Automatic Trigger, Presentation Mode, Continuous Illumination Mode, Read Time-Out
View all Honeywell 3800G04-USBKITE manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Read Time-Out Use this selection to set a time-out (in milliseconds) of the imager's trigger when using serial commands to trigger the imager. Once the imager has timed out, you can activate the imager either by pressing the trigger or using a serial trigger command. After scanning the Read Time-Out bar code, set the time-out duration (from 0-300,000 milliseconds) by scanning digits from the inside back cover, then scanning Save. Default = 300,000. Read Time-Out Automatic Trigger The imager scans continuously at full power with illumination fully on. Automatic Trigger Presentation Mode Presentation Mode uses ambient light to detect bar codes. The LEDs are off for ambient conditions until a change occurs in the imager's field of view. Then the LEDS turn on automatically to read the code. If the light level in the room is not high enough, Presentation Mode may not work properly. Presentation Mode Continuous Illumination Mode If you have several bar codes that are close together, you may wish to have a continuous aiming beam on in order to properly aim the imager at one bar code. Scan the Continuous Illumination On bar code to program the imager for this capability. Once you have the aiming beam over the correct bar code, pull the trigger to read the code. Scan the Continuous Illumination Off bar code to turn off this feature. Continuous Illumination Mode On * Continuous Illumination Mode Off 3 - 4 3800g User's Guide