Page 4 highlights

T87N Easy-To-SeeTM • Owner's Manual Fan operation settings Fan operation settings: F: For gas or oil heating systems, leave the fan operation switch in this factory-set position (for systems that control the fan in E a call for heat). F E: Change the switch to this setting for heat pump or electric heat systems. (This setting is for systems that allow the thermostat to control the fan in a call for heat, if a fan wire is connected to the G terminal.) Cycle rate settings Move the cycle rate switches to the proper setting for your system (see table below). Thermostat mounting Coverplate and subbase Heating System Steam or gravity (1 CPH) High efficiency warm air (90%+), hot water, or heat pump (3 CPH) Gas or oil warm air (factory setting) (5 CPH) Electric warm air (9 CPH) Switch 1 On Off Off On Switch 2 On On Off Off Align the slots on the base with tabs on the thermostat, then push gently until the thermostat snaps into place. Thermostat 69-1840EFS-03 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

T87N Easy-To-See
TM
• Owner's Manual
69-1840EFS—03
4
Fan operation settings:
F:
For
gas or oil heating systems, leave
the fan operation switch in this factory-set
position (for systems that control the fan in
a call for heat).
E:
Change the switch to this setting for
heat
pump or electric heat
systems. (This setting
is for systems that allow the thermostat
to control the fan in a call for heat, if a fan
wire is connected to the G terminal.)
Align the slots on the base with tabs on the
thermostat, then push gently until the
thermostat snaps into place.
E
F
Fan operation settings
Cycle rate settings
Thermostat mounting
Thermostat
Coverplate
and subbase
Heating System
Switch 1
Switch 2
Steam or gravity (1 CPH)
On
On
High efficiency warm air
Off
On
(90%+), hot water, or
heat pump (3 CPH)
Gas or oil warm air
Off
Off
(factory setting) (5 CPH)
Electric warm air (9 CPH)
On
Off
Move the cycle rate switches
to the proper setting for your
system (see table below).