Programming You can program your thermostat to automatically lower and raise the temperature one or more times every 24 hours. Before Setting Your Program Lift thermostat flip-up cover and you'll find the 24-hour program dial. The slots on the program dial (Fig. 4) are for the program pins which can be inserted at ten-minute intervals. Three red and three blue program pins are included with your thermostat. The red pins start the high-temperature period; the blue pins start the low-temperature period. A heating program has been preprogrammed. A red pin is inserted at 6:00 a.m. for high temperature (comfort period); a blue pin is inserted at 10:00 p.m. for low temperature (energy saving period). Two additional sets of pins are located in the program pin storage area. You can set up to six temperature changes with the pins supplied. We recommend at least five hours for each energy savings period. 24-HOUR PROGRAM DIAL (GRAY AREA FOR NIGHT SETTINGS) FLIP-UP COVER PROGRAM PINS THERMOSTAT COVER PROGRAM PIN SLOT PROGRAM INDEX WHEEL TIME INDICATOR ARROW PROGRAM PIN STORAGE M7348 Fig. 4-Program components. 11 69-0563-2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

11
69-0563—2
Programming
You can program your thermostat to
automatically lower and raise the temperature
one or more times every 24 hours.
Before Setting Your Program
Lift thermostat flip-up cover and you’ll find
the 24-hour program dial. The slots on the
program dial (Fig. 4) are for the program pins
which can be inserted at ten-minute intervals.
Three red and three blue program pins are
included with your thermostat. The red pins start
the high-temperature period; the blue pins start
the low-temperature period. A heating program
has been preprogrammed. A red pin is inserted
at 6:00 a.m. for high temperature (comfort
period); a blue pin is inserted at 10:00 p.m. for
low temperature (energy saving period). Two
additional sets of pins are located in the program
pin storage area. You can set up to six tempera-
ture changes with the pins supplied. We
recommend at least five hours for each energy
savings period.
Fig. 4—Program components.
24-HOUR PROGRAM DIAL
(GRAY AREA FOR NIGHT SETTINGS)
FLIP-UP
COVER
PROGRAM
PINS
THERMOSTAT
COVER
PROGRAM
PIN SLOT
PROGRAM INDEX WHEEL
TIME INDICATOR ARROW
PROGRAM
PIN STORAGE