Programming Thermostat Initial Powerup When the thermostat is first powered up (or after eight hours of continuous power loss), the display blinks for two seconds and then undergoes a self-test - while 00E displays for about 15 seconds. This is followed by the display flashing (1:00 PM); the internal checkout is complete and the thermostat is ready to be programmed. To verify that the thermostat is turning on the baseboard heater, press the (+) key until the setpoint displayed exceeds the room temperature. The (°) symbol is flashing. Feel for warmth in the area close to the heating element; the unit should be starting to generate heat. Press and hold the Prog key to return the thermostat to the Run mode. Factory Set Programming The thermostat defaults to a normal nonprogrammable thermostat at power-up, indicated with Hold appearing in the display. Pressing the Prog key once enters the programming mode. The thermostat is preset with a factory set schedule for 7 days, see Table 1. Table 1. Preset Factory Schedule for 7-days. Event WAKE LEAVE RETURN SLEEP Time 6:00 AM 8:00 AM 6:00 PM 10:00 PM Temperature 70°F (21°C) 61°F (16°C) 70°F (21°C) 61°F (16°C) 5 69-1396-2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

5
69-1396—2
Programming Thermostat
Initial Powerup
When the thermostat is first powered up (or
after eight hours of continuous power loss),
the display blinks for two seconds and then
undergoes a self-test — while 00E displays
for about 15 seconds.
This is followed by the display flashing
(1:00 PM); the internal checkout is
complete and the thermostat is ready to be
programmed.
To verify that the thermostat is turning on
the baseboard heater, press the (+) key
until the setpoint displayed exceeds the
room temperature.
The (°) symbol is flashing. Feel for warmth
in the area close to the heating element;
the unit should be starting to generate heat.
Press and hold the Prog key to return the
thermostat to the Run mode.
Factory Set Programming
The thermostat defaults to a normal non-
programmable thermostat at power-up,
indicated with Hold appearing in the
display. Pressing the Prog key once enters
the programming mode. The thermostat is
preset with a factory set schedule for 7
days, see Table 1.
Table 1. Preset Factory Schedule
for 7-days.
Event
Time
Temperature
WAKE
6:00 AM
70°F (21°C)
LEAVE
8:00 AM
61°F (16°C)
RETURN
6:00 PM
70°F (21°C)
SLEEP
10:00 PM
61°F (16°C)