Function 6: Auxiliary heat cycle rate - system setup cycle rate
View all Honeywell RTH3100C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Installation Guide Function 6: Auxiliary heat cycle rate Setup 65 Press to change setting. Press the t button to select your auxiliary heating system and optimize its operation: 5 For gas or oil furnaces of less than 90% efficiency 1 For steam or gravity systems 3 For hot water systems & furnaces of over 90% efficiency 9 For electric furnaces When finished, press to advance to the next function. 16
Installation Guide
1ยด
Setup
6
5
Press to change setting.
When finished, press
to advance to the next
function.
Press the
t
button to select your auxiliary
heating system and optimize its operation:
5
For gas or oil furnaces of less than 90%
efficiency
1
For steam or gravity systems
3
For hot water systems & furnaces of over 90%
efficiency
9
For electric furnaces