No. of Service LED Blinks 13 Fault Description Tank failed to drain. Auto-Recoverable? No Steps to Fix (Performed Only By Professional HVAC Technician) CAUTION: Water in tank may be hot (>140°F [60°C]). 14 Heater failed to Yes, system will boil water. return to "Ready" if fault no longer exists in one hour. 15 No airflow sensed Yes, system will in supply duct. return to "Ready" if fault no longer exists in one hour. 17 Power to the wireless Yes, system will adapter overloaded. return to "Ready" if fault no longer exists in one hour. 18 Wireless Yes, system will communication return to "Ready" from wireless after one minute. adapter failed. Cleaning Tank was slow to N/A Required drain during last light automatic flush cycle is on. or 12-month cleaning interval time has expired. 1. Press the Drain button. 2. If tank fails to drain, wait for water in tank to cool. 3. Ensure tank water is cool. Once it is, follow tank cleaning steps under "Manual Cleaning Cycle" in manual. 4. Ensure drain tube is not pinched, clogged or blocked 5. Reassemble tank, reinstall tank and press the "GO" button to reset. 6. If tank fault persists, replace solenoid valve. (#50027997-001) 1. Follow the tank cleaning steps. "Manual Cleaning Cycle" 2. Ensure entire tank, heating element and reservoir area are clean. 3. Reassemble & reinstall tank 4. Press GO button to reset. 5. Ensure that there is 120 Vac at heating element terminals. 6. If fault returns, replace the TrueSTEAM 1. Ensure optional add-on air proving device is installed and wired correctly. 2. Unplug TrueSTEAM, and remove cover. 3. Ensure DIP switches are set correctly. (DIP 4 down, DIP 5 up.) 4. Reconnect cover and plug in TrueSTEAM. 5. Press and hold the Go button to clear the fault. 6. If the fault persists, replace the air proving device being used. 1. Verify wiring between TrueSTEAM and the wireless adapter. 2. Ensure DIP switches are set correctly. (DIP 3 up. Also DIP 4 up if TrueSTEAM R and C aren't wired.) 3. If the fault persists, replace the wireless adapter. 1. Verify wiring between TrueSTEAM and the wireless adapter. 2. Verify the Prestige control is operating correctly. 3. If the fault persists, replace wireless adapter and re-enroll connection to Prestige. Follow the tank cleaning steps. See "Manual Cleaning Cycle" on page 46. OPERATION AND SERVICE 56 TrueSTEAM Humidification System 69-2285-01