Honeywell CT87B Owner's Manual - Page 6

Wire the thermostat, Wiring Cross-reference - round thermostat

Page 6 highlights

CT87A,B,J ROUND® THERMOSTAT 6 Wire the thermostat 1. Use the wiring cross-reference table below to match each old thermostat wire with its corresponding terminal on the CT87 wallplate or subbase. See Fig. 8 through 13 wiring diagrams. Wiring Cross-reference Wire Label R, RH, 4, V Rc, R W, W1, H Y, Y1, M G, F B O See Fig. 13 Connect to CT87A R W Y See Fig. 9 Connect to Connect to CT87B CT87J RH R Rc W W Y Y G G B* O* P *Never attach wires to both the B and O terminals. 2. Strip the wire insulation as needed to fit the wires underneath the terminal screws (Fig. 7). Fig. 7. Fitting wires under the terminal screws. FOR STRAIGHT CONNECTION- STRIP 5/16 in. [8 mm] FOR WRAPAROUND CONNECTION- STRIP 7/16 in. [11 mm] BARRIER M1279 3. Loosen the terminal screws and slip each wire beneath its matching terminal. 4. Securely tighten the terminal screws. 5. Push any excess wire back into the wall. 69-0274-6 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

CT87A,B,J ROUNDfi THERMOSTAT
69-0274-6
6
Wire the thermostat
1.
Use the wiring cross-reference table below to match each old
thermostat wire with its corresponding terminal on the CT87 wallplate
or subbase.
See Fig. 8 through 13 wiring diagrams.
*Never attach wires to both the B and O terminals.
2.
Strip the wire insulation as needed to fit the wires underneath the ter-
minal screws (Fig. 7).
3.
Loosen the terminal screws and slip each wire beneath its matching
terminal.
4.
Securely tighten the terminal screws.
5.
Push any excess wire back into the wall.
Wiring Cross-reference
Wire Label
Connect to
CT87A
Connect to
CT87B
Connect to
CT87J
R, RH, 4, V
R
RH
R
Rc, R
Rc
W, W
1
, H
W
W
W
Y, Y
1
, M
Y
Y
Y
G, F
G
G
B
See Fig. 9
B*
O
O*
See Fig. 13
P
6
Fig. 7. Fitting wires under the terminal screws.
M1279
FOR STRAIGHT
CONNECTION—
STRIP 5/16 in. [8 mm]
FOR WRAPAROUND
CONNECTION—
STRIP 7/16 in. [11 mm]
BARRIER