Honeywell 6151 Installation Guide - Page 4

‡K6206V1EŠ - keypad instructions

Page 4 highlights

SPECIFICATIONS Dimensions: 4-7/8"H x 6-1/4"W x 1"D Wiring Terminals: GM - + LY ZN1 Description Data In to Control Panel - Ground (12 VDC -) + 12 VDC Power Input Data Out from Control Panel + Wired Zone 1 - Wired Zone 1 LEGEND = - Note: The keypad will display "OC" and beep periodically when there is a fault that prevents data from reaching the keypad. Display: Fixed word LCD, backlit. Sounder: Piezo (fire alarm sound is loud, temporal pattern pulsed tone; burglary alarm sound is loud, continuous, dual tone). Voltage: +12 VDC Current: Alarm rating: 80mA (LCD backlight on, sounder on) Standby rating: 50mA (LCD backlight on, sounder off); 35mA (LCD backlight off, sounder off) The control panel determines whether LCD backlighting is on or off. When determining the capacity of the control panel's backup battery, use the following chart: If Backlighting is . . . Then . . . On steadily Use the 50mA current rating Off when keypad is Use the 35mA current inactive rating. REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION AND FOR LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 165 Eileen Way, Syosset, New York 11791 Copyright © 2006 Honeywell International Inc. www.honeywell.com/security ‡K6206V1EŠ K6206V1 6/06 Rev. B WWW.DIYWALWARMWFO.RUDM.ICOYM ALARMFORUM.COM

  • 1
  • 2
  • 3
  • 4

SPECIFICATIONS
Dimensions:
4-7/8"H x 6-1/4"W x 1"D
Wiring
Terminals:
Description
G
Data In to Control Panel
– Ground (12 VDC –)
+
+ 12 VDC Power Input
Y
Data Out from Control Panel
ZN1
+ Wired Zone 1
- Wired Zone 1
LEGEND
= -
Note
:
The
keypad
will
display
“OC”
and
beep
periodically when there is a fault that prevents
data from reaching the keypad.
Display:
Fixed word LCD, backlit.
Sounder:
Piezo (fire alarm sound is loud, temporal pattern
pulsed tone; burglary alarm sound is loud, continuous,
dual tone).
Voltage:
+12 VDC
Current:
Alarm rating: 80mA (LCD backlight on, sounder on)
Standby rating: 50mA (LCD backlight on, sounder off);
35mA (LCD backlight off, sounder off)
The
control
panel
determines
whether
LCD
backlighting is on or off. When determining the
capacity of the control panel’s backup battery, use the
following chart:
If Backlighting is . . .
Then . .
.
On steadily
Use the 50mA current
rating
Off
when
keypad
is
inactive
Use the 35mA current
rating.
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS
DEVICE IS USED FOR WARRANTY INFORMATION AND FOR LIMITATIONS OF THE ENTIRE ALARM
SYSTEM.
165 Eileen Way, Syosset, New York 11791
Copyright
© 2006 Honeywell International Inc.
www.honeywell.com/security
‡K6206V1EŠ
K6206V1
6/06
Rev. B