batteries. After 1 minute, re-insert the batteries. Take new measurement. Note: If the unit still does not work, contact HoMedics Consumer Relations. Under no circumstance should you disassemble or attempt to repair the unit by yourself. Contact information for HoMedics Consumer Relations Department can be found on the warranty page. 41 SPECIFICATIONS Power Source: (4) 1.5V DC "AA" alkaline batteries or 6V DC AC adapter Measurement Method: Oscillometric Measurement Range: Pressure: 40~280 millimeters Mercury (mmHg) Pulse: 40~199 beats/minute Accuracy: Pressure: ±3 mmHg Pulse: ±5% of reading Pressure Sensor: Semi-conductor Inflation: Pump driven Deflation: Automatic Pressure release valve Memory Capacity: 120 memories for each User (240 total) Operation Temperature: 41°F~104°F (5°C ~40°C) Environment: Humidity: 15% ~ 93% RH Storage/Transportation Temperature: -13°F~158°F (-25°C~70°C) Environment: Humidity: Less Than 93% RH Weight: 0.74 lb (330 g) (without batteries) Arm Circumference: Ultrasoft™ Upper Arm Cuff Size: 9"- 17" (23-43cm) Dimensions: 4.65"(L) x 6.46"(W) x 1.89"(H) 118mm(L) x 164mm(W) x 48mm(H) Accessories: (4) "AA" alkaline batteries, 6V DC AC adapter, instruction manual, 1 arm cuff with tube Internally Powered equipment Type BF Equipment IP22- Degrees of protection provided by enclosures. Not suitable for use in presence of flammable anesthetic mixture with air, oxygen or nitrous oxide. Continuous operation with short-time loading. Follow instructions for use. Note: T hese specifications are subject to change without notice. 42