English: Page 1 • Français: Page 6 • Español: Página 11 Subbase and base installation 1. Pull wires through wire hole. Position coverplate on wall, level and mark hole positions. 2. Drill holes (3/16" for drywall, 7/32" for plaster) and tap in supplied wall anchors. 3. Pull wire through coverplate and subbase, position over anchors, then insert and tighten mounting screws. Check level if desired. 4. Apply the large-print labels to the coverplate, matching the labels on the subbase. Coverplate Large-print subbase switch labels Subbase Wiring 1. Loosen screw terminals, insert wires into terminal block, then re-tighten screws. 2. Push excess wire back into the wall opening. 3. Plug the wall opening with nonflammable insulation to prevent drafts from affecting thermostat operation. Terminal Designations W Heat relay. Y Compressor contactor. G Fan relay. O Heat pump changeover valve energized in cooling. Rc Cooling power. Connect to secondary side of cooling system transformer. R Heating power. Connect to secondary side of heating system transformer. B Heat pump changeover valve energized in heating. E F G R W Rc Y O B NOTES R & Rc terminals In single-transformer system, leave metal jumper in place between R & Rc. Remove metal jumper if two-transformer system. Heat pump systems If wiring to a heat pump, use a small piece of wire (not supplied) to connect terminals W and Y. Wire specifications Use 18- to 22-gauge thermostat wire. Shielded cable is not required. 3 69-1840EFS-03

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

English:
Page 1 •
Français:
Page 6 •
Español:
Página 11
3
69-1840EFS—03
1. Pull wires through wire
hole. Position coverplate
on wall, level and mark hole
positions.
2.
Drill holes (3/16” for drywall,
7/32” for plaster) and tap in
supplied wall anchors.
3.
Pull wire through coverplate
and subbase, position over
anchors, then insert and
tighten mounting screws.
Check level if desired.
4.
Apply the large-print labels
to the coverplate, matching
the labels on the subbase.
1.
Loosen screw terminals, insert wires
into terminal block, then re-tighten
screws.
2.
Push excess wire back into the wall
opening.
3.
Plug the wall opening with
nonflammable insulation to prevent
drafts from affecting thermostat
operation.
Terminal Designations
W
Heat relay.
Y
Compressor contactor.
G
Fan relay.
O
Heat pump changeover valve
energized in cooling.
Rc
Cooling power. Connect to
secondary side of cooling system
transformer.
R
Heating power. Connect to
secondary side of heating system
transformer.
B
Heat pump changeover valve
energized in heating.
Wiring
NOTES
R & Rc terminals
In single-transformer system, leave metal
jumper in place between
R
&
Rc
. Remove
metal jumper if two-transformer system
.
Heat pump systems
If wiring to a heat pump, use a small piece
of wire (not supplied) to connect terminals
W
and
Y
.
Wire specifications
Use 18- to 22-gauge thermostat wire.
Shielded cable is not required.
R
G
W
Y
B
Rc
O
E
F
Coverplate
Subbase
Large-print
subbase switch
labels
Subbase and base installation