Honeywell Q682 Owner's Manual - Page 18
Timer does not run.
View all Honeywell Q682 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Troubleshooting (continued) Problem Timer is losing time (continued). Check Action - high limit control. If clock powered through system transformer, power to clock and equipment may be Off on safety. Wire separate transformer to power clock. Timer does not run. - filter. May be clogged. Safety limit on equipment may cut off power to system. - voltage across the C and R terminals. Replace filter and reset clock. Remove the thermostat from the wallplate or subbase, and measure the voltage. Refer to page 19 for cause and action. (continued) 18 69-0563-2
18
69-0563—2